173 research outputs found

    Relative abundances of sub-iron to iron nuclei in low energy (50-250 MeV/N) cosmic rays as observed in the Skylab experiment

    Get PDF
    A Lexan polycarbonate detector exposed on the exterior of Skylab-3 for 73 days during a solar quiet period was used to study the relative abundances of calcium to nickel ions in low energy cosmic rays of 50 to 250 MeV/N. The method of charge identification is based on the measurement of conelength (L) and residual range (R) of these particles in various Lexan sheets. Since more than one cone (sometimes as many as five) is observed and is measured, the charge accuracy becomes precise and accurate. The ratio of (calcium to manganese) to (iron and cobalt) obtained at three energy intervals of 50 to 80, 80 to 150, 150 to 250 and 50 to 250 MeV/N are 7.6 plus or minus 3.8, 2.7 plus or minus 0.8, 1.4 plus or minus 0.6 and 3.3 plus or minus 0.7 respectively. These data thus indicate a large increase of this ratio with decreasing energy. The origin of this strong energy dependence is not understood at present

    Detector calibration of the Indian cosmic ray experiment (IONS) in Space-Shuttle Spacelab-13

    Get PDF
    In the Indian cosmic ray experiment (IONS) in Spacelab-3 the intention is to study nuclei up to iron in low energy cosmic rays, using CR-39 (DOP) detectors. CR-39 (DOP) was exposed to He4, C12, O16, Ne20, Si28, Ar40, Cr52 and Fe56 accelerated beams from various accelerator facilities available around the world. Different beam energies and exposure angles were used. From these exposures, the charge resolution and energy resolution for the detector in the region of interest were studied. The effect of pre-annealing and depth on the response of our detector was studied. For isotopic resolution, exposed the detector samples were exposed to Ne2O and Ne22 accelerated beams. Samples of CR-39 (DOP) exposed to different accelerated heavy ions were kept in the detector module to take into account the effect of ambient conditions on detector response during the flight

    Abundance of low energy (50-150 MeV) antiprotons in cosmic rays

    Get PDF
    The progress is presented of the nuclear emulsion experiment to determine abundance of low energy antiprotons in cosmic rays. No antiprotons have been detected so far at upper limit of p/p less than or similar to 4 x .0001 in the energy range 50 MeV to 15 MeV

    IONS (ANURADHA): Ionization states of low energy cosmic rays

    Get PDF
    IONS (ANURADHA), the experimental payload designed specifically to determine the ionization states, flux, composition, energy spectra and arrival directions of low energy (10 to 100 MeV/amu) anomalous cosmic ray ions of helium to iron in near-Earth space, had a highly successful flight and operation Spacelab-3 mission. The experiment combines the accuracy of a highly sensitive CR-39 nuclear track detector with active components included in the payload to achieve the experimental objectives. Post-flight analysis of detector calibration pieces placed within the payload indicated no measurable changes in detector response due to its exposure in spacelab environment. Nuclear tracks produced by alpha-particles, oxygen group and Fe ions in low energy anomalous cosmic rays were identified. It is calculated that the main detector has recorded high quality events of about 10,000 alpha-particles and similar number of oxygen group and heavier ions of low energy cosmic rays

    Observations of enhanced sub-iron (Sc-Cr) to iron abundance ratios in the low energy galactic cosmic rays in Spacelab-3 and their implications

    Get PDF
    The Anuradha cosmic ray experiment in Spacelab-3, flown in the orbit at 350 km with an inclination of 57° for about six days, was used to measure the low energy galactic cosmic ray (GCR) heavy ions using a specially designed CR-39 detector module incorporating the arrival time information of the particles. The abundances of sub-iron (Sc-Cr) and iron particles in the low energy interval of 30-300 MeV/N were determined from the measurements made in four different depths of the CR-39 detector module of 150 layers. From these studies we obtained sub-iron (Sc-Cr) to iron abundance ratios of 0.8 to 1.2 in 30-300 MeV/N energy range. It is found that these ratios are enhanced by a factor of two as compared to interplanetary ratios of about 0.5. It is shown that the enhancement of the ratio inside the earth's magnetosphere is probably due to the degree of ionization of low energy Sc to Cr and Fe ions in the galactic cosmic rays and to the rigidity filtering effects of the geomagnetic field. Further studies are needed to understand fully the phenomena and their implications

    Anomalous Cosmic Rays and their Ionization States

    Get PDF
    Ionization states of 16 individual anomalous cosmic ray events have been determined in the anuradha cosmic ray experiment conducted onboard Spacelab-3. The geomagnetic field was used as a rigidity filter for the energetic charged particles, and the upper limit on their ionization states is obtained by using the relation Z <= M.p.c/R/sub c/. Out of 16 events, 11 are found to be singly ionized and the other five events are consistent with their being in singly ionized states. The singly ionized nature of the anomalous cosmic ray particles suggests neutrals in the local interstellar space as their source

    ICONE14-89685 MODELLING OF IRRADIATED MATERIALS

    Get PDF
    ABSTRACT Irradiation of materials by energetic particles causes significant degradation of the mechanical properties, most notably an increased yield stress and decrease ductility, thus limiting lifetime of materials used in nuclear reactors. The microstructure of irradiated materials evolves over a wide range of length and time scales, making radiation damage and inherently multi-scale phenomenon. At atomic length scale, the principal sources of radiation damage are the primary knock-on atoms that recoil under collision from energetic particles such as neutrons or ions. These knock-on atoms in turn produce vacancies and self-interstitial atoms, and stacking fault tetrahedra. At higher length scale, these defect clusters form loops around existing dislocations, leading to their decoration and immobilization, which ultimately leads to radiation hardening in most of the materials. All these defects finally effect the macroscopic mechanical and other properties. An attempt is made to understand these phenomena using molecular dynamics studies and discrete dislocation dynamics modelling. INTRODUCTION The microstructure of irradiated materials evolves over a wide range of length and time scales, making radiation damage and inherently multi-scale phenomenon. The primary source of damage in the irradiated material is the displacement cascades generated by the primary knock-on atom (PKA) recoiled under the collision with the energetic particle. The spectrum of energy acquired by recoiled PKA is very wide ranging from few hundred electronvolts to tens of kiloelectronvolts. The number of atoms perturbed by primary and secondary collisions depends upon recoil energy of the PKA and can reach up to few thousands. The recoiled energy of the PKA is dissipated in the lattice and if the KE of PKA is sufficiently higher it results in the formation of heated core and hundreds of atoms displaced from their equilibrium lattice position. Temperatur

    Assessment of endothelial function by brachial artery flow mediated dilatation in microvascular disease

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Cardiac syndrome X is an important therapeutic and diagnostic challenge to physician. Study of Csx patients may help to understand the pathophysiology of coronary microcirculation and to gain an insight on the management of these group patients.</p> <p>Methods</p> <p>We measured the flow mediated dilation of the brachial artery both endothelium dependent and independent vasodilatation by high resolution ultrasound in 30 cardiac syndrome X patients and matched with 30 healthy control subjects.</p> <p>Results</p> <p>Significantly decreased flow mediated dilatation was observed in patients when compared to control (9.42 ± 7.20 vs 21.11 ± 9.16 p < 0.01) but no significant difference was observed between groups in response to nitroglycerin (25.39 ± 6.82 vs 28.87 ± 8.69). Receiver operator characteristic analysis showed that value of < 11.11 had sensitivity of 80%, specificity 86.67%, positive predictive value 76.66%, negative predictive value 83.33%. In total, 46% of subjects had endothelial dysfunction and of them, CSX subjects had higher prevalence (76% vs 16% p < 0.01) than control subjects. Higher mean values of body mass index, systolic blood pressure and diastolic blood pressure was observed in subjects with FMD < 11.11 than > 11.11(p < 0.01). In logistic regression analysis, FMD was significantly associated with systolic blood pressure (Odds ratio 1.122 95% CI 1.053-1.196 p < 0.01) and body mass index (Odds 1.248 95%CI 0.995-1.56 p < 0.05).</p> <p>Conclusions</p> <p>The study suggests impairment of endothelial function in cardiac syndrome X patients. Increased Systolic blood pressure and body mass index may increase the risk of impairment of endothelial function in this group of patients.</p

    Why Are Outcomes Different for Registry Patients Enrolled Prospectively and Retrospectively? Insights from the Global Anticoagulant Registry in the FIELD-Atrial Fibrillation (GARFIELD-AF).

    Get PDF
    Background: Retrospective and prospective observational studies are designed to reflect real-world evidence on clinical practice, but can yield conflicting results. The GARFIELD-AF Registry includes both methods of enrolment and allows analysis of differences in patient characteristics and outcomes that may result. Methods and Results: Patients with atrial fibrillation (AF) and ≥1 risk factor for stroke at diagnosis of AF were recruited either retrospectively (n = 5069) or prospectively (n = 5501) from 19 countries and then followed prospectively. The retrospectively enrolled cohort comprised patients with established AF (for a least 6, and up to 24 months before enrolment), who were identified retrospectively (and baseline and partial follow-up data were collected from the emedical records) and then followed prospectively between 0-18 months (such that the total time of follow-up was 24 months; data collection Dec-2009 and Oct-2010). In the prospectively enrolled cohort, patients with newly diagnosed AF (≤6 weeks after diagnosis) were recruited between Mar-2010 and Oct-2011 and were followed for 24 months after enrolment. Differences between the cohorts were observed in clinical characteristics, including type of AF, stroke prevention strategies, and event rates. More patients in the retrospectively identified cohort received vitamin K antagonists (62.1% vs. 53.2%) and fewer received non-vitamin K oral anticoagulants (1.8% vs . 4.2%). All-cause mortality rates per 100 person-years during the prospective follow-up (starting the first study visit up to 1 year) were significantly lower in the retrospective than prospectively identified cohort (3.04 [95% CI 2.51 to 3.67] vs . 4.05 [95% CI 3.53 to 4.63]; p = 0.016). Conclusions: Interpretations of data from registries that aim to evaluate the characteristics and outcomes of patients with AF must take account of differences in registry design and the impact of recall bias and survivorship bias that is incurred with retrospective enrolment. Clinical Trial Registration: - URL: http://www.clinicaltrials.gov . Unique identifier for GARFIELD-AF (NCT01090362)
    corecore