330 research outputs found

    Implementation of Integrated Learning Program in neurosciences during first year of traditional medical course: Perception of students and faculty

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Our college introduced an integrated learning program (ILP) for first year undergraduates with an aim to develop, implement and evaluate a module for CNS in basic sciences and to assess the feasibility of an ILP in phase I of medical education in a college following traditional medical curriculum.</p> <p>Methods</p> <p>The idea of implementing ILP for Central Nervous System (CNS) in phase one was conceived by curriculum development committee drawn from faculty of all phases. After a series of meetings of curriculum development committee, inputs from basic science and clinical departments, a time table was constructed. Various teaching learning methods, themes for integrated didactic lectures, case based learning and clinical exposure were decided. Basic science faculty were made to participate actively in both case based learning and hospital visits along with clinical experts. The completed program was evaluated based on structured questionnaire.</p> <p>Results</p> <p>Sixty percent students rated the program good to excellent with reference to appreciation, understanding and application of basic science knowledge in health and disease. Seventy eight percent felt that this program will help them perform better in later days of clinical training. However sixty percent students felt that ILP will not help them perform better at the first professional examination. Seventy two per cent of faculty agreed that this program improved understanding and application of basic science knowledge of students. Ninety percent of faculty felt that this program will help them perform better in later days of clinical training.</p> <p>Conclusion</p> <p>The adoption of present integrated module for CNS and the use of multiple teaching learning methods have been proven to be useful in acquisition of knowledge from the student satisfaction point of view. Students and faculty expressed an overall satisfaction towards ILP for CNS. The study showed that it is possible to adopt an integrated learning module in the first year of medical course under a conventional curriculum.</p

    Evolution and spread of Venezuelan equine encephalitis complex alphavirus in the Americas.

    Get PDF
    Venezuelan equine encephalitis (VEE) complex alphaviruses are important re-emerging arboviruses that cause life-threatening disease in equids during epizootics as well as spillover human infections. We conducted a comprehensive analysis of VEE complex alphaviruses by sequencing the genomes of 94 strains and performing phylogenetic analyses of 130 isolates using complete open reading frames for the nonstructural and structural polyproteins. Our analyses confirmed purifying selection as a major mechanism influencing the evolution of these viruses as well as a confounding factor in molecular clock dating of ancestors. Times to most recent common ancestors (tMRCAs) could be robustly estimated only for the more recently diverged subtypes; the tMRCA of the ID/IAB/IC/II and IE clades of VEE virus (VEEV) were estimated at ca. 149–973 years ago. Evolution of the IE subtype has been characterized by a significant evolutionary shift from the rest of the VEEV complex, with an increase in structural protein substitutions that are unique to this group, possibly reflecting adaptation to its unique enzootic mosquito vector Culex (Melanoconion) taeniopus. Our inferred tree topologies suggest that VEEV is maintained primarily in situ, with only occasional spread to neighboring countries, probably reflecting the limited mobility of rodent hosts and mosquito vectors

    A Comparative Assessment of Non-Laboratory-Based versus Commonly Used Laboratory-Based Cardiovascular Disease Risk Scores in the NHANES III Population

    Get PDF
    National and international primary CVD risk screening guidelines focus on using total CVD risk scores. Recently, we developed a non-laboratory-based CVD risk score (inputs: age, sex, smoking, diabetes, systolic blood pressure, treatment of hypertension, body-mass index), which can assess risk faster and at lower costs compared to laboratory-based scores (inputs include cholesterol values). We aimed to assess the exchangeability of the non-laboratory-based risk score to four commonly used laboratory-based scores (Framingham CVD [2008, 1991 versions], and Systematic COronary Risk Evaluation [SCORE] for low and high risk settings) in an external validation population.Analyses were based on individual-level, score-specific rankings of risk for adults in the Third National Health and Nutrition Examination Survey (NHANES III) aged 25–74 years, without history of CVD or cancer (n = 5,999). Risk characterization agreement was based on overlap in dichotomous risk characterization (thresholds of 10-year risk >10–20%) and Spearman rank correlation. Risk discrimination was assessed using receiver operator characteristic curve analysis (10-year CVD death outcome). Risk characterization agreement ranged from 91.9–95.7% and 94.2–95.1% with Spearman correlation ranges of 0.957–0.980 and 0.946–0.970 for men and women, respectively. In men, c-statistics for the non-laboratory-based, Framingham (2008, 1991), and SCORE (high, low) functions were 0.782, 0.776, 0.781, 0.785, and 0.785, with p-values for differences relative to the non-laboratory-based score of 0.44, 0.89, 0.68 and 0.65, respectively. In women, the corresponding c-statistics were 0.809, 0.834, 0.821, 0.792, and 0.792, with corresponding p-values of 0.04, 0.34, 0.11 and 0.09, respectively.Every score discriminated risk of CVD death well, and there was high agreement in risk characterization between non-laboratory-based and laboratory-based risk scores, which suggests that the non-laboratory-based score can be a useful proxy for Framingham or SCORE functions in resource-limited settings. Future external validation studies can assess whether the sex-specific risk discrimination results hold in other populations

    Involving Citizen Scientists in Biodiversity Observation

    Get PDF
    The involvement of non-professionals in scientific research and environmental monitoring, termed Citizen Science (CS), has now become a mainstream approach for collecting data on earth processes, ecosystems and biodiversity. This chapter examines how CS might contribute to ongoing efforts in biodiversity monitoring, enhancing observation and recording of key species and systems in a standardised manner, thereby supporting data relevant to the Essential Biodiversity Variables (EBVs), as well as reaching key constituencies who would benefit Biodiversity Observation Networks (BONs). The design of successful monitoring or observation networks that rely on citizen observers requires a careful balancing of the two primary user groups, namely data users and data contributors (i.e., citizen scientists). To this end, this chapter identifies examples of successful CS programs as well as considering practical issues such as the reliability of the data, participant recruitment and motivation, and the use of emerging technologies

    The search for transient astrophysical neutrino emission with IceCube-DeepCore

    Get PDF
    We present the results of a search for astrophysical sources of brief transient neutrino emission using IceCube and DeepCore data acquired between 2012 May 15 and 2013 April 30. While the search methods employed in this analysis are similar to those used in previous IceCube point source searches, the data set being examined consists of a sample of predominantly sub-TeV muon-neutrinos from the Northern Sky (-5 degrees < delta < 90 degrees) obtained through a novel event selection method. This search represents a first attempt by IceCube to identify astrophysical neutrino sources in this relatively unexplored energy range. The reconstructed direction and time of arrival of neutrino events are used to search for any significant self-correlation in the data set. The data revealed no significant source of transient neutrino emission. This result has been used to construct limits at timescales ranging from roughly 1 s to 10 days for generic soft-spectra transients. We also present limits on a specific model of neutrino emission from soft jets in core-collapse supernovae

    Reliability of goniometric measurements in children with cerebral palsy: A comparative analysis of universal goniometer and electronic inclinometer. A pilot study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Even though technological progress has provided us with more and more sophisticated equipment for making goniometric measurements, the most commonly used clinical tools are still the universal goniometer and, to a lesser extent, the inclinometer. There is, however, no published study so far that uses an inclinometer for measurements in children with cerebral palsy (CP). The objective of this study was two-fold: to independently assess the intra and inter-examiner reliability for measuring the hip abduction range of motion in children with CP using two different instruments, the universal two-axis goniometer and electronic inclinometer. A pool of 5 examiners with different levels of experience as paediatric physiotherapists participated. The study did not compare both instruments because the measurement procedure and the hip position were different for each.</p> <p>Methods</p> <p>A prospective, observational study of goniometery was carried out with 14 lower extremities of 7 children with spastic CP. The inclinometer study was carried out with 8 lower extremities of 4 children with spastic CP. This study was divided into two independent parts: a study of the reliability of the hip abduction range of motion measured with a universal goniometer (hip at 0° flexion) and with an electronic inclinometer (hip at 90° flexion). The Intraclass Correlation Coefficient (ICC) was calculated to analyse intra and inter-examiner agreement for each instrument.</p> <p>Results</p> <p>For the goniometer, the intra-examiner reliability was excellent (>0.80), while the inter-examiner reliability was low (0.375 and 0.475). For the inclinometer, both the intra-examiner (0.850-0.975) and inter-examiner reliability were excellent (0.965 and 0.979).</p> <p>Conclusions</p> <p>The inter-examiner reliability for goniometric measurement of hip abduction in children with CP was low, in keeping with other results found in previous publications. The inclinometer has proved to be a highly reliable tool for measuring the hip abduction range of motion in children with CP, which opens up new possibilities in this field, despite having some measurement limitations.</p

    The Alzheimer's Disease Prediction Of Longitudinal Evolution (TADPOLE) Challenge: Results after 1 Year Follow-up

    Get PDF
    We present the findings of "The Alzheimer's Disease Prediction Of Longitudinal Evolution" (TADPOLE) Challenge, which compared the performance of 92 algorithms from 33 international teams at predicting the future trajectory of 219 individuals at risk of Alzheimer's disease. Challenge participants were required to make a prediction, for each month of a 5-year future time period, of three key outcomes: clinical diagnosis, Alzheimer's Disease Assessment Scale Cognitive Subdomain (ADAS-Cog13), and total volume of the ventricles. No single submission was best at predicting all three outcomes. For clinical diagnosis and ventricle volume prediction, the best algorithms strongly outperform simple baselines in predictive ability. However, for ADAS-Cog13 no single submitted prediction method was significantly better than random guessing. Two ensemble methods based on taking the mean and median over all predictions, obtained top scores on almost all tasks. Better than average performance at diagnosis prediction was generally associated with the additional inclusion of features from cerebrospinal fluid (CSF) samples and diffusion tensor imaging (DTI). On the other hand, better performance at ventricle volume prediction was associated with inclusion of summary statistics, such as patient-specific biomarker trends. The submission system remains open via the website https://tadpole.grand-challenge.org, while code for submissions is being collated by TADPOLE SHARE: https://tadpole-share.github.io/. Our work suggests that current prediction algorithms are accurate for biomarkers related to clinical diagnosis and ventricle volume, opening up the possibility of cohort refinement in clinical trials for Alzheimer's disease
    • …
    corecore