836 research outputs found

    Low frequency noise due to magnetic inhomogeneities in submicron FeCoB/MgO/FeCoB magnetic tunnel junctions

    Full text link
    We report on room temperature low frequency noise due to magnetic inhomogeneities/domain walls (MI/DWs) in elliptic submicron FeCoB/MgO/FeCoB magnetic tunnel junctions with an area between 0.0245 and 0.0675{\mu}m2. In the smaller area junctions we found an unexpected random telegraph noise (RTN1), deeply in the parallel state, possibly due to stray field induced MI/DWs in the hard layer. The second noise source (RTN2) is observed in the antiparallel state for the largest junctions. Strong asymmetry of RTN2 and of related resistance steps with current indicate spin torque acting on the MI/DWs in the soft layer at current densities below 5x10^5 A/cm2.Comment: 12 pages, 4 figure

    Motion Correction of Whole-Body PET Data with a Joint PET-MRI Registration Functional

    Get PDF
    Respiratory motion is known to degrade image quality in PET imaging. The necessary acquisition time of several minutes per bed position will inevitably lead to a blurring effect due to organ motion. A lot of research has been done with regards to motion correction of PET data. As full-body PET-MRI became available recently, the anatomical data provided by MRI is a promising source of motion information. Current PET-MRI-based motion correction approaches, however, do not take into account the available information provided by PET data. PET data, though, may add valuable additional information to increase motion estimation robustness and precision.In this work we propose a registration functional that is capable of performing motion detection in gated data of two modalities simultaneously. Evaluation is performed using phantom data. We demonstrate that performing a joint registration of both modalities does improve registration accuracy and PET image quality.<br

    The Energy Materials in-Situ Laboratory Berlin (EMIL) at BESSY II

    Get PDF
    The Helmholtz Center Berlin (HZB) and the Max-Planck Society (MPG) strengthen their research in renewable energies with the implementation of the joint Energy Material in-Situ Lab Berlin (EMIL) at the third generation light source BESSY II. The new facility is dedicated to the in-situ and in-system x-ray analysis of materials and devices for photovoltaic applications, (photo-) catalytic processes, energie conversion and storage. To obtain a comprehensive understanding of the involved materials, spectroscopic methods with x-rays from the soft- up to the hard x-ray regime reveal an almost complete picture of their chemical and electronic properties. The contribution presents the layout of the x-ray beamlines and their performance in terms of photon flux, energy resolution and spot sizes

    Systematic evaluation of 99mTc-tetrofosmin versus 99mTc-sestamibi to study murine myocardial perfusion in small animal SPECT/CT

    Full text link
    Background: The “back-translation” of clinically available protocols to measure myocardial perfusion to preclinical imaging in mouse models of human disease is attractive for basic biomedical research. With respect to singlephoton emission computed tomography (SPECT) approaches, clinical myocardial perfusion imaging protocols are established with different 99mTc-labeled perfusion tracers; however, studies evaluating and optimizing protocols for these tracers in high-resolution pinhole SPECT in mice are lacking. This study aims at evaluating two clinically available 99mTc-labeled myocardial perfusion tracers (99mTc-sestamibi vs. 99mTc-Tetrofosmin) in mice using four different imaging protocols. Methods: Adult C57BL/6 male mice were injected with 99mTc-sestamibi (MIBI) or 99mTc-Tetrofosmin (TETRO) (4 MBq/g body weight) either intravenously through the tail vein (n = 5) or retroorbitally (n = 5) or intraperitoneally (i. p.) under anesthesia (n = 3) or i.p. in an awake state (n = 3) at rest. Immediately after injection, a multi-frame singlephoton emission computed tomography/computed tomography (SPECT/CT) acquisition was initiated with six subsequent time frames of 10 min each. Reconstructed images of the different protocols were assessed and compared by visual analysis by experts and by time-activity-curves generated from regions-of-interest for various organs (normalized uptake values). Results: Visually assessing overall image quality, the best image quality was found for MIBI for both intravenous injection protocols, whereas TETRO only had comparable image quality after retroorbital injections. These results were confirmed by quantitative analysis where left ventricular (LV) uptake of MIBI after tail vein injections was found significantly higher for all time points accompanied with a significantly slower washout of 16% for MIBI vs. 33% for TETRO (p = 0.009) from 10 to 60 min post injection (PI). Interestingly, LV washout from 10 to 60 min PI was significantly higher for TETRO when applied by tail vein injections when compared to retroorbital injections (22%, p = 0.008). However, liver uptake was significant and comparable for both tracers at all time points. Radioactivity concentration in the lungs was negligible for all time points and both tracers. Conclusion: Intravenous MIBI injection (both tail vein and retroorbital) results in the best image quality for assessing myocardial perfusion of the murine heart by SPECT/CT. TETRO has a comparable image quality only for the retroorbital injection route

    Seebeck Effect in Magnetic Tunnel Junctions

    Full text link
    Creating temperature gradients in magnetic nanostructures has resulted in a new research direction, i.e., the combination of magneto- and thermoelectric effects. Here, we demonstrate the observation of one important effect of this class: the magneto-Seebeck effect. It is observed when a magnetic configuration changes the charge based Seebeck coefficient. In particular, the Seebeck coefficient changes during the transition from a parallel to an antiparallel magnetic configuration in a tunnel junction. In that respect, it is the analog to the tunneling magnetoresistance. The Seebeck coefficients in parallel and antiparallel configuration are in the order of the voltages known from the charge-Seebeck effect. The size and sign of the effect can be controlled by the composition of the electrodes' atomic layers adjacent to the barrier and the temperature. Experimentally, we realized 8.8 % magneto-Seebeck effect, which results from a voltage change of about -8.7 {\mu}V/K from the antiparallel to the parallel direction close to the predicted value of -12.1 {\mu}V/K.Comment: 16 pages, 7 figures, 2 table

    SPECT- and PET-Based Approaches for Noninvasive Diagnosis of Acute Renal Allograft Rejection

    Full text link
    Molecular imaging techniques such as single photon emission computed tomography (SPECT) or positron emission tomography are promising tools for noninvasive diagnosis of acute allograft rejection (AR). Given the importance of renal transplantation and the limitation of available donors, detailed analysis of factors that affect transplant survival is important. Episodes of acute allograft rejection are a negative prognostic factor for long-term graft survival. Invasive core needle biopsies are still the “goldstandard” in rejection diagnostics. Nevertheless, they are cumbersome to the patient and carry the risk of significant graft injury. Notably, they cannot be performed on patients taking anticoagulant drugs. Therefore, a noninvasive tool assessing the whole organ for specific and fast detection of acute allograft rejection is desirable. We herein review SPECT- and PET-based approaches for noninvasive molecular imaging-based diagnostics of acute transplant rejection

    EMIL The energy materials in situ laboratory Berlin a novel characterization facility for photovoltaic and energy materials

    Get PDF
    A knowledge based approach towards developing a new generation of solar energy conversion devices requires a fast and direct feedback between sophisticated analytics and state of the art processing test facilities for all relevant material classes. A promising approach is the coupling of synchrotron based X ray characterization techniques, providing the unique possibility to map the electronic and chemical structure of thin layers and interface regions with relevant in system in situ sample preparation or in operando analysis capabilities in one dedicated laboratory. EMIL, the Energy Materials In situ Laboratory Berlin, is a unique facility at the BESSY II synchrotron light source. EMIL will be dedicated to the in system, in situ, and in operando X ray analysis of materials and devices for energy conversion and energy storage technologies including photovoltaic applications and photo electrochemical processes. EMIL comprises up to five experimental end stations, three of them can access X rays in an energy range of 80 eV 10 keV. For example, one key setup of EMIL combines a suite of advanced spectroscopic characterization tools with industry relevant deposition facilities in one integrated ultra high vacuum system. These deposition tools allow the growth of PV devices based on silicon, compound semiconductors, hybrid heterojunctions, and organo metal halide perovskites on up to 6 sized substrates. EMIL will serve as a research platform for national and international collaboration in the field of photovoltaic photocatalytic energy conversion and beyond. In this paper, we will provide an overview of the analytic and material capabilities at EMIL

    Determination of partial photoionisation cross sections of methyl bromide in the first autoionisation range by use of spin polarisation photoelectron spectroscopy

    Get PDF
    Schäfers F, Baig MA, Heinzmann U. Determination of partial photoionisation cross sections of methyl bromide in the first autoionisation range by use of spin polarisation photoelectron spectroscopy. Journal of Physics B: Atomic, Molecular and Optical Physics. 1983;16(1):L1-L6.Using recent experimental data on photoelectron spin polarisation combined with the high-resolution spectrum of methyl bromide, which has also been recently reported, the partial photoionisation cross sections for the ionisation of CH3Br from the 4 pi ground-state orbital into the energy degenerate continua epsilon sigma , epsilon pi and epsilon delta have been determined separately. Quantitative results, obtained for the autoionising resonances between 116 and 118 nm, are reported and discussed

    VIPAR, a quantitative approach to 3D histopathology applied to lymphatic malformations.

    Get PDF
    BACKGROUND: Lack of investigatory and diagnostic tools has been a major contributing factor to the failure to mechanistically understand lymphedema and other lymphatic disorders in order to develop effective drug and surgical therapies. One difficulty has been understanding the true changes in lymph vessel pathology from standard 2D tissue sections. METHODS: VIPAR (volume information-based histopathological analysis by 3D reconstruction and data extraction), a light-sheet microscopy-based approach for the analysis of tissue biopsies, is based on digital reconstruction and visualization of microscopic image stacks. VIPAR allows semiautomated segmentation of the vasculature and subsequent nonbiased extraction of characteristic vessel shape and connectivity parameters. We applied VIPAR to analyze biopsies from healthy lymphedematous and lymphangiomatous skin. RESULTS: Digital 3D reconstruction provided a directly visually interpretable, comprehensive representation of the lymphatic and blood vessels in the analyzed tissue volumes. The most conspicuous features were disrupted lymphatic vessels in lymphedematous skin and a hyperplasia (4.36-fold lymphatic vessel volume increase) in the lymphangiomatous skin. Both abnormalities were detected by the connectivity analysis based on extracted vessel shape and structure data. The quantitative evaluation of extracted data revealed a significant reduction of lymphatic segment length (51.3% and 54.2%) and straightness (89.2% and 83.7%) for lymphedematous and lymphangiomatous skin, respectively. Blood vessel length was significantly increased in the lymphangiomatous sample (239.3%). CONCLUSION: VIPAR is a volume-based tissue reconstruction data extraction and analysis approach that successfully distinguished healthy from lymphedematous and lymphangiomatous skin. Its application is not limited to the vascular systems or skin. FUNDING: Max Planck Society, DFG (SFB 656), and Cells-in-Motion Cluster of Excellence EXC 1003
    corecore