35 research outputs found

    One-Step Synthesis of Copper and Cupric Oxide Particles from the Liquid Phase by X-Ray Radiolysis Using Synchrotron Radiation

    Get PDF
    The deposition of copper (Cu) and cupric oxide (Cu4O3, Cu2O, and CuO) particles in an aqueous copper sulfate (CuSO4) solution with additive alcohol such as methanol, ethanol, 2-propanol, and ethylene glycol has been studied by X-ray exposure from synchrotron radiation. An attenuated X-ray radiation time of 5 min allows for the synthesis of Cu, Cu4O3, Cu2O, and CuO nano/microscale particles and their aggregation into clusters. The morphology and composition of the synthesized Cu/cupric oxide particle clusters were characterized by scanning electron microscopy, scanning transmission electron microscopy, and high-resolution transmission electron microscopy with energy dispersive X-ray spectroscopy. Micro-Raman spectroscopy revealed that the clusters comprised cupric oxide core particles covered with Cu particles. Neither Cu/cupric oxide particles nor their clusters were formed without any alcohol additives. The effect of alcohol additives is attributed to the following sequential steps: photochemical reaction due to X-ray irradiation induces nucleation of the particles accompanying redox reaction and forms a cluster or aggregates by LaMer process and DLVO interactions. The procedure offers a novel route to synthesize the Cu/cupric oxide particles and aggregates. It also provides a novel additive manufacturing process or lithography of composite materials such as metal, oxide, and resin

    Fine-pitch and thick-foil gas electron multipliers for cosmic x-ray polarimeters

    Get PDF
    We have produced various gas electron multiplier foils (GEMs) by using laser etching technique for cosmic X-ray polarimeters. The finest structure GEM we have fabricated has 30 μm-diameter holes on a 50 μm-pitch. The effective gain of the GEM reaches around 5000 at the voltage of 570 V between electrodes. The gain is slightly higher than that of the CERN standard GEM with 70 μm-diameter holes on a 140 μm-pitch. We have fabricated GEMs with thickness of 100 μm which has two times thicker than the standard GEM. The effective gain of the thick-foil GEM is 104 at the applied voltage of 350 V per 50 μm of thickness. The gain is about two orders higher than that of the standard GEM. The remarkable characteristic of the thick-foil GEM is that the effective gain at the beginning of micro-discharge is quite improved. For fabricating the thick-foil GEMs, we have employed new material, liquid crystal polymer (LCP) which has little moisture absorption rate, as an insulator layer instead of polyimide. One of the thick-foil GEM we have fabricated has 8 μm copper layer in the middle of the 100 μm-thick insulator layer. The metal layer in the middle of the foil works as a field-shaper in the multiplication channels, though it slightly decreases the effective gain

    Development of cosmic x-ray polarimeter

    Get PDF
    We present a performance study of a cosmic X-ray polarimeter which is based on the photoelectric effect in gas, and sensitive to a few to 30 keV range. In our polarimeter, the key device would be the 50 μm pitch Gas Electron Multiplier (GEM). We have evaluated the modulation factor using highly polarized X-ray, provided by a synchrotron accelerator. In the analysis, we selected events by the eccentricity of the charge cloud of the photoelectron track. As a result, we obtained the relationship between the selection criteria for the eccentricity and the modulation factors; for example, when we selected the events which have their eccentricity of > 0.95, the polarimeter exhibited with the modulation factor of 0.32. In addition, we estimated the Minimum Detectable Polarization degree (MDP) of Crab Nebula with our polarimeter and found 10 ksec observation is enough to detect the polarization, if we adopt suitable X-ray mirrors

    Prognosis factors in the treatment of bisphosphonate-related osteonecrosis of the jaw - Prognostic factors in the treatment of BRONJ -

    Get PDF
    Objectives: Bisphosphonate-related osteonecrosis of the jaw (BRONJ) is a relatively rare but serious side effect of bisphosphonate (BP)-based treatments. This retrospective study aimed to investigate the risk factors and predictive markers in cases where patients were refractory to a recommended conservative treatment offered in our hospital. Patients and Methods: This single-center study collated the medical records of all patients treated for BRONJ between 2004 and 2011. A complete medical history, including detailed questionnaires, was collected for all patients, focusing on identifying underlying risk factors, clinical features, location and bone marker levels of BRONJ. Results: The mean BRONJ remission rate was 57.6%, and the median duration of remission was seven months. Eighteen patients (34.6%) had persistent or progressive disease with a recommended conservative treatment for BRONJ. Notably, urinary cross-linked N-terminal telopeptide of type 1 collagen (NTX) levels in those resistant to conservative treatment tended to be lower than in patients that healed well. Conclusions: We confirm that a significant proportion of BRONJ sufferers are refractory to a recommended conservative treatment and find that anticancer drugs, periodontal disease, the level of bone exposure and the dosage of intravenous BPs (e.g. zoledronate) represent specific risk factors in BRONJ that may determine the success of a recommended conservative treatment. Additionally, the NTX levels might be able to be a prognostic factor for the conservative treatment of BRONJ; additional research is necessary

    Fine-pitch and thick-foil gas electron multipliers for cosmic x-ray polarimeters

    Get PDF
    We have produced various gas electron multiplier foils (GEMs) by using laser etching technique for cosmic X-ray polarimeters. The finest structure GEM we have fabricated has 30 μm-diameter holes on a 50 μm-pitch. The effective gain of the GEM reaches around 5000 at the voltage of 570 V between electrodes. The gain is slightly higher than that of the CERN standard GEM with 70 μm-diameter holes on a 140 μm-pitch. We have fabricated GEMs with thickness of 100 μm which has two times thicker than the standard GEM. The effective gain of the thick-foil GEM is 104 at the applied voltage of 350 V per 50 μm of thickness. The gain is about two orders higher than that of the standard GEM. The remarkable characteristic of the thick-foil GEM is that the effective gain at the beginning of micro-discharge is quite improved. For fabricating the thick-foil GEMs, we have employed new material, liquid crystal polymer (LCP) which has little moisture absorption rate, as an insulator layer instead of polyimide. One of the thick-foil GEM we have fabricated has 8 μm copper layer in the middle of the 100 μm-thick insulator layer. The metal layer in the middle of the foil works as a field-shaper in the multiplication channels, though it slightly decreases the effective gain

    Development of cosmic x-ray polarimeter

    Get PDF
    We present a performance study of a cosmic X-ray polarimeter which is based on the photoelectric effect in gas, and sensitive to a few to 30 keV range. In our polarimeter, the key device would be the 50 μm pitch Gas Electron Multiplier (GEM). We have evaluated the modulation factor using highly polarized X-ray, provided by a synchrotron accelerator. In the analysis, we selected events by the eccentricity of the charge cloud of the photoelectron track. As a result, we obtained the relationship between the selection criteria for the eccentricity and the modulation factors; for example, when we selected the events which have their eccentricity of > 0.95, the polarimeter exhibited with the modulation factor of 0.32. In addition, we estimated the Minimum Detectable Polarization degree (MDP) of Crab Nebula with our polarimeter and found 10 ksec observation is enough to detect the polarization, if we adopt suitable X-ray mirrors

    Monitor of All-sky X-ray Image (MAXI)

    Get PDF
    Abstract. Monitor of All-sky X-ray Image (MAXI) is the first astrophysical payload which will be mounted on the Japanese Experiment Module (JEM) Exposed Facility in 2004. It is an X-ray all-sky monitor with unprecedented sensitivity to watch the activities of the X-ray sources in the whole sky in every 90 minutes. MAXI is boxshaped in 0.8 x 1.0 x 1.85 m with the weight of 500 kg. The mission life will be at least 2 years. MAXI has two fan-like field of views (FOV), 160 x 1.5 degree each. The X-ray instruments are Gas Slit Camera (GSC) and Solid-state Slit Camera (SSC). The GSC uses gas one-dimensional position sensitive proportional counters with 5340 cm 2 effective area in total and the SSC uses CCDs with 200 cm 2 . Both are capable to detect one-dimensional image, which is used to obtain the locations of the X-ray sources in the FOV along the long direction. Together with the scan which determine the other direction, MAXI can scan almost all sky with a precision of better than 1 degree in the energy range of 0.5-30 keV. The CCD is electrically cooled to -60°C and the camera body is radiatively cooled to -20°C. The CCD chip itself and the radiators may suffer contamination problem. The continuous Ethernet down link will enable us to alert the astronomers in all over the world to the appearance of X-ray transients, novae, bursts, flares etc. We made a test counter and test chips in 1998. Those are being tested in RIKEN, NASDA and Osaka-university. In this paper the test results will be presented, as well as the general description of the MAXI mission
    corecore