17 research outputs found
Clinical value of thyrotropin receptor antibodies in patients with GravesŹ¹ orbitopathy/ophthalmopathy
Graves-ova orbitopatija (GO) je multifaktorska autoimuna bolest, joÅ” uvek nepotpuno
istražene etiologije i patogeneze. Osnovu ove patologije Äini inflamatorni poremeÄaj orbite.
ObiÄno se javlja u sklopu autoimunih bolesti tiroidne žlezde (AITB), prvenstveno Graves-ove
bolesti (GB), meÄutim poznati su sluÄajevi njene izolovane pojave u odsustvu tiroidnih
abnormalnosti. Graves-ova orbitopatija znaÄajno remeti svakodnevne aktivnosti, funkciju vida i
fiziÄki izgled pacijenata, a u najtežim sluÄajevima može dovesti do potpunog gubitka vida.
Smatra se da su autoreaktivna antitela na TSH receptore (TSHRAt) prisutna u orbiti i Ŕtitnoj
žlezdi glavni uzroÄnici nastanka GO i GB. Glavni cilj ovog istraživanja bio je ispitivanje
kliniÄkog znaÄaja ovih autoreaktivnih antitela u dijagnostici GO, klasifikaciji pacijenata,
predviÄanju kliniÄkog toka i ishoda ove bolesti. Sa tim u vezi, analizirane su: raspodela ukupne
koncentracije i funkcionalnog profila TSHRAt u razliÄitim grupama pacijenata, njihova
asocijacija sa kliniÄkom slikom bolesti i dijagnostiÄke karakteristike primenjenih analitiÄkih
metoda za njihovo odreÄivanje. Dodatni cilj je bio analiza citokinskog profila i oksidativnog
statusa pacijenata, kao i njihovog meÄusobnog odnosa sa nivoima TSHRAt.
U studiji je uÄestovao 91 pacijent sa postavljenom dijagnozom GO koji nije primao
imunosupresivnu terapiju minimalno Å”est meseci u odnosu na datum ukljuÄenja u studiju.
Pacijenti su leÄeni na Klinici za endokrinologiju, dijabetes i bolesti metabolizma,
Univerzitetskog kliniÄkog centra Srbije, a klasifikovani su u odnosu na vrstu primarne dijagnoze
na: pacijente sa GB, HaŔimoto tiroiditisom (HT) i na pacijente bez tiroidne disfunkcije
(eutiroidna GO, ET GO). Osim toga, klasifikacija pacijenata je izvrÅ”ena i prema kliniÄkim
karakteristikama GO, pre svega prema aktivnosti i težini. Ukupna koncentracija TSHRAt (TSH
vezujuÄi inhibitorni imunoglobulini, TBII) odreÄena je primenom komercijalne rutinske
imunohemijske metode. Stimulatorna (TSHR-stimulatorna antitela, TSAb) i blokirajuÄa
aktivnost antitela (TSHR-blokirajuÄa antitela, TBAb) odreÄene su tehnikom bioeseja. Zasebno su
kvantifikovana stimulatorna i blokirajuÄa antitela. Dodatno je koncentracija TSHRAt izmerena
pomoÄu komercijalne imunohemijske metode koja koristi āsendviÄā princip. Ispitivani citokini i
8-hidroksi-2-deoksigvanozin (8-OhdG) su odreÄeni komercijalnim enzimskim imunohemijskim
testovima, dok su totalni oksidativni stres (TOS) i totalni antioksidantni status (TAS) odreÄeni
spektrofotometrijski, primenom komercijalnih testova...Graves' orbitopathy (GO) is a multifactorial autoimmune disease of insufficiently
investigated etiology and pathogenesis. The basis of this pathology is characterized by an
inflammatory disorder of the orbit. It is mostly occurring in patients with autoimmune thyroid
diseases (AITD), primarily Graves' disease (GD). However, there are known cases of its isolated
occurrence in the absence of thyroid abnormalities. Graves' orbitopathy seriously impairs
patientsā daily activities, vision function and physical appearance, and in severe cases may cause
blindness. Autoreactive antibodies to TSH receptors (TSHRAb) present in the orbit and thyroid
are considered the main causes of both GO and GD. The primary goal of this study was to
examine the clinical significance of these autoantibodies in the diagnosis of GO, patient
classification, prediction of the clinical course and outcome of this disease. In this regard, we
analyzed the distribution of the total TSHRAb concentration and functional profile in different
patient groups, along with their association with the clinical profile of the disease and diagnostic
accuracy of the applied analytical methods for their determination. An additional goal was to
analyze the cytokine profile and oxidative status of patients, as well as their relationship with
TSHRAb levels.
Ninety-one patients diagnosed with GO were enrolled in this study. They had not
received any form of immunosuppressive therapy for at least six months prior the recruitment.
All patients were on a regular follow-up regimen at the Clinic for Endocrinology, Diabetes and
Metabolic Diseases, University Medical Center of Serbia, and were classified according to their
primary diagnosis into: patients with GD, Hashimoto's thyroiditis (HT) and patients without
thyroid dysfunction (euthyroid GO, ET GO). Additionally, patients were classified according to
the clinical characteristics, primarily activity and severity of GO. Total TSHRAb concentration
(TSH binding inhibitory immunoglobulins, TBII) was measured using a commercial routine
immunoassay. Stimulatory and blocking antibody activity (TSHR-stimulating antibodies, TSAb
and TSHR-blocking antibodies, TBAb, respectively) were determined using a bioassay
technique. Stimulatory and blocking antibodies were separately quantified. In addition, TSHRAb
concentration was measured using a commercial "bridge" immunoassay..
Clinical value of thyrotropin receptor antibodies in patients with GravesŹ¹ orbitopathy/ophthalmopathy
Graves-ova orbitopatija (GO) je multifaktorska autoimuna bolest, joÅ” uvek nepotpunoistražene etiologije i patogeneze. Osnovu ove patologije Äini inflamatorni poremeÄaj orbite.ObiÄno se javlja u sklopu autoimunih bolesti tiroidne žlezde (AITB), prvenstveno Graves-ovebolesti (GB), meÄutim poznati su sluÄajevi njene izolovane pojave u odsustvu tiroidnihabnormalnosti. Graves-ova orbitopatija znaÄajno remeti svakodnevne aktivnosti, funkciju vida ifiziÄki izgled pacijenata, a u najtežim sluÄajevima može dovesti do potpunog gubitka vida.Smatra se da su autoreaktivna antitela na TSH receptore (TSHRAt) prisutna u orbiti i Å”titnojžlezdi glavni uzroÄnici nastanka GO i GB. Glavni cilj ovog istraživanja bio je ispitivanjekliniÄkog znaÄaja ovih autoreaktivnih antitela u dijagnostici GO, klasifikaciji pacijenata,predviÄanju kliniÄkog toka i ishoda ove bolesti. Sa tim u vezi, analizirane su: raspodela ukupnekoncentracije i funkcionalnog profila TSHRAt u razliÄitim grupama pacijenata, njihovaasocijacija sa kliniÄkom slikom bolesti i dijagnostiÄke karakteristike primenjenih analitiÄkihmetoda za njihovo odreÄivanje. Dodatni cilj je bio analiza citokinskog profila i oksidativnogstatusa pacijenata, kao i njihovog meÄusobnog odnosa sa nivoima TSHRAt.U studiji je uÄestovao 91 pacijent sa postavljenom dijagnozom GO koji nije primaoimunosupresivnu terapiju minimalno Å”est meseci u odnosu na datum ukljuÄenja u studiju.Pacijenti su leÄeni na Klinici za endokrinologiju, dijabetes i bolesti metabolizma,Univerzitetskog kliniÄkog centra Srbije, a klasifikovani su u odnosu na vrstu primarne dijagnozena: pacijente sa GB, HaÅ”imoto tiroiditisom (HT) i na pacijente bez tiroidne disfunkcije(eutiroidna GO, ET GO). Osim toga, klasifikacija pacijenata je izvrÅ”ena i prema kliniÄkimkarakteristikama GO, pre svega prema aktivnosti i težini. Ukupna koncentracija TSHRAt (TSHvezujuÄi inhibitorni imunoglobulini, TBII) odreÄena je primenom komercijalne rutinskeimunohemijske metode. Stimulatorna (TSHR-stimulatorna antitela, TSAb) i blokirajuÄaaktivnost antitela (TSHR-blokirajuÄa antitela, TBAb) odreÄene su tehnikom bioeseja. Zasebno sukvantifikovana stimulatorna i blokirajuÄa antitela. Dodatno je koncentracija TSHRAt izmerenapomoÄu komercijalne imunohemijske metode koja koristi āsendviÄā princip. Ispitivani citokini i8-hidroksi-2-deoksigvanozin (8-OhdG) su odreÄeni komercijalnim enzimskim imunohemijskimtestovima, dok su totalni oksidativni stres (TOS) i totalni antioksidantni status (TAS) odreÄenispektrofotometrijski, primenom komercijalnih testova...Graves' orbitopathy (GO) is a multifactorial autoimmune disease of insufficientlyinvestigated etiology and pathogenesis. The basis of this pathology is characterized by aninflammatory disorder of the orbit. It is mostly occurring in patients with autoimmune thyroiddiseases (AITD), primarily Graves' disease (GD). However, there are known cases of its isolatedoccurrence in the absence of thyroid abnormalities. Graves' orbitopathy seriously impairspatientsā daily activities, vision function and physical appearance, and in severe cases may causeblindness. Autoreactive antibodies to TSH receptors (TSHRAb) present in the orbit and thyroidare considered the main causes of both GO and GD. The primary goal of this study was toexamine the clinical significance of these autoantibodies in the diagnosis of GO, patientclassification, prediction of the clinical course and outcome of this disease. In this regard, weanalyzed the distribution of the total TSHRAb concentration and functional profile in differentpatient groups, along with their association with the clinical profile of the disease and diagnosticaccuracy of the applied analytical methods for their determination. An additional goal was toanalyze the cytokine profile and oxidative status of patients, as well as their relationship withTSHRAb levels.Ninety-one patients diagnosed with GO were enrolled in this study. They had notreceived any form of immunosuppressive therapy for at least six months prior the recruitment.All patients were on a regular follow-up regimen at the Clinic for Endocrinology, Diabetes andMetabolic Diseases, University Medical Center of Serbia, and were classified according to theirprimary diagnosis into: patients with GD, Hashimoto's thyroiditis (HT) and patients withoutthyroid dysfunction (euthyroid GO, ET GO). Additionally, patients were classified according tothe clinical characteristics, primarily activity and severity of GO. Total TSHRAb concentration(TSH binding inhibitory immunoglobulins, TBII) was measured using a commercial routineimmunoassay. Stimulatory and blocking antibody activity (TSHR-stimulating antibodies, TSAband TSHR-blocking antibodies, TBAb, respectively) were determined using a bioassaytechnique. Stimulatory and blocking antibodies were separately quantified. In addition, TSHRAbconcentration was measured using a commercial "bridge" immunoassay..
DijagnostiÄke karakteristike seroloÅ”kog access SARS-CoV-2 IgG imunohemijskog testa
Uvod i cilj. Pandemija bolesti izazvane teŔkim akutnim respiratornim sindromom korona-
virus 2 (SARS-CoV-2) dovela je do ekspanzije seroloÅ”kih testova za odreÄivanje antitela i an-
tigena virusa. Access SARS-CoV-2 IgG je seroloŔki test namenjen je za detekciju IgG antitela
virusa, i može se koristiti kao dodatno sredstvo prilikom detekcije patogena, praÄenja stanja
pacijenata, procene imuniteta nakon infekcije i vakcinacije. Cilj istraživanja je bio da se odre-
de dijagnostiÄke karakteristike i kliniÄki znaÄaj Access SARS-CoV-2 IgG testa.
Metode. Istraživanjem je obuhvaÄeno 94 ispitanika sa potvrÄenom prethodnom SARS-
CoV-2 infekcijom (PCR metodom) i 104 kontrolna ispitanika. IgG antitela su odreÄena u se-
rumu ispitanika primenom Access Sars-CoV-2 IgG testa, proizvoÄaÄa Beckman Coulter, na
imunohemijskom Access 2 imunoanalizatoru iste firme.
Rezultati. Titar IgG antitela je bio znaÄajno veÄi kod ispitanika koji su preležali infekciju
(3,95 (1,36 - 11,44 S/CO) u odnosu na kontrolne ispitanike (0,03 (0,02 ā 0,16 S/CO) (p <
0,001). ROC analizom je utvrÄena statistiÄki znaÄajna AUC (0,946, p < 0,001), a osetljivost i
specifiÄnost za potvrdu infekcije su redom bile 81% i 95%, za graniÄnu vrednost 0,955. Pozitiv-
na i negativna prediktivna vrednost su bile 94% i 85%, redom. Dodatno je utvrÄeno da je titar
IgG antitela bio najveÄi u grupi ispitanika sa teÅ”kim oblikom infekcije, u poreÄenju sa ispita-
nicima koji su imali lakŔi oblik i ispitanicima koji su imali blagu ili asimptomatsku infekciju (p
= 0,048).
ZakljuÄak. NaÅ”i rezultati ukazuju na to da analizirani Access SARS-CoV-2 IgG seroloÅ”ki
test ima zadovoljavajuÄe dijagnostiÄke karakteristike i može biti kliniÄki znaÄajan za procenu
stanja imuniteta nakon preležane infekcije
AnalitiÄke i kliniÄke karakteristike seroloÅ”kih imonoodreÄivanja anti-SARS-CoV-2 antitela
Uvod i cilj. Literaturni podaci ukazuju da seroloÅ”ka imunoodreÄivanja mogu biti adekvatna
dopuna molekularnoj dijagnostici SARS-CoV-2 infekcije. Cilj ovog ispitivanja je da se proceni
slaganje SARS-CoV-2 seroloÅ”kih testova pet razliÄitih proizvoÄaÄa i ispita imuni odgovor na
razliÄite vrste vakcina.
Metode. KoriÅ”Äene su metode: Sars-CoV-2 IgG (Beckman Coulter) (I), SARS-CoV-2 ukupna
antitela (BioRad) (II), SARS-CoV-2 IgG II Quant (Abbott) (III), SARS-CoV-2 IgG (Abbott) (IV) i
Elecsys Anti-SARS-CoV-2 (Roche) (V). Paralelno je ispitivano metodom I i II 44 uzorka, I i III 84
uzorka, I i IV 53 uzorka, I i V 80 uzoraka. Dodatno je za procenu imunog odgovora na infekciju i
razliÄite vrste vakcina analizirano 153 uzorka. Ispitanici su proveravali prisustvo antitela zbog
sumnje na asimptomatsku SARS-CoV-2 infekciju ili zbog prisustva simptoma.
Rezultati. II i III metodom je dobijen znaÄajno veÄi broj reaktivnih rezultata u odnosu na I
metod (65,9% i 91,7% vs 52,3%). I i IV metode su pokazale slaganje u reaktivnosti (60,4% vs
69,8%), dok I i V metodom nije dobijeno slaganje u reaktivnosti rezultata (58,8% vs 93,8%).
Najintenzivniji imuni odgovor postignut je nakon vakcinacije Phizer vakcinom. Imuni odgovor
nakon Phizer i Sinopharm vakcine je pokazao znaÄajnu korelaciju sa vremenom proteklim od
imunizacije (P=0,032 i P=0,012). Žene su imale znaÄajno viÅ”i titar antitela nakon vakcinacije
u odnosu na muÅ”karce (P=0,006). Nije dobijena znaÄajna razlika u odnosu na tip vakcine i
godina starosti ispitanika (P=0,197).
ZakljuÄak
Iako seroloÅ”ka imunoodreÄivanja pokazuju znaÄajne analitiÄke i kliniÄke karakteristike za
detekciju SARS-CoV-2 i dalje postoji problem kompletne evaluacije testova i neizvesnosti u
pogledu taÄnosti rezultata i njihove uporedivosti
Osetljivost tri testa za odreÄivanje antitela na receptor za tireostimuliÅ”uÄi hormon kod pacijenata sa orbitopatijom udruženom sa Å”titnom žlezdom
Background: Thyrotropin receptor autoantibodies (TSH-R-Ab) are indispensable biomarkers in the laboratory assessment of thyroid-associated orbitopathy (TAO). Clinical sensitivity of three different assays for TSH-R-Ab determination was evaluated in patients with TAO.
Methods: 87 consecutive TAO patients were enrolled and their serum samples analyzed in parallel with three assays. An ECLIA competitive binding and a chemiluminescent bridge immunoassay were used to measure total and bind-ing TSH-R-Ab concentration, while their functional activity was determined using a stimulatory TSH-R-Ab (TSAb) cell-based bioassay.
Results: Compared to the two binding assays (ECLIA p<0.001, bridge p=0.003), the TSAb bioassay was more sensitive pertaining to the positive detection of TSH-R-Ab in TAO patients. No difference (p=0.057) was noted between the ECLIA and bridge assays regarding sensitivity rate. All patients with active and/or moderate-to-severe TAO tested positive in the TSAb bioassay (100% and 100%, respectively), while the positivity rates for bridge and ECLIA binding assays were 89.7% and 82.1% for active TAO, and 90.2% and 86.3% for severe TAO, respectively. Negative predictive values of the bioassay, bridge, and ECLIA assays were 100%, 75%, and 71%, respectively for active TAO, and 100%, 86%, and 71%, respectively for moderate-to-severe TAO. The superiority of the bioassay was most prominent in euthyroid (ET) TAO. Positivity rates of the TSAb bioassay, bridge and ECLIA binding assays were 89.6%, 75%, and 64.6%, respectively for inactive TAO; 86.1%, 69.4%, and 52.8%, respectively for mild TAO; 87.5%, 62.5%, and 12.5%, respectively for euthyroid TAO. The bridge assay correlated better with the ECLIA binding assay (r=0.893, p<0.001), compared to the bioassay (r=0.669, p<0.001).
Conclusions: In patients with TAO of various activity and severity, the TSAb bioassay demonstrates a superior clinical performance compared to both ECLIA and bridge binding assays.Uvod: Autoantitela na receptore za tireostimuliÅ”uÄi hormon (TSH-R-Ab) su nezamenljivi biomarkeri u laboratorijskoj proceni orbitopatije udru'ene sa Å”titnom žlezdom (TAO). U radu je procenjena kliniÄka osetljivost tri razliÄita testa za odreÄivanje TSH-R-Ab kod pacijenata sa TAO. Metode: U studiju je kljuÄeno 87 uzastopnih pacijenata sa TAO i njihovi uzorci seruma su analizirani paralelno sa tri testa. Za merenje ukupne i vezujuÄe koncentracije TSH-RAb koriÅ”Äeni su ECLIA imunohemijski test kompetitivnog vezivanja i hemiluminiscentni imunohemijski "sendviÄ" test, dok je njihova funkcionalna aktivnost odreÄena pomoÄu Äelijskog bioloÅ”kog testa (bioeseja) za odreÄivanje stimulatornih TSH-R-Ab (TSAb). Rezultati: U poreÄenju sa dva imunohemijska testa vezivanja (ECLIA P<0,001, "sendviÄ test" P=0,003), TSAb bioesej se pokazao najosetljivijim u pogledu pozitivne detekcije TSH-RAb kod TAO pacijenata. Nikakva razlika nije detektovana (P=0,057) izmeÄu ECLIA i "sendviÄ" testa u pogledu stope osetljivosti. TSAb bioesej je bio pozitivan kod svih pacijenata sa aktivnom i/ili umerenom do teÅ”kom TAO (redom 100% i 100%), dok su stope pozitivnosti za sendviÄ i ECLIA imunohemijski test bile 89,7% i 82,1% za aktivnu TAO, i 90,2% i 86,3% za teÅ”ku TAO, redom. Negativne prediktivne vrednosti bioeseja, "sendviÄ" i ECLIA testova bile su redom 100%, 75% i 71%, za aktivnu TAO, odnosno 100%, 86% i 71%, redom za umerenu do teÅ”ku TAO. Superiornost bioloÅ”ke analize bila je najistaknutija kod eutiroidnog oblika (ET) TAO. Stope pozitivnosti TSAb bioeseja, "sendviÄ" i ECLIA testova vezivanja bile su redom 89,6%, 75% i 64,6%, za neaktivnu TAO; 86,1%, 69,4% i 52,8% za blagu TAO; 87,5%, 62,5% i 12,5% za eutiroidni TAO. "SendviÄ" imunohemijski test je bio u boljoj korelaciji sa ECLIA testom kompetitivnog vezivanja (r=0,893, P<0,001), u poreÄenju sa bioesejom (r=0,669, P<0,001). ZakljuÄak: Kod pacijenata sa TAO razliÄite aktivnosti i težine TSAb bioesej pokazuje superiorne kliniÄke performanse u poreÄenju sa obe vrste imunohemijskih testova vezivanja (ECLIA i "sendviÄ test")
The Effects of Pregestational Overweight and Obesity on Maternal Lipidome in Pregnancy: Implications for Newbornsā Characteristics
Obesity is an important risk factor for the development of pregnancy complications. We investigated the effects of pregestational overweight and obesity on maternal lipidome during pregnancy and on newbornsā characteristics. The study encompassed 131 pregnant women, 99 with pre-pregnancy body mass index (BMI) < 25 kg/m2 and 32 with BMI ā„ 25 kg/m2. Maternal lipid status parameters, plasma markers of cholesterol synthesis and absorption and sphingolipids were determined in each trimester. Data on neonatal height, weight and APGAR scores were assessed. The results showed a higher prevalence (p < 0.05) of pregnancy and childbirth complications among the participants with elevated pregestational BMI. Levels of total cholesterol, HDL-cholesterol (p < 0.05) and LDL-cholesterol (p < 0.01) were significantly lower, and concentrations of triglycerides were higher (p < 0.05) in women with increased pre-gestational BMI. Lower concentrations of the cholesterol synthesis marker, desmosterol, in the 2nd trimester (p < 0.01) and the cholesterol absorption marker, campesterol, in each trimester (p < 0.01, p < 0.05, p < 0.01, respectively) were also found in this group. Markers of maternal cholesterol synthesis were in positive correlation with neonatal APGAR scores in the group of mothers with healthy pre-pregnancy weight but in negative correlation in the overweight/obese group. Our results indicate that gestational adaptations of maternal lipidome depend on her pregestational nutritional status and that such changes may affect neonatal outcomes
Clinical value of thyrotropin receptor antibodies in patients with GravesŹ¹ orbitopathy/ophthalmopathy
Graves-ova orbitopatija (GO) je multifaktorska autoimuna bolest, joÅ” uvek nepotpuno
istražene etiologije i patogeneze. Osnovu ove patologije Äini inflamatorni poremeÄaj orbite.
ObiÄno se javlja u sklopu autoimunih bolesti tiroidne žlezde (AITB), prvenstveno Graves-ove
bolesti (GB), meÄutim poznati su sluÄajevi njene izolovane pojave u odsustvu tiroidnih
abnormalnosti. Graves-ova orbitopatija znaÄajno remeti svakodnevne aktivnosti, funkciju vida i
fiziÄki izgled pacijenata, a u najtežim sluÄajevima može dovesti do potpunog gubitka vida.
Smatra se da su autoreaktivna antitela na TSH receptore (TSHRAt) prisutna u orbiti i Ŕtitnoj
žlezdi glavni uzroÄnici nastanka GO i GB. Glavni cilj ovog istraživanja bio je ispitivanje
kliniÄkog znaÄaja ovih autoreaktivnih antitela u dijagnostici GO, klasifikaciji pacijenata,
predviÄanju kliniÄkog toka i ishoda ove bolesti. Sa tim u vezi, analizirane su: raspodela ukupne
koncentracije i funkcionalnog profila TSHRAt u razliÄitim grupama pacijenata, njihova
asocijacija sa kliniÄkom slikom bolesti i dijagnostiÄke karakteristike primenjenih analitiÄkih
metoda za njihovo odreÄivanje. Dodatni cilj je bio analiza citokinskog profila i oksidativnog
statusa pacijenata, kao i njihovog meÄusobnog odnosa sa nivoima TSHRAt.
U studiji je uÄestovao 91 pacijent sa postavljenom dijagnozom GO koji nije primao
imunosupresivnu terapiju minimalno Å”est meseci u odnosu na datum ukljuÄenja u studiju.
Pacijenti su leÄeni na Klinici za endokrinologiju, dijabetes i bolesti metabolizma,
Univerzitetskog kliniÄkog centra Srbije, a klasifikovani su u odnosu na vrstu primarne dijagnoze
na: pacijente sa GB, HaŔimoto tiroiditisom (HT) i na pacijente bez tiroidne disfunkcije
(eutiroidna GO, ET GO). Osim toga, klasifikacija pacijenata je izvrÅ”ena i prema kliniÄkim
karakteristikama GO, pre svega prema aktivnosti i težini. Ukupna koncentracija TSHRAt (TSH
vezujuÄi inhibitorni imunoglobulini, TBII) odreÄena je primenom komercijalne rutinske
imunohemijske metode. Stimulatorna (TSHR-stimulatorna antitela, TSAb) i blokirajuÄa
aktivnost antitela (TSHR-blokirajuÄa antitela, TBAb) odreÄene su tehnikom bioeseja. Zasebno su
kvantifikovana stimulatorna i blokirajuÄa antitela. Dodatno je koncentracija TSHRAt izmerena
pomoÄu komercijalne imunohemijske metode koja koristi āsendviÄā princip. Ispitivani citokini i
8-hidroksi-2-deoksigvanozin (8-OhdG) su odreÄeni komercijalnim enzimskim imunohemijskim
testovima, dok su totalni oksidativni stres (TOS) i totalni antioksidantni status (TAS) odreÄeni
spektrofotometrijski, primenom komercijalnih testova...Graves' orbitopathy (GO) is a multifactorial autoimmune disease of insufficiently
investigated etiology and pathogenesis. The basis of this pathology is characterized by an
inflammatory disorder of the orbit. It is mostly occurring in patients with autoimmune thyroid
diseases (AITD), primarily Graves' disease (GD). However, there are known cases of its isolated
occurrence in the absence of thyroid abnormalities. Graves' orbitopathy seriously impairs
patientsā daily activities, vision function and physical appearance, and in severe cases may cause
blindness. Autoreactive antibodies to TSH receptors (TSHRAb) present in the orbit and thyroid
are considered the main causes of both GO and GD. The primary goal of this study was to
examine the clinical significance of these autoantibodies in the diagnosis of GO, patient
classification, prediction of the clinical course and outcome of this disease. In this regard, we
analyzed the distribution of the total TSHRAb concentration and functional profile in different
patient groups, along with their association with the clinical profile of the disease and diagnostic
accuracy of the applied analytical methods for their determination. An additional goal was to
analyze the cytokine profile and oxidative status of patients, as well as their relationship with
TSHRAb levels.
Ninety-one patients diagnosed with GO were enrolled in this study. They had not
received any form of immunosuppressive therapy for at least six months prior the recruitment.
All patients were on a regular follow-up regimen at the Clinic for Endocrinology, Diabetes and
Metabolic Diseases, University Medical Center of Serbia, and were classified according to their
primary diagnosis into: patients with GD, Hashimoto's thyroiditis (HT) and patients without
thyroid dysfunction (euthyroid GO, ET GO). Additionally, patients were classified according to
the clinical characteristics, primarily activity and severity of GO. Total TSHRAb concentration
(TSH binding inhibitory immunoglobulins, TBII) was measured using a commercial routine
immunoassay. Stimulatory and blocking antibody activity (TSHR-stimulating antibodies, TSAb
and TSHR-blocking antibodies, TBAb, respectively) were determined using a bioassay
technique. Stimulatory and blocking antibodies were separately quantified. In addition, TSHRAb
concentration was measured using a commercial "bridge" immunoassay..
UsklaÄenost POCT metode sa potpuno automatizovanom metodom za odreÄivanje HbA1c
Previous research suggests that point-of-care (POCT) determination of glycated hemoglobin (HbA1c) is a diagnostic test that can be an adequate alternative to measuring HbA1c in the laboratory. The main goal of this study was to examine the analytical characteristics of the novel INCLIX POCT method for HbA1c determination in order to test its performance before introducing this method into routine use. HbA1c is measured in a duplicate in 44 EDTA blood samples parallel on INCLIX POCT device (Sugitech, Inc.) and using automated turbidimetric immunoinhibition test on Olympus AU400 (Beckman Coulter). The within run imprecision was 7.58%, between runs imprecision was 6.63% and 6.22%, and day-to-day imprecision was 8.80% and 7.51%. Total laboratory imprecision was in agreement with those stated by the manufacturer. A statistically significant Pearson correlation coefficient was calculated (r = 0.871, P < 0.01; linear R2 = 0.757). Using Deming regression analysis, the following equation was obtained: y = - 1.80 + 1.304x. Our results indicate statistically significant correlation, linear relationship, and a significant degree of compatibility between the two analyzed methods. However, the negative bias of the HbA1c values determined on the POCT analyzer compared to the Olympus AU400 was confirmed, highlighting the need to standardize the INCLIX method.Prethodna istraživanja sugeriÅ”u da je āpoint-of-careā metoda (POCT) za odreÄivanje glikoziliranog hemoglobina (HbA1c) dijagnostiÄki test koji može biti adekvatna alternativa merenju HbA1c u laboratoriji. Glavni cilj ovog istraživanja bio je da se ispitaju analitiÄke karakteristike nove INCLIX POCT metode za odreÄivanje HbA1c kako bi se testirale karakteristike izvoÄenja pre uvoÄenja ove metode u rutinsku upotrebu. HbA1c je meren u duplikatu u 44 uzorka EDTA krvi paralelno na INCLIX POCT ureÄaju (Sugitech, Inc.) i automatskim turbidimetrijskim imunoinhibicijskim testom na Olympus AU400 biohemijskom analizatoru (Beckman Coulter). Nepreciznost u seriji bila je 7,58%, nepreciznost izmeÄu serija bila je 6,63% i 6,22%, a nepreciznost iz dana u dan bila je 8,80% i 7,51%. Ukupna laboratorijska nepreciznost bila je u slaganju sa podacima koje je naveo proizvoÄaÄ. IzraÄunat je statistiÄki znaÄajan Pearsonov koeficijent korelacije (r = 0,871, P < 0,01; linearni R2 = 0,757). Demingovom regresionom analizom dobijena je sledeÄa jednaÄina: y = -1,80 + 1,304x. NaÅ”i rezultati ukazuju na statistiÄki znaÄajnu korelaciju, linearnu povezanost i znaÄajan stepen kompatibilnosti izmeÄu dve analizirane metode. MeÄutim, potvrÄen je negativan bias vrednosti HbA1c odreÄenih na POCT analizatoru u odnosu na Olympus AU400, Å”to istiÄe potrebu za standardizacijom INCLIX metode
PoreÄenje imunohemijske metode i elektroforetske tehnike za odreÄivanje koÅ”tanog izoenzima alkalne fosfataze kod pacijenata na hemodijalizi
Background: Problem of the variability between the different methods using for bone alkaline phosphatase(bALP) determination greately influences the clinical significance of bALP as direct marker of bone metabolism.The aim of this study was to compare immunoassay with electrophoresis technique for bALP determination. Methods: We measured bALP in 71 patients on hemodialysis with agar gel electrophoresis (ISO-PAL, SEBIA) and immunoassay (OSTASE, Beckman Coulter).Results: The analyzed methods showed significant correlation (Spearmanās rho: 0.776, P < 0.01), but we found statistically significant (P < 0.01) positive bias (27%)for the results measured by immunoassay. In support of this, using electrophoresis technique we have detected presence of the intestinal isoenzymes of alkaline phosphatase in 55% of patients with median value of 30% of the total alkaline phoshatase and presence of liver-2 alkaline phosphatase isoform in 42% of patients with median value of 16.6%. The Kendallās W of 0.787 (P<0.0001) revealed significant concordance between two analysed methods.Cusum test showed no significant deviation from linearity(P=0.850).Conclusions:Despite good agreement between immunoassay methods and electrophoresis technique for bALP determination, interchangeability between these two methods is questionable. Although immunoassays are increasingly used, as fully automated methods, in a large number of laboratories and become routine methods for bALP determination, it should be beared in mind, besidesvarious interferences, also the heterogeneity of the bALP itself, especially in patients on hemodialysis.Uvod: Problem varijabilnosti izmeÄu razliÄitih metoda pomoÄu kojih se odreÄuje koÅ”tani izoezim alkalne fosfataze (bALP) u velikoj meri utiÄe na kliniÄki znaÄaj bALP kao direktnog markera metabolizma kostiju. Cilj ove studije bio je poreÄenje imunohemijskog testa sa elektroforetskom tehnikom za odreÄivanje bALP. Metode: bALP je odreÄen kod 71 pacijenta na hemodijalizi, agar gel elektroforetskom tehnikom (ISO-PAL, SEBIA) i imunohemijskom metodom (OSTASE, Beckman Coulter). Rezultati: Analizirane metode pokazale su znaÄajno slaganje (Spearmanov rho: 0,776, P < 0,01), ali je uoÄen statistiÄki znaÄajan (P < 0,01) pozitivan bias (27%) za rezultate izmerene imunohemijskom metodom. U prilog ovome, primenom elektroforetske tehnike, otkrili smo prisustvo intestinalnih izoenzima alkalne fosfataze u 55% bolesnika, sa srednjom vrednosti od 30% ukupne alkalne fostataze, kao i prisustvo jetrenih izoformi alkalne fosfataze kod 42% bolesnika sa srednjom vrednosti od 16,6%. Kendall-ov W od 0,787 (P < 0,0001) ukazivao je na znaÄajno slaganje izmeÄu dve analizirane metode. Cusumov test nije pokazao znaÄajno odstupanje od linearnosti (P = 0,850). ZakljuÄak: Uprkos tome Å”to postoji dobro slaganje izmeÄu imunohemijske metode i elektroforetske tehnike za odreÄivanje bALP-a, meÄusobna zamenjivost ove dve metode je pod znakom pitanja. Iako se imunohemijske metode sve viÅ”e koriste kao potpuno automatizovane, u velikom broju laboratorija i postaju rutinske metode za odreÄivanje bALP-a, treba imati na umu, osim razliÄitih interferencija, i heterogenost samog bALP, posebno kod bolesnika na hemodijalizi
Je li aluminijev oksid pogodan za postupak ekstrakcije Ävrste faze katekolamina iz moždanoga tkiva?
Occupational and environmental toxicology specialists find catecholamine fluctuations in brain tissue relevant for research of neurotoxicity, such as that induced by manganese or zinc, pesticides, industrial solvents, plastic, air pollution, or irradiation. Considering that catecholamine tissue concentrations are generally very low, their extraction requires a reliable and optimal method that will achieve maximum recovery and minimise other interferences. This study aimed to evaluate whether the aluminium (III) oxide (Al2O3, alumina) based cartridges designed for catecholamine isolation from plasma could be used for solid-phase extraction (SPE) of catecholamine from the brain tissue. To do that, we homogenised Wistar rat brain tissue with perchloric acid and compared three extraction techniques: SPE, the routine filtration through a 0.22 Āµm membrane filter, and their combination. In the extracts, we compared relative chromatographic catecholamine mobility measured with high performance liquid chromatography with electrochemical detection. Chromatographic patterns for norepinephrine and epinephrine were similar regardless of the extraction technique, which indicates that the alumina cartridge is good enough to isolate them from brain tissue. However, the dopamine pattern was unsatisfactory, and further experiments are needed to identify the issue and optimise the protocol. Ā© 2023 DuÅ”ko MirkoviÄ et al., published by Sciendo. Promjene razine katekolamina (KAT) u moždanom tkivu znaÄajne su za brojna podruÄja profesionalne toksikologije odnosno ekotoksikologije u kojima se istražuje neurotoksiÄnost izazvana razliÄitim agensima poput mangana ili cinka, pesticida, industrijskih otapala, plastike, aerozagaÄenja ili zraÄenja. Niske koncentracije KAT-a u tkivu zahtijevaju pouzdanu i uÄinkovitu tehniku ekstrakcije kojom se postiže maksimalni āprinosā katekolamina i minimalni sadržaj interferirajuÄih spojeva. Cilj istraživanja bio je procijeniti mogu li se kolone na bazi aluminijeva (III) oksida (Al2O3), dizajnirane za izolaciju KAT-a iz plazme, koristiti za ekstrakciju Ävrstom fazom (eng. solid-phase extraction ā SPE) KAT-a iz moždanoga tkiva. Nakon homogenizacije tkiva Sprague Dawley Å”takora upotrebom perklorne kiseline, primijenjene su tri tehnike ekstrakcije: SPE, filtracija kroz 0,22 Āµm membranski filtar, koji je zapravo rutinska tehnika za izolaciju KAT-a iz mozga, i kombinacija tih dviju tehnika. U ekstraktima je relativna kromatografska pokretljivost KAT-a analizirana HPLC metodom s elektrokemijskom detekcijom. PonaÅ”anje norepinefrina i epinefrina tijekom kromatografije bilo je sliÄno, bez obzira na tehniku ekstrakcije, Å”to upuÄuje na to da aluminijev oksid ima zadovoljavajuÄa svojstva izolirati ta dva KAT-a iz moždanoga tkiva. MeÄutim, uoÄeni su problemi s ekstrakcijom dopamina, koji zahtijevaju dodatne eksperimente kako bi se otkrio njihov uzrok i osmislio protokol optimizacije. Author keywords aluminijev oksid; aluminium oxide; brain; catecholamines; ekstrakcija Ävrste faze; katekolamini; mozak; solid phase extraction; tissue; tkivo Ā© This record is sourced from MEDLINE/PubMed, a database of the U.S. National Library of Medicine 1of1 Top of page Cited by 0 documents Inform me when this document is cited in Scopus: Related documents Find more related documents in Scopus based on: Authors KeywordsPromjene razine katekolamina (KAT) u moždanom tkivu znaÄajne su za brojna podruÄja profesionalne toksikologije odnosno ekotoksikologije u kojima se istražuje neurotoksiÄnost izazvana razliÄitim agensima poput mangana ili cinka, pesticida, industrijskih otapala, plastike, aerozagaÄenja ili zraÄenja. Niske koncentracije KAT-a u tkivu zahtijevaju pouzdanu i uÄinkovitu tehniku ekstrakcije kojom se postiže maksimalni āprinosā katekolamina i minimalni sadržaj interferirajuÄih spojeva. Cilj istraživanja bio je procijeniti mogu li se kolone na bazi aluminijeva (III) oksida (Al2 O 3), dizajnirane za izolaciju KAT-a iz plazme, koristiti za ekstrakciju Ävrstom fazom (eng. solid-phase extraction ā SPE) KAT-a iz moždanoga tkiva. Nakon homogenizacije tkiva Sprague Dawley Å”takora upotrebom perklorne kiseline, primijenjene su tri tehnike ekstrakcije: SPE, filtracija kroz 0,22 Ī¼m membranski filtar, koji je zapravo rutinska tehnika za izolaciju KAT-a iz mozga, i kombinacija tih dviju tehnika. U ekstraktima je relativna kromatografska pokretljivost KAT-a analizirana HPLC metodom s elektrokemijskom detekcijom. PonaÅ”anje norepinefrina i epinefrina tijekom kromatografije bilo je sliÄno, bez obzira na tehniku ekstrakcije, Å”to upuÄuje na to da aluminijev oksid ima zadovoljavajuÄa svojstva izolirati ta dva KAT-a iz moždanoga tkiva. MeÄutim, uoÄeni su problemi s ekstrakcijom dopamina, koji zahtijevaju dodatne eksperimente kako bi se otkrio njihov uzrok i osmislio protokol optimizacije