203 research outputs found

    The evolution of hospice and palliative care in Ethiopia: From historic milestones to future directions

    Get PDF
    Abstract Introduction: This article reviews the genesis of hospice and palliative care in Ethiopia, examines recent progress, and makes recommendations for the way forward. Result:Although the delivery of palliative care in Ethiopia has shown significant progress over the past two decades, it remains patchy, with the interdisciplinary components of psychological, social and spiritual support lagging behind the primarily medical approach. Discusion: As a pillar of healthcare provision, and in conjunction with health promotion, disease prevention, curative services and rehabilitation, PC awareness and its development should be a high priority Conclusion: More research on the root causes of lack of integrated services for PC and genuine conversation is required [Ethiop. J. Health Dev. 2020; 34(4):310-312] Key words: Palliative care, Ethiopia, life-threatening chronic illness, hospice, end-of-life car

    Variation in the Diagnosis and Management of Appendicitis at Canadian Pediatric Hospitals

    Get PDF
    Objectives The objective was to characterize the variations in practice in the diagnosis and management of children admitted to hospitals from Canadian pediatric emergency departments (EDs) with suspected appendicitis, specifically the timing of surgical intervention, ED investigations, and management strategies. Methods Twelve sites participated in this retrospective health record review. Children aged 3 to 17 years admitted to the hospital with suspected appendicitis were eligible. Site-specific demographics, investigations, and interventions performed were recorded and compared. Factors associated with after-hours surgery were determined using generalized estimating equations logistic regression. Results Of the 619 children meeting eligibility criteria, surgical intervention was performed in 547 (88%). After-hours surgery occurred in 76 of the 547 children, with significant variation across sites (13.9%, 95% confidence interval = 7.1% to 21.6%, p \u3c 0.001). The overall perforation rate was 17.4% (95 of 547), and the negative appendectomy rate was 6.8% (37 of 547), varying across sites (p = 0.004 and p = 0.036, respectively). Use of inflammatory markers (p \u3c 0.001), blood cultures (p \u3c 0.001), ultrasound (p = 0.001), and computed tomography (p = 0.001) also varied by site. ED administration of narcotic analgesia and antibiotics varied across sites (p \u3c 0.001 and p = 0.001, respectively), as did the type of surgical approach (p \u3c 0.001). After-hours triage had a significant inverse association with after-hours surgery (p = 0.014). Conclusions Across Canadian pediatric EDs, there exists significant variation in the diagnosis and management of children with suspected appendicitis. These results indicate that the best diagnostic and management strategies remain unclear and support the need for future prospective, multicenter studies to identify strategies associated with optimal patient outcomes

    A Model of Tuberculosis Screening for Pregnant Women in Resource-Limited Settings Using Xpert MTB/RIF

    Get PDF
    Timely diagnosis and treatment of maternal tuberculosis (TB) is important to reduce morbidity and mortality for both the mother and child, particularly in women who are coinfected with HIV. The World Health Organization (WHO) recommends the integration of TB/HIV screening into antenatal services but available diagnostic tools are slow and insensitive, resulting in delays in treatment initiation. Recently the WHO endorsed Xpert MTB/RIF, a highly sensitive, real-time PCR assay for Mycobacterium tuberculosis that simultaneously detects rifampicin resistance directly from sputum and provides results within 100 minutes. We propose a model for same-day TB screening and diagnosis of all pregnant women at antenatal care using Xpert MTB/RIF. Pilot studies are urgently required to evaluate strategies for the integration of TB screening into antenatal clinics using new diagnostic technologies

    A Model of Tuberculosis Screening for Pregnant Women in Resource-Limited Settings Using Xpert MTB/RIF

    Get PDF
    Timely diagnosis and treatment of maternal tuberculosis (TB) is important to reduce morbidity and mortality for both the mother and child, particularly in women who are coinfected with HIV. The World Health Organization (WHO) recommends the integration of TB/HIV screening into antenatal services but available diagnostic tools are slow and insensitive, resulting in delays in treatment initiation. Recently the WHO endorsed Xpert MTB/RIF, a highly sensitive, real-time PCR assay for Mycobacterium tuberculosis that simultaneously detects rifampicin resistance directly from sputum and provides results within 100 minutes. We propose a model for same-day TB screening and diagnosis of all pregnant women at antenatal care using Xpert MTB/RIF. Pilot studies are urgently required to evaluate strategies for the integration of TB screening into antenatal clinics using new diagnostic technologies

    A model of tuberculosis screening for pregnant women in resource-limited settings using Xpert MTB/RIF

    Get PDF
    Timely diagnosis and treatment of maternal tuberculosis (TB) is important to reduce morbidity and mortality for both the mother and child, particularly in women who are coinfected with HIV. TheWorld Health Organization (WHO) recommends the integration of TB/HIV screening into antenatal services but available diagnostic tools are slow and insensitive, resulting in delays in treatment initiation. Recently the WHO endorsed Xpert MTB/RIF, a highly sensitive, real-time PCR assay for Mycobacterium tuberculosis that simultaneously detects rifampicin resistance directly from sputum and provides results within 100 minutes. We propose a model for same-day TB screening and diagnosis of all pregnant women at antenatal care using Xpert MTB/RIF. Pilot studies are urgently required to evaluate strategies for the integration of TB screening into antenatal clinics using new diagnostic technologies

    An Evaluation of the Performance and Acceptability of Three LED Fluorescent Microscopes in Zambia: Lessons Learnt for Scale-Up

    Get PDF
    The World Health Organization recommends the roll-out of light-emitting diode (LED) fluorescent microscopes (FM) as an alternative to light microscopes in resource-limited settings. We evaluated the acceptability and performance of three LED FMs after a short orientation among laboratory technicians from government health centers in Zambia. Sixteen technicians with varied light microscopy experience were oriented to FMs and divided into groups; each group read a different set of 40 slides on each LED FM (Primo Star iLED™, Lumin™, FluoLED™) and on a reference mercury-vapor FM (Olympus BX41TF). Slide reading times were recorded. An experienced FM technician examined each slide on the Olympus BX41TF. Sensitivity and specificity compared to TB culture were calculated. Misclassification compared to the experienced technician and inter-rater reliability between trainees was assessed. Trainees rated microscopes on technical aspects. Primo Star iLED™, FluoLED™ and Olympus BX41TF had comparable sensitivities (67%, 65% and 65% respectively), with the Lumin™ significantly worse (56%; p<0.05). Specificity was low for trainees on all microscopes (75.9%) compared to the experienced technician on Olympus BX41TF (100%). Primo Star iLED™ had significantly less misclassification (21.1% p<0.05) than FluoLED™ (26.5%) and Lumin™ (26.8%) and significantly higher inter-rater reliability (0.611; p<0.05), compared to FluoLED™ (0.523) and Lumin™ (0.492). Slide reading times for LED FMs were slower than the reference, but not significantly different from each other. Primo Star iLED™ rated highest in acceptability measures, followed by FluoLED™ then Lumin™. Primo Star iLED™ was consistently better than FluoLED™ and Lumin™, and performed comparably to the Olympus BX41TF in all analyses, except reading times. The Lumin™ compared least favorably and was thought unacceptable for use. Specificity and inter-rater reliability were low for all microscopes suggesting that a brief orientation was insufficient in this setting. These results provide important data for resource-limited settings to consider as they scale-up LED FMs
    corecore