    Improvements in design and fitness evaluation of above ground steel storage tanks

    Get PDF
    Above ground steel storage tanks are widely used to store liquids in a variety of industries. The design and fitness for service procedures for such tanks are a concern for international standards and need to be continually improved upon to ensure better safety and serviceability. Several important aspects about tank design and assessment are studied in this thesis. The bottom plate material near the shell to bottom joint in the tank is generally in plastic range. It is a critical failure point in many modes of tank failure. The effect of increasing the bottom plate projection length at this joint for tanks with rigid ring wall foundations is studied both theoretically and numerically. A theoretical beam model is validated using finite element analysis (FEA) and extended to determine the length of bottom plate projection needed for maximum effect. The formation of plastic hinges in the bottom plate on the inside and outside of this joint is discussed in detail using FEA. Tanks operating at elevated temperatures (200゚F to 500゚F) need to consider additional stresses due to thermal expansions and restraints from the tank shell and bottom plate interactions. The frictional forces from the foundation cause significant stresses at the tank bottom. The design guidelines by API 650 standard address this issue using a factor named ‘C’ that defines the ratio of actual expansion against free expansion of the tank bottom. At present, an empirical range of ‘C’ values (0.25 – 1.0) is allowed without clear guidelines for selecting a suitable value. This thesis evaluates the current procedure and suggests an alternate method by incorporating the friction coefficient directly in the stress equations, instead of the C-factor. The fill/draw down cycle of the stored liquid could lead to low cycle fatigue near shell to bottom joint. The peak alternating stress (strain) at this location determines the fatigue life of the tank. The widely used API 650 procedure employs beam on elastic foundation theory to determine the fatigue life for all tanks. The thesis shows that this is incorrect for tanks on concrete ring wall. The appropriateness of using this theory is studied and an alternative beam model is proposed. It is verified using FEA. Damage due to corrosion in the form of local thin area (LTA) is a widespread problem in storage tanks. Fitness for service (FFS) methods are quantitative engineering evaluations used to demonstrate the structural integrity of an in-service tank containing damage like LTA and make run, repair or replace decisions. The mα-tangent method is a simplified limit load procedure that can be used for such FFS evaluations. This thesis uses a modified reference volume for mα-tangent method applied to tanks and reports initial results for FFS evaluations. The study also finds that for large cylinders like tanks with very high R/t ratio, the circumferential decay lengths will be smaller than those previously reported ( 2.5 Rt rather than 6.3 Rt )

    Corrosion behavior of zirconia in acidulated phosphate fluoride

    Full text link
    ABSTRACT Objective The corrosion behavior of zirconia in acidulated phosphate fluoride (APF) representing acidic environments and fluoride treatments was studied. Material and Methods Zirconia rods were immersed in 1.23% and 0.123% APF solutions and maintained at 37°C for determined periods of time. Surfaces of all specimens were imaged using digital microscopy and scanning electron microscopy (SEM). Sample mass and dimensions were measured for mass loss determination. Samples were characterized by powder X-ray diffraction (XRD) to detect changes in crystallinity. A biosensor based on electrochemical impedance spectroscopy (EIS) was used to detect ion dissolution of material into the immersion media. Results Digital microscopy revealed diminishing luster of the materials and SEM showed increased superficial corrosion of zirconia submerged in 1.23% APF. Although no structural change was found, the absorption of salts (sodium phosphate) onto the surface of the materials bathed in 0.123% APF was significant. EIS indicated a greater change of impedance for the immersion solutions with increasing bathing time. Conclusion Immersion of zirconia in APF solutions showed deterioration limited to the surface, not extending to the bulk of the material. Inferences on zirconia performance in acidic oral environment can be elucidated from the study

    Corrosion behavior of zirconia in acidulated phosphate fluoride

    No full text
    ABSTRACT Objective The corrosion behavior of zirconia in acidulated phosphate fluoride (APF) representing acidic environments and fluoride treatments was studied. Material and Methods Zirconia rods were immersed in 1.23% and 0.123% APF solutions and maintained at 37°C for determined periods of time. Surfaces of all specimens were imaged using digital microscopy and scanning electron microscopy (SEM). Sample mass and dimensions were measured for mass loss determination. Samples were characterized by powder X-ray diffraction (XRD) to detect changes in crystallinity. A biosensor based on electrochemical impedance spectroscopy (EIS) was used to detect ion dissolution of material into the immersion media. Results Digital microscopy revealed diminishing luster of the materials and SEM showed increased superficial corrosion of zirconia submerged in 1.23% APF. Although no structural change was found, the absorption of salts (sodium phosphate) onto the surface of the materials bathed in 0.123% APF was significant. EIS indicated a greater change of impedance for the immersion solutions with increasing bathing time. Conclusion Immersion of zirconia in APF solutions showed deterioration limited to the surface, not extending to the bulk of the material. Inferences on zirconia performance in acidic oral environment can be elucidated from the study

    Titanium Corrosion Mechanisms in the Oral Environment: A Retrieval Study

    No full text
    Corrosion of titanium dental implants has been associated with implant failure and is considered one of the triggering factors for peri-implantitis. This corrosion is concerning, because a large amount of metal ions and debris are generated in this process, the accumulation of which may lead to adverse tissue reactions in vivo. The goal of this study is to investigate the mechanisms for implant degradation by evaluating the surface of five titanium dental implants retrieved due to peri-implantitis. The results demonstrated that all the implants were subjected to very acidic environments, which, in combination with normal implant loading, led to cases of severe implant discoloration, pitting attack, cracking and fretting-crevice corrosion. The results suggest that acidic environments induced by bacterial biofilms and/or inflammatory processes may trigger oxidation of the surface of titanium dental implants. The corrosive process can lead to permanent breakdown of the oxide film, which, besides releasing metal ions and debris in vivo, may also hinder re-integration of the implant surface with surrounding bone