57 research outputs found

    Random variation in rectal position during radiotherapy for prostate cancer is two to three times greater than that predicted from prostate motion.

    Get PDF
    OBJECTIVE: Radiotherapy for prostate cancer does not explicitly take into account daily variation in the position of the rectum. It is important to accurately assess accumulated dose (DA) to the rectum in order to understand the relationship between dose and toxicity. The primary objective of this work was to quantify systematic (Σ) and random (σ) variation in the position of the rectum during a course of prostate radiotherapy. METHODS: The rectum was manually outlined on the kilo-voltage planning scan and 37 daily mega-voltage image guidance scans for 10 participants recruited to the VoxTox study. The femoral heads were used to produce a fixed point to which all rectal contours were referenced. RESULTS: Σ [standard deviation (SD) of means] between planning and treatment was 4.2 mm in the anteroposterior (AP) direction and 1.3 mm left-right (LR). σ (root mean square of SDs) was 5.2 mm AP and 2.7 mm LR. Superior-inferior variation was less than one slice above and below the planning position. CONCLUSION: Our results for Σ are in line with published data for prostate motion. σ, however, was approximately twice as great as that seen for prostate motion. This suggests that DA may differ from planned dose in some patients treated with radiotherapy for prostate cancer. ADVANCES IN KNOWLEDGE: This work is the first to use daily imaging to quantify Σ and σ of the rectum in prostate cancer. σ was found to be greater than published data, providing strong rationale for further investigation of individual DA.JS is supported by Cancer Research UK through the Cambridge Cancer Centre. NGB is supported by the NIHR Cambridge Biomedical Research Centre. VoxTox is funded by Cancer Research UK.This is the final published version. It was first available from the British Institute of Radiology at http://dx.doi.org/10.1259/bjr.2014034

    Recalculation of dose for each fraction of treatment on TomoTherapy.

    Get PDF
    OBJECTIVE: The VoxTox study, linking delivered dose to toxicity requires recalculation of typically 20-37 fractions per patient, for nearly 2000 patients. This requires a non-interactive interface permitting batch calculation with multiple computers. METHODS: Data are extracted from the TomoTherapy(®) archive and processed using the computational task-management system GANGA. Doses are calculated for each fraction of radiotherapy using the daily megavoltage (MV) CT images. The calculated dose cube is saved as a digital imaging and communications in medicine RTDOSE object, which can then be read by utilities that calculate dose-volume histograms or dose surface maps. The rectum is delineated on daily MV images using an implementation of the Chan-Vese algorithm. RESULTS: On a cluster of up to 117 central processing units, dose cubes for all fractions of 151 patients took 12 days to calculate. Outlining the rectum on all slices and fractions on 151 patients took 7 h. We also present results of the Hounsfield unit (HU) calibration of TomoTherapy MV images, measured over an 8-year period, showing that the HU calibration has become less variable over time, with no large changes observed after 2011. CONCLUSION: We have developed a system for automatic dose recalculation of TomoTherapy dose distributions. This does not tie up the clinically needed planning system but can be run on a cluster of independent machines, enabling recalculation of delivered dose without user intervention. ADVANCES IN KNOWLEDGE: The use of a task management system for automation of dose calculation and outlining enables work to be scaled up to the level required for large studies.JES is supported by Cancer Research UK through the Cambridge Cancer Centre. MR, AB and KH are supported by Cancer Research UK through the VoxTox Research Programme. NGB is supported by the NIHR Cambridge Biomedical Research Centre.This is the author accepted manuscript. The final version is available from British Institute of Radiology via http://dx.doi.org/10.1259/bjr.2015077

    Accumulated dose to the rectum, measured using dose-volume histograms and dose-surface maps, is different from planned dose in all patients treated with radiotherapy for prostate cancer.

    Get PDF
    OBJECTIVE: We sought to calculate accumulated dose (DA) to the rectum in patients treated with radiotherapy for prostate cancer. We were particularly interested in whether dose-surface maps (DSMs) provide additional information to dose-volume histograms (DVHs). METHODS: Manual rectal contours were obtained for kilovoltage and daily megavoltage CT scans for 10 participants from the VoxTox study (380 scans). Daily delivered dose recalculation was performed using a ray-tracing algorithm. Delivered DVHs were summated to create accumulated DVHs. The rectum was considered as a cylinder, cut and unfolded to produce daily delivered DSMs; these were summated to produce accumulated DSMs. RESULTS: Accumulated dose-volumes were different from planned in all participants. For one participant, all DA levels were higher and all volumes were larger than planned. For four participants, all DA levels were lower and all volumes were smaller than planned. For each of these four participants, ≥1% of pixels on the accumulated DSM received ≥5 Gy more than had been planned. CONCLUSION: Differences between accumulated and planned dose-volumes were seen in all participants. DSMs were able to identify differences between DA and planned dose that could not be appreciated from the DVHs. Further work is needed to extract the dose data embedded in the DSMs. These will be correlated with toxicity as part of the VoxTox Programme. ADVANCES IN KNOWLEDGE: DSMs are able to identify differences between DA and planned dose that cannot be appreciated from DVHs alone and should be incorporated into future studies investigating links between DA and toxicity.JES is supported by Cancer Research UK through the Cambridge Cancer Centre. NGB is supported by the NIHR Cambridge Biomedical Research Centre. KH, MR and AMB are supported by the VoxTox Research Programme, which is funded by Cancer Research UK.This is the final version of the article. It first appeared from the British Institute of Radiology via http://dx.doi.org/10.1259/bjr.2015024

    Using computing models from particle physics to investigate dose-toxicity correlations in cancer radiotherapy

    Get PDF
    © Published under licence by IOP Publishing Ltd. A system has been developed to provide flexible, efficient and robust processing of radiotherapy planning and treatment data collected in the VoxTox project, which investigates differences between planned and delivered dose, and dose-toxicity correlations. This paper outlines the system requirements and implementation, highlighting the use made of software tools and computing models developed for experiments at the Large Hadron Collider. Experience with VoxTox data processing is summarised

    Delivered dose can be a better predictor of rectal toxicity than planned dose in prostate radiotherapy

    Get PDF
    BACKGROUND AND PURPOSE\textbf{BACKGROUND AND PURPOSE}: For the first time, delivered dose to the rectum has been calculated and accumulated throughout the course of prostate radiotherapy using megavoltage computed tomography (MVCT) image guidance scans. Dosimetric parameters were linked with toxicity to test the hypothesis that delivered dose is a stronger predictor of toxicity than planned dose. MATERIAL AND METHODS\textbf{MATERIAL AND METHODS}: Dose-surface maps (DSMs) of the rectal wall were automatically generated from daily MVCT scans for 109 patients within the VoxTox research programme. Accumulated-DSMs, representing total delivered dose, and planned-DSMs, from planning CT data, were parametrised using Equivalent Uniform Dose (EUD) and 'DSM dose-width', the lateral dimension of an ellipse fitted to a discrete isodose cluster. Associations with 6 toxicity endpoints were assessed using receiver operator characteristic curve analysis. RESULTS\textbf{RESULTS}: For rectal bleeding, the area under the curve (AUC) was greater for accumulated dose than planned dose for DSM dose-widths up to 70Gy. Accumulated 65Gy DSM dose-width produced the strongest spatial correlation (AUC 0.664), while accumulated EUD generated the largest AUC overall (0.682). For proctitis, accumulated EUD was the only reportable predictor (AUC 0.673). Accumulated EUD was systematically lower than planned EUD. CONCLUSIONS\textbf{CONCLUSIONS}: Dosimetric parameters extracted from accumulated DSMs have demonstrated stronger correlations with rectal bleeding and proctitis, than planned DSMs.LEAS is supported by the University of Cambridge W D Armstrong Trust Fund; AMB, MRR and KH are supported by the VoxTox Programme Grant, which is funded by Cancer Research UK (CRUK); JES was supported by a CRUK Clinical Research Fellowship; DJN is supported by a CRUK Clinical Research Fellowship; NGB is Principle Investigator of the CRUK VoxTox Programme and is supported by the NIHR Cambridge Biomedical Research Centre

    Automatic contour propagation using deformable image registration to determine delivered dose to spinal cord in head-and-neck cancer radiotherapy.

    Get PDF
    To determine delivered dose to the spinal cord, a technique has been developed to propagate manual contours from kilovoltage computed-tomography (kVCT) scans for treatment planning to megavoltage computed-tomography (MVCT) guidance scans. The technique uses the Elastix software to perform intensity-based deformable image registration of each kVCT scan to the associated MVCT scans. The registration transform is then applied to contours of the spinal cord drawn manually on the kVCT scan, to obtain contour positions on the MVCT scans. Different registration strategies have been investigated, with performance evaluated by comparing the resulting auto-contours with manual contours, drawn by oncologists. The comparison metrics include the conformity index (CI), and the distance between centres (DBC). With optimised registration, auto-contours generally agree well with manual contours. Considering all 30 MVCT scans for each of three patients, the median CI is [Formula: see text], and the median DBC is ([Formula: see text]) mm. An intra-observer comparison for the same scans gives a median CI of [Formula: see text] and a DBC of ([Formula: see text]) mm. Good levels of conformity are also obtained when auto-contours are compared with manual contours from one observer for a single MVCT scan for each of 30 patients, and when they are compared with manual contours from six observers for two MVCT scans for each of three patients. Using the auto-contours to estimate organ position at treatment time, a preliminary study of 33 patients who underwent radiotherapy for head-and-neck cancers indicates good agreement between planned and delivered dose to the spinal cord.CRUK, Singapore Government, Addenbrooke's Charitable Trust, Cambridge Biomedical Research Centr

    Applying physical science techniques and CERN technology to an unsolved problem in radiation treatment for cancer: the multidisciplinary ‘VoxTox’ research programme

    Get PDF
    The VoxTox research programme has applied expertise from the physical sciences to the problem of radiotherapy toxicity, bringing together expertise from engineering, mathematics, high energy physics (including the Large Hadron Collider), medical physics and radiation oncology. In our initial cohort of 109 men treated with curative radiotherapy for prostate cancer, daily image guidance computed tomography (CT) scans have been used to calculate delivered dose to the rectum, as distinct from planned dose, using an automated approach. Clinical toxicity data have been collected, allowing us to address the hypothesis that delivered dose provides a better predictor of toxicity than planned dose.JES was supported by Cancer Research UK through the Cambridge Cancer Centre. NGB, ASP and MG are supported by the National Institute of Health Research Cambridge Biomedical Research Centre. KH, MR AMB, EW and SJB were supported by the VoxTox Research Programme, funded by Cancer Research UK. DJN is supported by Addenbrooke’s Charitable Trust and Cancer Research UK through the Cambridge Cancer Centre. FMB was supported by the Science and Technology Facilities Council. MPDS was part supported by the VoxTox Research Programme, funded by Cancer Research UK. RJ was part supported by the VoxTox Research Programme, funded by Cancer Research UK. LS is supported by the Armstrong Trust. XC was supported by the Isaac Newton Trust. CBS acknowledges support from the EPSRC Centre for Mathematical and Statistical Analysis of Multimodal Clinical Imaging, the Leverhulme Trust, the EU-RISE project CHiPS and the Cantab Capital Institute for the Mathematics of Information. NT was supported by a Gates-Cambridge Scholarship, funded by the Bill and Melinda Gates Foundation, PLY and SYKS by the Singapore Government
    • …
    corecore