12 research outputs found

    Influence of metal alloy and the profile of coronary stents in patients with multivessel coronary disease

    Get PDF
    BACKGROUND: In Brazil, despite the recommendations of the Brazilian Society of Hemodynamics and Interventional Cardiology, the National Health System has not yet approved the use of drug-eluting stents. In percutaneous coronary interventions performed in the public and part of the private health care system, bare metal stents are used as the only option. Therefore, new information on bare metal stents is of great importance. The primary endpoint was to evaluate the influence of the alloy and the profile of coronary stents on late loss and restenosis rates 6 months after implantation in patients with multivessel coronary disease. METHODS: Single center, randomized and prospective study comparison of cobalt-chromium versus stainless steel stent implantation in 187 patients with multivessel coronary disease. At least one cobalt-chromium and one stainless steel stent were implanted per patient. RESULTS: Mean age of patients was 59.5 + 10.1 years with a prevalence of males (66.3%) and patients with acute coronary syndrome (56%). Baseline clinical characteristics were similar with hypertension in 146 (78%), dyslipidemia in 85 (45.5%) and diabetes in 68 (36.4%). Two hundred and twenty-nine cobalt-chromium and 284 stainless steel stents were implanted. Angiographic variables showed no statistically significant difference. Angiographic follow-up to 6 months after implantation showed similar late loss and restenosis rates. CONCLUSION: The use of two different alloys, stainless steel and cobalt-chrome stents, in the same patient and in the same vessel produced similar 6-month restenosis and late loss rates

    Influence of metal alloy and the profile of coronary stents in patients with multivessel coronary disease

    Get PDF
    BACKGROUND: In Brazil, despite the recommendations of the Brazilian Society of Hemodynamics and Interventional Cardiology, the National Health System has not yet approved the use of drug-eluting stents. In percutaneous coronary interventions performed in the public and part of the private health care system, bare metal stents are used as the only option. Therefore, new information on bare metal stents is of great importance. The primary endpoint was to evaluate the influence of the alloy and the profile of coronary stents on late loss and restenosis rates 6 months after implantation in patients with multivessel coronary disease. METHODS: Single center, randomized and prospective study comparison of cobalt-chromium versus stainless steel stent implantation in 187 patients with multivessel coronary disease. At least one cobalt-chromium and one stainless steel stent were implanted per patient. RESULTS: Mean age of patients was 59.5 + 10.1 years with a prevalence of males (66.3%) and patients with acute coronary syndrome (56%). Baseline clinical characteristics were similar with hypertension in 146 (78%), dyslipidemia in 85 (45.5%) and diabetes in 68 (36.4%). Two hundred and twenty-nine cobalt-chromium and 284 stainless steel stents were implanted. Angiographic variables showed no statistically significant difference. Angiographic follow-up to 6 months after implantation showed similar late loss and restenosis rates. CONCLUSION: The use of two different alloys, stainless steel and cobalt-chrome stents, in the same patient and in the same vessel produced similar 6-month restenosis and late loss rates

    Trombose coronariana tardia secundária a implante de stent com paclitaxel sem reestenose dos stents convencionais

    No full text
    Homem de 39 anos com angina pós-infarto. Coronariografia demonstrou: obstrução total proximal da artéria coronária direita (ACD), lesões obstrutivas de 95% na artéria descendente anterior (ADA), 80% no 2° ramo marginal esquerdo (ME) e 95% na artéria circunflexa (ACX). O paciente foi submetido a implante de stent TAXUS 3,0 x 24 mm e stent EXPRESS 2,75 x 24 mm nos terços proximal e distal da ACD, respectivamente, e stent INFINNIUM 3,0 x 24 mm na ADA com sucesso. Após 7 meses, apresentou IAM anterior por trombose do stent INFINNIUM e reestenose do stent TAXUS, sem perda de resultado nos stents convencionais
    corecore