56 research outputs found

    Deep Placental Vessel Segmentation for Fetoscopic Mosaicking

    Get PDF
    During fetoscopic laser photocoagulation, a treatment for twin-to-twin transfusion syndrome (TTTS), the clinician first identifies abnormal placental vascular connections and laser ablates them to regulate blood flow in both fetuses. The procedure is challenging due to the mobility of the environment, poor visibility in amniotic fluid, occasional bleeding, and limitations in the fetoscopic field-of-view and image quality. Ideally, anastomotic placental vessels would be automatically identified, segmented and registered to create expanded vessel maps to guide laser ablation, however, such methods have yet to be clinically adopted. We propose a solution utilising the U-Net architecture for performing placental vessel segmentation in fetoscopic videos. The obtained vessel probability maps provide sufficient cues for mosaicking alignment by registering consecutive vessel maps using the direct intensity-based technique. Experiments on 6 different in vivo fetoscopic videos demonstrate that the vessel intensity-based registration outperformed image intensity-based registration approaches showing better robustness in qualitative and quantitative comparison. We additionally reduce drift accumulation to negligible even for sequences with up to 400 frames and we incorporate a scheme for quantifying drift error in the absence of the ground-truth. Our paper provides a benchmark for fetoscopy placental vessel segmentation and registration by contributing the first in vivo vessel segmentation and fetoscopic videos dataset.Comment: Accepted at MICCAI 202

    Measurement and Reproducibility of Preserved Ellipsoid Zone Area and Preserved Retinal Pigment Epithelium Area in Eyes With Choroideremia

    Get PDF
    PURPOSE: To identify valid and reproducible methods for quantifying anatomic outcome measures for eyes with choroideremia (CHM) in clinical trials. DESIGN: Reliability analysis study. METHODS: In this multicenter study, patients with confirmed genetic diagnosis of CHM were enrolled. All cases underwent spectral-domain optical coherence tomography (SDOCT) and fundus autofluorescence (FAF) imaging. Two graders independently delineated boundaries of preserved autofluorescence (PAF) and pre-served ellipsoid zone (EZ) on FAF and OCT images, respectively. The results of the 2 independent gradings of both FAF and OCT images were compared to assess the reproducibility of the grading methods. RESULTS: A total of 148 eyes from 75 cases were included. In 21% of eyes PAF and in 43% of eyes preserved EZ had extended beyond the image capture area. After exclusion of these eyes and low-quality images, 114 FAF and 77 OCT images were graded. The mean PAF areas from 2 independent gradings were 3.720 +/- 3.340 mm(2) and 3.692 +/- 3.253 mm2, respectively. Intraclass correlation coefficient (ICC) for these gradings was 0.996. The mean preserved EZ areas from 2 independent gradings were 2.746 +/- 2.319 mm2 and 2.858 2.446 mm2, respectively. ICC for these gradings was 0.991. CONCLUSIONS: Quantifying preserved retinal pigment epithelium and EZ areas on FAF and OCT images, respectively, in CHM patients is highly reproducible. These variables would be potential anatomic outcome measures for CHM clinical trials and could be studied and tracked longitudinally in choroideremia. (C) 2017 Elsevier Inc. All rights reserved.Peer reviewe

    SDOCT Imaging to Identify Macular Pathology in Patients Diagnosed with Diabetic Maculopathy by a Digital Photographic Retinal Screening Programme

    Get PDF
    INTRODUCTION: Diabetic macular edema (DME) is an important cause of vision loss. England has a national systematic photographic retinal screening programme to identify patients with diabetic eye disease. Grading retinal photographs according to this national protocol identifies surrogate markers for DME. We audited a care pathway using a spectral-domain optical coherence tomography (SDOCT) clinic to identify macular pathology in this subset of patients. METHODS: A prospective audit was performed of patients referred from screening with mild to moderate non-proliferative diabetic retinopathy (R1) and surrogate markers for diabetic macular edema (M1) attending an SDOCT clinic. The SDOCT images were graded by an ophthalmologist as SDOCT positive, borderline or negative. SDOCT positive patients were referred to the medical retina clinic. SDOCT negative and borderline patients were further reviewed in the SDOCT clinic in 6 months. RESULTS: From a registered screening population of 17 551 patients with diabetes mellitus, 311 patients met the inclusion criteria between (March 2008 and September 2009). We analyzed images from 311 patients' SDOCT clinic episodes. There were 131 SDOCT negative and 12 borderline patients booked for revisit in the OCT clinic. Twenty-four were referred back to photographic screening for a variety of reasons. A total of 144 were referred to ophthalmology with OCT evidence of definite macular pathology requiring review by an ophthalmologist. DISCUSSION: This analysis shows that patients with diabetes, mild to moderate non-proliferative diabetic retinopathy (R1) and evidence of diabetic maculopathy on non-stereoscopic retinal photographs (M1) have a 42.1% chance of having no macular edema on SDOCT imaging as defined by standard OCT definitions of DME when graded by a retinal specialist. SDOCT imaging is a useful adjunct to colour fundus photography in screening for referable diabetic maculopathy in our screening population

    Longitudinal Changes of Fixation Location and Stability Within 12 Months in Stargardt Disease: ProgStar Report No. 12

    Get PDF
    Purpose: To investigate the natural history of Stargardt disease (STGD1) using fixation location and fixation stability. // Design: Multicenter, international, prospective cohort study. // Methods: Fixation testing was performed using the Nidek MP-1 microperimeter as part of the prospective, multicenter, natural history study on the Progression of Stargardt disease (ProgStar). A total of 238 patients with ABCA4-related STGD1 were enrolled at baseline (bilateral enrollment in 86.6%) and underwent repeat testing at months 6 and 12. // Results: Outcome measures included the distance of the preferred retinal locus from the fovea (PRL) and the bivariate contour ellipse area (BCEA). After 12 months of follow-up, the change in the eccentricity of the PRL from the anatomic fovea was −0.0014 degrees (95% confidence interval [CI], −0.27 degrees, 0.27 degrees; P = .99). The deterioration in the stability of fixation as expressed by a larger BCEA encompassing 1 standard deviation of all fixation points was 1.21 degrees squared (deg2) (95% CI, −1.23 deg2, 3.65 deg2; P = .33). Eyes with increases and decreases in PRL eccentricity and/or BCEA values were observed. // Conclusions: Our observations point to the complexity of fixation parameters. The association of increasingly eccentric and unstable fixation with longer disease duration that is typically found in cross-sectional studies may be countered within individual patients by poorly understood processes like neuronal adaptation. Nevertheless, fixation parameters may serve as useful secondary outcome parameters in selected cases and for counseling patients to explain changes to their visual functionality

    Relationship between nerve fiber layer hemorrhages and outcomes in central retinal vein occlusion

    Get PDF
    PURPOSE. To evaluate the depth and pattern of retinal hemorrhage in acute central retinal vein occlusion (CRVO) and to correlate these with visual and anatomic outcomes. METHODS. Retinal hemorrhages were evaluated with color fundus photography and fluorescein angiography at baseline and follow-up. Snellen visual acuity (VA), central foveal thickness (CFT), extent of retinal ischemia, and development of neovascularization were analyzed. RESULTS. 108 eyes from 108 patients were evaluated. Mean age was 63.6 ± 16.1 years with a predilection for the right eye (73.1). Average follow-up was 17.2 ± 19.2 months. Mean VA at baseline was 20/126 and 20/80 at final follow-up. Baseline (P = 0.005) and final VA (P = 0.02) in eyes with perivascular nerve fiber layer (NFL) hemorrhages were significantly worse than in eyes with deep hemorrhages alone. Baseline CFT was greater in the group with perivascular hemorrhages (826 ± 394 μm) compared to the group with deep hemorrhages alone (455 ± 273 μm, P < 0.001). The 10 disc areas of retinal ischemia was more common in patients with perivascular (80.0) and peripapillary (31.3) versus deep hemorrhages alone (16.1, P < 0.001). Neovascularization of the iris was more common, although this differrence was not significant, in the groups with peripapillary (14.3) and perivascular (2.0) NFL versus deep hemorrhages alone (0.0). CONCLUSIONS. NFL retinal hemorrhages at baseline correlate with more severe forms of CRVO, with greater macular edema, poorer visual outcomes, and greater risk of ischemia and neovascularization. This may be related to the organization of the retinal capillary plexus. The depth and pattern of distribution of retinal hemorrhages in CRVO may provide an easily identifiable early biomarker of CRVO prognosis. Copyright 2020 The Author

    Dexamethasone intravitreal implant in previously treated patients with diabetic macular edema : Subgroup analysis of the MEAD study

    Get PDF
    Background: Dexamethasone intravitreal implant 0.7 mg (DEX 0.7) was approved for treatment of diabetic macular edema (DME) after demonstration of its efficacy and safety in the MEAD registration trials. We performed subgroup analysis of MEAD study results to evaluate the efficacy and safety of DEX 0.7 treatment in patients with previously treated DME. Methods: Three-year, randomized, sham-controlled phase 3 study in patients with DME, best-corrected visual acuity (BCVA) of 34.68 Early Treatment Diabetic Retinopathy Study letters (20/200.20/50 Snellen equivalent), and central retinal thickness (CRT) 65300 \u3bcm measured by time-domain optical coherence tomography. Patients were randomized to 1 of 2 doses of DEX (0.7 mg or 0.35 mg), or to sham procedure, with retreatment no more than every 6 months. The primary endpoint was 6515-letter gain in BCVA at study end. Average change in BCVA and CRT from baseline during the study (area-under-the-curve approach) and adverse events were also evaluated. The present subgroup analysis evaluated outcomes in patients randomized to DEX 0.7 (marketed dose) or sham based on prior treatment for DME at study entry. Results: Baseline characteristics of previously treated DEX 0.7 (n = 247) and sham (n=261) patients were similar. In the previously treated subgroup, mean number of treatments over 3 years was 4.1 for DEX 0.7 and 3.2 for sham, 21.5 % of DEX 0.7 patients versus 11.1 % of sham had 6515-letter BCVA gain from baseline at study end (P = 0.002), mean average BCVA change from baseline was +3.2 letters with DEX 0.7 versus +1.5 letters with sham (P = 0.024), and mean average CRT change from baseline was -126.1 \u3bcm with DEX 0.7 versus -39.0 \u3bcm with sham(P < 0.001). Cataract-related adverse events were reported in 70.3 % of baseline phakic patients in the previously treated DEX 0.7 subgroup; vision gains were restored following cataract surgery. Conclusions: DEX 0.7 significantly improved visual and anatomic outcomes in patients with DME previously treated with laser, intravitreal anti-vascular endothelial growth factor, intravitreal triamcinolone acetonide, or a combination of these therapies. The safety profile of DEX 0.7 in previously treated patients was similar to its safety profile in the total study population

    Comparison and Correlation of Retinal Sensitivity between Microperimetry and Standard Automated Perimetry in Low-Tension Glaucoma

    No full text
    Precis: Our study demonstrated that in low-tension glaucoma patients, MP3- and HFA- derived retinal sensitivities were similar and strongly correlated, allowing the respective data to be interrelated. Purpose: To compare and correlate retinal sensitivities obtained by Nidek Microperimetry-3 (MP-3) with those obtained from the Humphrey Field Analyzer (HFA) in eyes with low-tension glaucoma (LTG). Methods: In this prospective comparative study, 45 eyes of 24 LTG patients underwent retinal sensitivity assessments using the MP-3 (Nidek Technologies) and the HFA (Carl Zeiss Meditec) at the UCLA-Doheny Eye Center. Global and pointwise retinal sensitivity measurements were compared and correlated between the two devices. Results: No statistically significant differences (P=0.85) were noted between the mean retinal sensitivities determined by each device (MP-3: 26.33\ub14.31\u2592dB; range 13.05-31.60 vs. HFA: 26.42\ub13.98\u2592dB; range 17.17-30.96), and a strong correlation (r=0.66, P &lt; 0.001) was noted for retinal sensitivity measurements. In addition, moderate to strong correlations were observed between the mean retinal sensitivity derived by MP3 versus HFA-derived mean deviation (MD, r=0.57, P&lt;0.001), as well as, the pattern standard deviation (PSD, r=0.67, P&lt;0.001). The intraclass correlation coefficient was excellent (ICC=0.80, 95% CI 0.63 to 0.89), while the Bland-Altman analysis showed good agreement between the two devices with respect to retinal sensitivity. Conclusion: Retinal sensitivity measurements obtained by the MP-3 microperimetry instrument and the standard automated HFA perimeter were similar and highly correlated in patients with low tension glaucoma. Given the potential benefits of microperimetry technology such as auto-eye-tracking and potentially more precise structure-function correlations, the use of microperimetry to monitor visual function in glaucoma management warrants further consideration
    corecore