570 research outputs found
Local order measurement in SnGe alloys and monolayer Sn films on Si with reflection electron energy loss spectrometry
Measurements of local order are demonstrated in Sn-containing alloys and epitaxial monolayer thickness films by analysis of extended-edge energy loss fine structure (EXELFS) data obtained by reflection electron energy loss spectrometry (REELS). These measurements of short-range order provide a complement to the chemical information obtained with REELS and long-range order obtained using reflection high energy electron diffraction. The results suggest that EXELFS measurements are practical for samples mounted on the growth manipulator in a molecular beam epitaxy chamber. Advantages and limitations of reflection EXELFS are discussed
In situ reflection electron energy loss spectroscopy measurements of low temperature surface cleaning for Si molecular beam epitaxy
In situ analysis of hydrocarbon desorption from hydrogen terminated Si(100) surfaces was performed in a silicon molecular beam epitaxy system, using reflection electron energy loss spectroscopy, in conjunction with conventional reflection high energy electron diffraction analysis. Measurements of C K edge core loss intensities demonstrate that this method is sufficiently sensitive to enable in situ analysis of hydrocarbon desorption at fractional monolayer coverages during low-temperature isothermal anneals. Hydrocarbon desorption was found to begin at 115 °C, and at 200 °C complete desorption occurred within 10 min. Hydrocarbon coverage was not measurably affected by operation of ionization gauge filaments during low temperature anneals, but was increased by transient outgassing of the sample holder, and its environs
Cooperative WebLab in chemical engineering between France and Brazil: Validation of the methodology
A WebLab is an experiment operated remotely via Internet. Besides the strictly technical aspects of such an experiment, which may contribute to the learning of Chemical Engineering fundamentals, there is also important feedback when teams of students of two different countries are working together: the WebLab becomes an intercultural experience, enhancing the communication skills of the students. A WebLab between Universidade Federal de SĂŁo Carlos (DEQ/UFSCar) and the Ecole Nationale SupĂ©rieure dâIngĂ©nieurs en Arts Chimiques et Technologiques (ENSIACET) is presented in this work. A mass transfer experiment in a bench scale reactor (stirred and aerated) had to be studied by mixed teams, thus emulating challenges that will be common in future working environments. In order to perform the experiment, students in Brazil and in France were put into groups. The students had to make decisions about the procedure for executing the experiments. All the students were able to control the equipment, no matter where they were physically. Students communicated using video conference software. The students' and teachers' opinions of this experience were very positive. This methodology is an important contribution to the education of engineers in a world integrated by modern communication technologies
Serum Concentrations of Myostatin and Myostatin-Interacting Proteins do not differ between young and Scarcopenic elderly men
Peer reviewedPostprin
Detectors for the James Webb Space Telescope Near-Infrared Spectrograph I: Readout Mode, Noise Model, and Calibration Considerations
We describe how the James Webb Space Telescope (JWST) Near-Infrared
Spectrograph's (NIRSpec's) detectors will be read out, and present a model of
how noise scales with the number of multiple non-destructive reads
sampling-up-the-ramp. We believe that this noise model, which is validated
using real and simulated test data, is applicable to most astronomical
near-infrared instruments. We describe some non-ideal behaviors that have been
observed in engineering grade NIRSpec detectors, and demonstrate that they are
unlikely to affect NIRSpec sensitivity, operations, or calibration. These
include a HAWAII-2RG reset anomaly and random telegraph noise (RTN). Using real
test data, we show that the reset anomaly is: (1) very nearly noiseless and (2)
can be easily calibrated out. Likewise, we show that large-amplitude RTN
affects only a small and fixed population of pixels. It can therefore be
tracked using standard pixel operability maps.Comment: 55 pages, 10 figure
- âŠ