33 research outputs found
DESENVOLVIMENTO E AVALIAÇÃO DE ANEMÔMETRO DE COPOS DE FÁCIL CONSTRUÇÃO E OPERAÇÃO
The objective of this study was to construct and evaluate a cups anemometer (prototype) with digital readings of instantaneous, average and maximum wind speeds, using cheap and easy building materials. The prototype sensor is compound of three ladles fixed to a rotor mounted on a spindle free. The gauge consists of a permanent magnet, where a spindle rotates the pole. This produces a variable magnetic field, which indicates directly the wind speed in a crystal liquid display. The prototype calibration was performed in the laboratory, at a wind tunnel, comparing its speed with values measured by a highly accurate standard anemometer. The results showed that the prototype presented a starting speed of 0.70 m.s-1 and the digital measure presented sensibility for speedreadings above 0.85 m.s-1. There were no differences (P<0.05) between the wind speeds measured with the prototype and the standard anemometer.Este trabalho teve como objetivos construir e avaliar um anemômetro de copos (protótipo) com leitura digital da velocidade instantânea, média e máxima do vento, utilizando materiais de baixo custo e de fácil construção. O sensor do protótipo é do tipo copos rotativos (3) presos em hastes que são unidas a um eixo central comum. O sistema medidor consiste de um magneto permanente, girando com o eixo central, produzindo um campo magnético variável, que indica diretamente a velocidade do vento no display de cristal líquido. A avaliação do protótipo foi realizada em um túnel de vento comparando a velocidade do protótipo com a de um anemômetro de alta precisão, denominado padrão. Os resultados mostraram que o protótipo apresentou velocidade de partida de 0,70 m.s-1 e o medidor digital apresentou sensibilidade para leituras de velocidades acima de 0,85 m.s-1. As velocidades observadas pelo protótipo não apresentaram diferenças (P<0,05) em relação às velocidades do anemômetro padrão
Amônia, gás sulfídrico, metano e monóxido de carbono na produção de suínos
Information about gases concentrations and their effects on animal and human’s welfare in swine confinement production systems are scarce in Brazil. The objectives of this research were to evaluate the air quality (NH3, H2S, CH4 and CO) and to estimate the worker occupational risk exposition at growing and finishing commercial swine production facilities. The results showed that average concentrations of H2S, CO and CH4 were lower than 1 ppm, smaller than 1 ppm, and lower than 0.1% by volume, respectively. Such concentration levels are not dangerous to animals and workers health according to the recommended norms. The average concentration of NH3 was significantly affected (P < 0.05) by the feeding schedule, installation type and evaluated period.Informações sobre gases e seus efeitos no bem-estar do animal e do trabalhador em sistemas de produção de suínos para as condições brasileiras são escassas. Este trabalho possui os seguintes objetivos: avaliar amônia (NH3), sulfeto de hidrogênio (H2S), metano (CH4) e monóxido de carbono (CO) e estimar os riscos de exposição ocupacional na produção de suínos nas fases de creche e terminação. Os resultados mostraram que as concentrações médias de H2S e CO ficaram abaixo de 1 ppm e de CH4 foram inferiores a 0,1% em volume no ar, não ultrapassando os limites recomendados pelas normas para os animais e ao trabalhador. Foram observadas diferenças (P < 0,05) nas concentrações médias de NH3 em relação aos horários, às instalações e aos períodos avaliados
Construção e calibração de anemômetros de baixo custo
This work was carried out aiming to build and calibrate low cost anemometers to measure the wind speed in the Agrometeorological CAV station. Two Robinsom anemometers with three and four shells and one small anemometer with four shells were built. The construction procedure followed technical approaches regarding to the dimension and operation relationship, employing materials of low cost and the use of manufacture work. The project was performed in the Meteorology and Mechanization section of CAV/ UDESC, in the city of Lages, southern Brazil. A wind tunnel was built according to technical norms of National Association of Fan Manufactures to calibrate the meters. A factory Robinsom anemometer type was also tested. The following relations with the average velocity to the standard meter were obtained: Vp = 1.01 Vm + 2.09 (R2 = 0.96), Vp = 1.09 Vm + 5.32 (R2 = 0.84), Vp = 0.98 Vm + 1.36 (R2=0.92) and Vp = 1.17 Vm + 1.81 (R2=0.95), where Vp is the average speed of the standard meter (km h-1) and Vm is the average speed of the tested anemometer (km h-1), corresponding to the anemometer of four shells, three shells, the small anemometer of four shells and the factory anemometer, respectively.O objetivo deste trabalho foi construir e calibrar anemômetros de baixo custo para a caracterização do vento na Estação Agrometeorológica do Centro de Ciências Agroveterinárias (CAV). Foram construídos dois anemômetros do tipo Robinsom com três e quatro conchas e um micro-anemômetro de quatro conchas. A construção seguiu os critérios técnicos quanto às dimensões e funcionamento, porém com o emprego de materiais de baixo custo e uso de mão de obra artesanal que contemplou os serviços de moldagem e ajustes gerais. O projeto foi desenvolvido nos setores de Meteorologia e Mecanização do CAV/UDESC, em Lages, Santa Catarina. Para a calibração dos medidores foi construído um túnel de vento, segundo normas técnicas da National Association of Fan Manufatures. Foram testados os anemômetros anteriormente citados, bem como um anemômetro de fábrica tipo Robinsom, obtendo-se as seguintes relações com a velocidade média do medidor padrão: Vp = 1,01 Vm + 2,09 (R2 = 0,96), Vp = 1,09 Vm + 5,32 (R2 = 0,84), Vp = 0,98 Vm + 1,36 (R2 = 0,92) e Vp = 1,17 Vm + 1,81 (R2=0,95), onde Vp é a velocidade média do medidor padrão (km h-1) e Vm a velocidade média do anemômetro testado (km h-1), correspondendo ao anemômetro de quatro conchas, de três conchas, micro-anemômetro e anemômetro de fábrica, respectivamente
Água de chuva de telhados: perspectivas da qualidade de água e potencial uso em áreas rurais
Rainwater can be harvested from different roofs of rural buildings, which can be stored for multipurpose depending on its quality. This technical note describes rainwater quality collected directly from the atmosphere and after passing through four types of roofs that are: French ceramic (roof1/Agronomy school building), fiber cement (roof2/farm machinery shed), or French ceramic (roof3/sheep housing), and French ceramic (roof4- swine housing) located inside Agroveterinary School Campus (CAV/UDESC) in Lages, Santa Catarina state, Brazil. The parameters analyzed were pH, color, turbidity, dissolved oxygen, total coliforms, and thermotolerant coliforms. Results showed that pH “in natura” rainwater was variable and below 7.0 with an average of 6.02. However, after passing through the roof, there was an increase in the pH (average) to 6.34 (roof1), 6.90 (roof2), 7.14 (roof3) and 6.50 (roof4). The rainwater also presented variations in the parameters of turbidity, dissolved oxygen, and coliforms after passing through roofs. Thus, the rainwater can potentially be used for non-potable purposes, being then advised of their use without treatment for cleaning of nearby environments of these rural buildings, as well as the irrigation of trees and ornamental plants, among others.Água da chuva pode ser captada de diferentes telhados de construções rurais e esta pode ser armazenada para múltiplos propósitos dependendo de sua qualidade. Esta nota técnica relata a avaliação da água da chuva coletada diretamente da atmosfera e após passar por quatro tipos de telhados que são: de cerâmica francesa (telhado1/prédio da escola de Agronomia), de fibrocimento (telhado2/galpão de máquinas agrícolas), de cerâmica francesa (telhado3/instalação para ovinos) e de cerâmica francesa (telhado4/instalação para suínos), localizados no Centro de Ciências Agroveterinárias, Lages/SC. Os parâmetros analisados foram pH, cor, turbidez, oxigênio dissolvido, coliformes totais e termotolerantes. Os resultados mostraram que o pH da água da chuva “in natura” foi variável e abaixo de 7,0 com pH (médio) de 6,02, que após passar pelos telhados houve aumento do pH (médio) para 6,34 (telhado1), 6,90 (telhado2), 7,14 (telhado3) e 6,50 (telhado4) e com variações também nos parâmetros turbidez, oxigênio dissolvido e de coliformes. Desta forma, a água de chuva apresenta potencial em ser utilizada para fins não potáveis, sendo então aconselhado seu uso sem tratamento para limpeza dos ambientes próximos destas construções rurais, bem como a irrigação de árvores e plantas ornamentais, entre outros
DESENVOLVIMENTO DE UM COLETOR SOLAR UTILIZANDO RECICLAGEM DE LÂMPADAS FLUORESCENTES
The adoption of solar collector to water heating is limited in Brazil. The objective of this research was to develop an alternative solar collector to water heating using recycled fluorescent lamps. The collector was evaluated measuring the daily evolution of water temperature from 8:00 a.m. to 6:00 p.m. The measurements were performed from February 12 to 16, July 12 to 15 and December 12 to 15 of 2001. The statistics studies consisted of regression analysis. The results showed that the solar collector presented high thermal yield, especially in days with low solar radiation. The water maximum temperature inside the collector occurred around 4:00 p.m. The maximum absolute temperature values were 51.5oC, 41.0oC and 55.0oC in February, July and December, respectively.O uso de coletores solares para aquecimento de água ainda é pouco difundido no Brasil. O objetivo deste trabalho foi desenvolver um coletor solar plano para aquecimento de água utilizando lâmpadas fluorescentes queimadas. O coletor foi avaliado medindo-se a evolução da temperatura diária da água e calculando o seu rendimento térmico em três períodos distintos (12 a 16 de fevereiro, 12 a 15 de julho e 12 a 15 de dezembro de 2001). As medidas da radiação solar foram realizadas com actinógrafo bimetálico e das temperaturas de interesse realizadas com termômetro de mercúrio. O estudo estatístico consistiu em análise de regressão. Os resultados mostraram que o coletor solar apresentou maior rendimento térmico em dias de menor radiação solar e que a temperatura máxima da água ocorreu por volta das 16 horas, atingindo um máximo absoluto de 51,5oC, 41,0oC e 55,0oC nos meses de fevereiro, julho e dezembro, respectivamente
Representativeness of the field of rural buildings and ambience in Brazilian journals / Representatividade do campo dos edifícios rurais e do ambiente nas revistas brasileiras
According to CAPES, Rural Buildings and Ambience is an area of concentration within the knowledge subarea of Agriculture Engineering which is part of the field of Agrarian Sciences. In the last 20 years, the Brazilian journals on Agrarian Sciences that publish articles related to Rural Buildings and Ambience have significantly increased the number of published documents, especially after the year 2006. Nevertheless, the number of articles in this area of concentration is not expressive when compared to the total of articles published in other areas of Agrarian Sciences. Considering the current scenario of the national agricultural production, especially for animal production, all parameters involving rural buildings, as well as climate and air quality analysis indoors, play a very relevant role in production efficiency, raising the importance of research in this area. Therefore, they would increase the number of published scientific articles. This work started with a systematic quantitative analysis of the last 21 years of scientific publications, considering 16 Brazilian journals and selecting 824 articles, revealing low representativeness of the area of concentration Rural Buildings and Ambience within the field of Agrarian Sciences, although important information was collected and tabulated for the growth of this sector in the national industry
Comparação do custo de produção de painel CLT produzido artesanalmente com outros materiais de construção convencionais / Comparison of the production cost of CLT panel produced by hand with other conventional construction materials
A crescente utilização da madeira na construção civil coincide com o desenvolvimento de novos produtos que possibilitam uma construção mais rápida, econômica e com maior qualidade. Destaca-se entre esses produtos o painel CLT – Cross Laminated Timber. Este produto foi desenvolvido na Europa nas últimas décadas. O trabalho tem como objetivo realizar uma análise de custos de produção do painel CLT com os materiais convencionais utilizados na construção. Foi confeccionado um painel estrutural em tamanho real com 3 camadas com madeira reflorestada de Pinus taeda. Durante a produção a quantidade de produtos e tempo gastos para a fabricação de forma artesanal foram mensurados. A comparação de custos foi realizada em relação a alvenaria estrutural e a alvenaria de vedação. Notou-se que o painel CLT apresenta um custo de 37% menor que a alvenaria de vedação e de 18,5% menor que a alvenaria estrutural, indicando um grande potencial para a sua produção na região de Lages- SC.
Classificação visual e mecânica da espécie Cryptomeria japonica D. Don para utilização em madeira laminada colada
The objective was to evaluate the mechanical properties, the visual classification influence of Cryptomeria japonica D. Don at the mechanical performance to use it as glulam structural elements, comparing with the minimum requirements demanded by the Brazilian Standard ABNT NBR 7190 (1997) and European Standard EN 338 (2006). The tests for the characterization of the physical and mechanical properties of solid timber followed the recommendations of COPANT 461 (1972), 464 (1972), 555 (973) for density of timber, parallel compression to grain and bending, respectively; and ABNT NBR 7190 (1997) for the shear strength. The classification of the 80 laminate of timber with dimension of 6.0 x 1.5 x 220.0 cm were made by visual classification according to the American Standard ASTM D245 (2006) and by the modulus of elasticity – MOE (ASTM D4761 (2013)). Altogether, 20 beams of GLULAM were made, these formed by the combination of the laminated classified in the visual grades: Control (clear laminate), T1 (clear and special structural - SE), T2 (S1, S2, S3) and T3 (clear, SE, S1, S2, S3), the beams were evaluated by bending, tension perpendicular to grain and shear strength in the glued line. The results indicated the species as solid wood does not have the minimum resistance to be classified as C-20 by the ABNT NBR 7190 (1997), but the species was classified as structural grade in the C-16 by the EN 338 Standard. The GLULAM beams showed the minimum demanded values to the C-20 structural class according to the ABNT NBR 7190 (1997). The using of laminated with visually classified knots did not decrease the glulam beams strength when comparing to the beams made with laminated without knots.O objetivo foi avaliar as propriedades mecânicas da madeira, a influência da classificação visual de lâminas de Cryptomeria japonica D. Don no desempenho mecânico para uso em elementos estruturais em MLC, comparando com os requisitos mínimos exigidos pelas normas brasileira ABNT NBR 7190 (1997) e europeia EN 338 (2016). Os ensaios para caracterização física e mecânica da madeira sólida seguiram as recomendações das normas COPANT 461 (1972), 464 (1972) e 555 (1973) para densidade básica, resistência à compressão paralela às fibras e resistência à flexão estática, respectivamente; e ABNT NBR 7190 (1997) para resistência ao cisalhamento. As 80 lâminas de madeira foram produzidas com dimensões de 6,0 x 1,5 x 220,0 cm (largura x espessura x comprimento) e posteriormente classificadas visualmente conforme a norma americana ASTM D245 (2006) e pelo módulo de elasticidade - EW (ASTM D4761 (2013)). Ao todo, 20 vigas de MLC foram confeccionadas, sendo estas formadas pela combinação das lâminas classificadas nas classes visuais: Testemunha (lâminas limpas, ou seja, sem defeitos), T1 (limpas e estrutural especial - SE), T2 (S1, S2, S3) e T3 (limpas, SE, S1, S2, S3), as vigas foram avaliadas em testes mecânicos de resistência à flexão estática e resistências à tração normal às fibras e cisalhamento para linha de cola. Os resultados indicaram que como madeira sólida a espécie não apresentou resistência mínima para que seja classificada como C-20 pela ABNT NBR 7190 (1997), entretanto a espécie foi classificada como classe estrutural C-16 pela norma EN 338. As vigas de MLC apresentaram valores dentro do mínimo exigido para a classe C-20, conforme a ABNT NBR 7190 (1997). A utilização de lâminas com nós classificados visualmente não diminuiu a resistência das vigas de MLC quando comparado com vigas produzidas com lâminas sem nós
Diretrizes Brasileiras de Medidas da Pressão Arterial Dentro e Fora do Consultório – 2023
Hypertension is one of the primary modifiable risk factors for morbidity and mortality worldwide, being a major risk factor for coronary artery disease, stroke, and kidney failure. Furthermore, it is highly prevalent, affecting more than one-third of the global population.
Blood pressure measurement is a MANDATORY procedure in any medical care setting and is carried out by various healthcare professionals. However, it is still commonly performed without the necessary technical care. Since the diagnosis relies on blood pressure measurement, it is clear how important it is to handle the techniques, methods, and equipment used in its execution with care.
It should be emphasized that once the diagnosis is made, all short-term, medium-term, and long-term investigations and treatments are based on the results of blood pressure measurement. Therefore, improper techniques and/or equipment can lead to incorrect diagnoses, either underestimating or overestimating values, resulting in inappropriate actions and significant health and economic losses for individuals and nations.
Once the correct diagnosis is made, as knowledge of the importance of proper treatment advances, with the adoption of more detailed normal values and careful treatment objectives towards achieving stricter blood pressure goals, the importance of precision in blood pressure measurement is also reinforced.
Blood pressure measurement (described below) is usually performed using the traditional method, the so-called casual or office measurement. Over time, alternatives have been added to it, through the use of semi-automatic or automatic devices by the patients themselves, in waiting rooms or outside the office, in their own homes, or in public spaces. A step further was taken with the use of semi-automatic devices equipped with memory that allow sequential measurements outside the office (ABPM; or HBPM) and other automatic devices that allow programmed measurements over longer periods (HBPM).
Some aspects of blood pressure measurement can interfere with obtaining reliable results and, consequently, cause harm in decision-making. These include the importance of using average values, the variation in blood pressure during the day, and short-term variability. These aspects have encouraged the performance of a greater number of measurements in various situations, and different guidelines have advocated the use of equipment that promotes these actions. Devices that perform HBPM or ABPM, which, in addition to allowing greater precision, when used together, detect white coat hypertension (WCH), masked hypertension (MH), sleep blood pressure alterations, and resistant hypertension (RHT) (defined in Chapter 2 of this guideline), are gaining more and more importance.
Taking these details into account, we must emphasize that information related to diagnosis, classification, and goal setting is still based on office blood pressure measurement, and for this reason, all attention must be given to the proper execution of this procedure.La hipertensión arterial (HTA) es uno de los principales factores de riesgo modificables para la morbilidad y mortalidad en todo el mundo, siendo uno de los mayores factores de riesgo para la enfermedad de las arterias coronarias, el accidente cerebrovascular (ACV) y la insuficiencia renal. Además, es altamente prevalente y afecta a más de un tercio de la población mundial.
La medición de la presión arterial (PA) es un procedimiento OBLIGATORIO en cualquier atención médica o realizado por diferentes profesionales de la salud. Sin embargo, todavía se realiza comúnmente sin los cuidados técnicos necesarios. Dado que el diagnóstico se basa en la medición de la PA, es claro el cuidado que debe haber con las técnicas, los métodos y los equipos utilizados en su realización.
Debemos enfatizar que una vez realizado el diagnóstico, todas las investigaciones y tratamientos a corto, mediano y largo plazo se basan en los resultados de la medición de la PA. Por lo tanto, las técnicas y/o equipos inadecuados pueden llevar a diagnósticos incorrectos, subestimando o sobreestimando valores y resultando en conductas inadecuadas y pérdidas significativas para la salud y la economía de las personas y las naciones.
Una vez realizado el diagnóstico correcto, a medida que avanza el conocimiento sobre la importancia del tratamiento adecuado, con la adopción de valores de normalidad más detallados y objetivos de tratamiento más cuidadosos hacia metas de PA más estrictas, también se refuerza la importancia de la precisión en la medición de la PA.
La medición de la PA (descrita a continuación) generalmente se realiza mediante el método tradicional, la llamada medición casual o de consultorio. Con el tiempo, se han agregado alternativas a través del uso de dispositivos semiautomáticos o automáticos por parte del propio paciente, en salas de espera o fuera del consultorio, en su propia residencia o en espacios públicos. Se dio un paso más con el uso de dispositivos semiautomáticos equipados con memoria que permiten mediciones secuenciales fuera del consultorio (AMPA; o MRPA) y otros automáticos que permiten mediciones programadas durante períodos más largos (MAPA).
Algunos aspectos en la medición de la PA pueden interferir en la obtención de resultados confiables y, en consecuencia, causar daños en las decisiones a tomar. Estos incluyen la importancia de usar valores promedio, la variación de la PA durante el día y la variabilidad a corto plazo. Estos aspectos han alentado la realización de un mayor número de mediciones en diversas situaciones, y diferentes pautas han abogado por el uso de equipos que promuevan estas acciones. Los dispositivos que realizan MRPA o MAPA, que además de permitir una mayor precisión, cuando se usan juntos, detectan la hipertensión de bata blanca (HBB), la hipertensión enmascarada (HM), las alteraciones de la PA durante el sueño y la hipertensión resistente (HR) (definida en el Capítulo 2 de esta guía), están ganando cada vez más importancia.
Teniendo en cuenta estos detalles, debemos enfatizar que la información relacionada con el diagnóstico, la clasificación y el establecimiento de objetivos todavía se basa en la medición de la presión arterial en el consultorio, y por esta razón, se debe prestar toda la atención a la ejecución adecuada de este procedimiento.A hipertensão arterial (HA) é um dos principais fatores de risco modificáveis para morbidade e mortalidade em todo o mundo, sendo um dos maiores fatores de risco para doença arterial coronária, acidente vascular cerebral (AVC) e insuficiência renal. Além disso, é altamente prevalente e atinge mais de um terço da população mundial.
A medida da PA é procedimento OBRIGATÓRIO em qualquer atendimento médico ou realizado por diferentes profissionais de saúde. Contudo, ainda é comumente realizada sem os cuidados técnicos necessários. Como o diagnóstico se baseia na medida da PA, fica claro o cuidado que deve haver com as técnicas, os métodos e os equipamentos utilizados na sua realização.
Deve-se reforçar que, feito o diagnóstico, toda a investigação e os tratamentos de curto, médio e longo prazos são feitos com base nos resultados da medida da PA. Assim, técnicas e/ou equipamentos inadequados podem levar a diagnósticos incorretos, tanto subestimando quanto superestimando valores e levando a condutas inadequadas e grandes prejuízos à saúde e à economia das pessoas e das nações.
Uma vez feito o diagnóstico correto, na medida em que avança o conhecimento da importância do tratamento adequado, com a adoção de valores de normalidade mais detalhados e com objetivos de tratamento mais cuidadosos no sentido do alcance de metas de PA mais rigorosas, fica também reforçada a importância da precisão na medida da PA.
A medida da PA (descrita a seguir) é habitualmente feita pelo método tradicional, a assim chamada medida casual ou de consultório. Ao longo do tempo, foram agregadas alternativas a ela, mediante o uso de equipamentos semiautomáticos ou automáticos pelo próprio paciente, nas salas de espera ou fora do consultório, em sua própria residência ou em espaços públicos. Um passo adiante foi dado com o uso de equipamentos semiautomáticos providos de memória que permitem medidas sequenciais fora do consultório (AMPA; ou MRPA) e outros automáticos que permitem medidas programadas por períodos mais prolongados (MAPA).
Alguns aspectos na medida da PA podem interferir na obtenção de resultados fidedignos e, consequentemente, causar prejuízo nas condutas a serem tomadas. Entre eles, estão: a importância de serem utilizados valores médios, a variação da PA durante o dia e a variabilidade a curto prazo. Esses aspectos têm estimulado a realização de maior número de medidas em diversas situações, e as diferentes diretrizes têm preconizado o uso de equipamentos que favoreçam essas ações. Ganham cada vez mais espaço os equipamentos que realizam MRPA ou MAPA, que, além de permitirem maior precisão, se empregados em conjunto, detectam a HA do avental branco (HAB), HA mascarada (HM), alterações da PA no sono e HA resistente (HAR) (definidos no Capítulo 2 desta diretriz).
Resguardados esses detalhes, devemos ressaltar que as informações relacionadas a diagnóstico, classificação e estabelecimento de metas ainda são baseadas na medida da PA de consultório e, por esse motivo, toda a atenção deve ser dada à realização desse procedimento