68 research outputs found

    Glucose levels and hemodynamic changes in patients submitted to routine dental treatment with and without local anesthesia

    Get PDF
    OBJECTIVE: The aim of this study was to (1) observe the extent to which hemodynamic and glucose measurements change in patients submitted to a dental procedure with and without a local anesthetic and a vasoconstrictor (LAVA; 2% mepivacaine with adrenaline 1100,000) and (2) correlate those parameters with the patients' anxiety levels. METHOD: This was an unblinded, random, prospective, and observational study with paired groups. Patients were evaluated during two different consultations during which they either did or did not receive a local anesthetic/vasoconstrictor. RESULTS: Thirty-seven patients ranging in age from 18 to 45 years (mean 30.4 ± 5.5 years) were evaluated. Hemodynamic parameters, including systolic blood pressure, diastolic blood pressure, heart rate, and glucose levels, did not change significantly in healthy patients, regardless of whether a LAVA was administered during the dental treatment. CONCLUSION: The patients' anxiety statuses neither varied significantly nor showed any correlation with the studied hemodynamic parameters and glucose levels, regardless of whether local anesthetics were used

    Cross-cultural adaptation of the orthognathic quality of life questionnaire (OQLQ) in a Brazilian sample of patients with dentofacial deformities

    Get PDF
    Objectives: The aim of this study is to translate into Portuguese-Brazilian language and adapt cross-culturally to the Brazilian population the Orthognathic Quality of Life Questionnaire (OQLQ). Study Design: The cross-cultural adaptation process followed six stages which are; (I) initial translation, (II) synthesis of the translation, (III) back translation, (IV) expert committee and (V) test of the prefinal version. For validation process, the OQLQ results were compared with Oral Health Impact Profile Questionnaire (OHIP-49), with the generic SF-36 Quality of Life Questionnaire and a visual analogue scale. A convenience sample of 25 patients was selected in two Southern Brazilian states of Santa Catarina and Rio Grande do Sul. Results: Internal consistency analysis of the OQLQ-Brazilian showed good correlation for items or domains and the test-retest reliability also presented excellent intra-class correlation coefficients. OQLQ-Brazilian exhibited a weak and negative correlation with SF-36, and good correlation with OHIP-49. Conclusion: The OQLQ-Brazilian preserved and reached equivalence with its original source and the findings also corroborate that there is good evidence for the construct validity. The demonstration of its reproducibility, reliability and validity makes this instrument an additional useful parameter for evaluation of the impact of dentofacial deformity over the quality of life for Brazilians. © Medicina Oral

    Mucocele em lábio inferior – Relato de caso clínico

    Get PDF
    Mucocele é a terminologia usada para designar a manifestação clínica de fenômenos que podem afetar as glândulas salivares, sendo eles o estravasamento de muco e o cisto de retenção mucoso. Clinicamente, possuem características clínicas idênticas, porém distintas quando analisadas sob exame histopatológico. Entretanto, sob ponto de vista de prognóstico e de tratamento, a literatura não aponta diferença entre as lesões, sendo a enucleação o tratamento mais comum e usual para o mucocele. A etiologia dessa patologia está relacionada com traumatismo, rompimento ou obstrução do ducto secretor de uma glândula salivar, acomulando a secreção a ser acumulada no próprio ducto da glândula ou nos tecidos superficiais adjacentes. Os autores apresentam um caso clínico de mucocele em lábio inferior e discutem a etiopatogenia e as características clínicas que levaram ao diagnóstico clínico da lesão, assim como seu prognóstico e tratamento. Os autores concluem a eficácia e a resolutividade da técnica cirúrgica de enucleação no relato apresentado.    Palavras-chave: Mucocele. Cisto de retenção mucoso. Fenômeno de extravasamento de muco

    Desequilíbrios musculares entre flexores dorsais e plantares do tornozelo após tratamento conservador e acelerado da ruptura do tendão calcâneo

    Get PDF
    Achilles tendon rupture reduces ankle plantarflexor (PF) muscles mechanical overload. This change in the ankle joint mechanics changes the natural muscle balance between dorsiflexor (DF) and PF muscles. The purpose of this study was to assess such imbalance by concentric conventional isokinetic torque ratios of patients who underwent different rehabilitation protocols after surgical repair of the Achilles tendon. After surgery, subjects were assigned to either a conservative or to an accelerated rehabilitation group. The conservative group (11 men, 41.3±7.9 years old) remained with a plaster cast for 6 weeks after surgery. The accelerated group (13 men, 43.5±13,7 years old) used a"robofoot" cast for 2 weeks and underwent ankle mobilization and early weight bearing for a period of 6 weeks post-immobilization. At 3 months post-surgery the ratio between the maximal concentric DF torque and the maximal concentric PF torque was evaluated with an isokinetic dynamometer. Torque ratios on the surgery side were higher (pA ruptura do tendão calcâneo (TC) reduz a sobrecarga mecânica dos flexores plantares (FP) do tornozelo. Essa alteração muda o equilíbrio natural entre os FP e flexores dorsais (FD) do tornozelo. O objetivo do estudo foi avaliar as razões isocinéticas concêntricas convencionais de torque de pacientes submetidos a tratamento cirúrgico de ruptura aguda do TC após dois protocolos diferentes de reabilitação. Após procedimento cirúrgico para reconstrução do TC, a amostra foi dividida de forma intencional em dois grupos: conservador (GC, 11 homens, 41,3±7,9 anos) e grupo acelerado (GA, 13 homens, 43,5±13,7 anos). O GC permaneceu com imobilização gessada no tornozelo por seis semanas (tratamento tradicional), enquanto o GA usou uma órtese robofoot em posição neutra e, após duas semanas, iniciou mobilização e apoio precoce do tornozelo, com reabilitação por seis semanas. Após 3 meses de pós-operatório, a razão do torque concêntrico máximo dos FD pelos FP do tornozelo foi avaliada por dinamômetro isocinético. As razões de torque do lado operado se mantiveram superiores às do lado saudável mesmo após 3 meses de pós-operatório (

    Determinação dos parâmetros do circuito equivalente de um motor de indução trifásico a partir dos dados de ensaio com carga

    Get PDF
    This paper aims to determine the parameters of the equivalent circuit of a three-phase induction motor based on load test data. These parameters are considered concentrated and include resistances and reactances associated with the machine's operating frequency. Utilizing data from the load test, a new methodology adopts heuristics to narrow down the search range for each parameter through optimization. The obtained values are subsequently compared with results obtained using the classical methodology. Finally, with the parameters in hand, results for line current, output power, and efficiency, all as functions of the motor's operating speed, are presented using the equivalent circuit. This provides a comprehensive view of the motor's performance under real operating conditions and validates the parameters obtained with the proposed new methodology. This provides a comprehensive insight into the motor's performance under real operating conditions and validates the obtained parameters using the new methodology.Este artigo busca determinar os parâmetros do circuito equivalente de um motor de indução trifásico a partir dos dados de ensaio com carga. Tais parâmetros são ditos concentrados e compreendem de resistências e reatâncias associadas à frequência de operação da máquina. Utilizando dados provenientes do ensaio com carga, uma nova metodologia adota heurísticas para restringir o intervalo de busca de cada parâmetro por meio de otimização. Os valores obtidos são posteriormente comparados com os resultados obtidos pela metodologia clássica. Por fim, de posse dos parâmetros, resultados para a corrente de linha, potência de saída e rendimento, todos em função da velocidade de operação do motor, são apresentados a partir do uso do circuito equivalente, o que possibilita uma visão abrangente do desempenho do motor em condições reais de operação e valida os parâmetros obtidos com a nova metodologia proposta

    W/B Planner -Solucionador para Roteamento de Veículos no Transporte Fretado de Passageiros

    Get PDF
    Companies of chartered transport of passengers need to manage routes with boarding points, based on the location of the passengers. As the number of routes grow, the task of manually manage and optimize routings becomes inviable. The vehicle routing problem characterizes inside this scenario, branching into specific problems, that need different solutions for each case. Meta-heuristics are usually used to build solver algorithms for these problems. Constraint programming was chosen for helping build the solver. The main objective of the work was, to develop a system performing the solution of routings in an automatized way, by utilization of constraint programming and meta-heuristic algorithms. To minimize transport costs, travel time, and maximize the use of vehicles in an efficient and planned manner. The tests were carried out in conjunction with a routing administrator, to validate the use of the application within the research field. From the evaluations made, they demonstrated the utility of the software within its purpose. Of which it was observed that the product of this research, helped in the construction of an automated fleet consulting tool, being able to dynamically point out the distribution and operationality of a fleet of chartered vehicles in the transportation of passengers

    Tratamento conservador em tipos diferentes de tumores odontogênicos: relatos de caso / Conservative treatment in different types of odontogenic tumors: case reports

    Get PDF
    Os tumores ósseos odontogênicos e maxilofaciais incluem um grupo heterogêneo de lesões que variam de neoplasias benignas a malignas. O ameloblastoma é um tumor odontogênico benigno de origem epitelial, e representa a entidade mais comum desse grupo de lesões depois dos odontomas. Embora benigno é considerado agressivo, devido a capacidade de infiltração local e altas taxas de recidiva registradas. De diferente etiologia o mixoma odontogênico é uma neoplasia benigna rara de origem mesenquimal que afeta os ossos gnáticos, representando cerca de 5% dos tumores odontogênicos. Os tumores se apresentam radiograficamente como lesões radiolúcidas, uni ou multiloculares, com margens que variam de bem definidas à difusas. Clinicamente, a expansão óssea cortical e o deslocamento dentário são frequentemente observados. As metodologias propostas variam da tradicional cirurgia radical, a cirurgia conservadora e, recentemente terapias medicamentosas direcionadas especificamente as vias de sinalização envolvidas na patogênese tumoral. Cada metodologia apresenta vantagens e desvantagens, no entanto, tem sido observado uma tendência da literatura atual a utilizar métodos mais conservadores, associados a um acompanhamento periódico e a longo prazo. O objetivo do presente trabalho é relatar dois casos de um extenso ameloblastoma convencional em uma paciente jovem, e um mixoma odontogênico, tratado de maneira conservadora, e que tem demonstrado inicialmente um resultado adequado. Conclui-se que métodos alternativos e conservadores vem ganhando espaço no tratamento dessa patologia, os quais vem demonstrando resultados satisfatórios

    Mandíbulas Edêntulas severamente reabsorvidas tratadas com implantes curtos – apresentação de 4 casos clínicos e controle de 30 a 36 meses

    Get PDF
    As atrofias severas da mandíbula apresentam grande dificuldade de tratamento, seja através de próteses convencionais, seja por próteses implanto-suportadas. Várias técnicas são descritas para o aumento vertical do rebordo ósseo. Todas apresentam alta morbidade, dificuldade técnica e prognóstico duvidoso. Os implantes curtos apresentam uma solução mais simples, menos mórbida e atualmente apresentam prognóstico semelhante aos de tamanho convencional. O objetivo deste trabalho é apresentar 4 casos consecutivos de mandíbulas severamente reabsorvidas e tratadas com implantes de 7,5 a 10mm de comprimento e próteses tipo protocolo. Neste casos foram instalados 12 implantes sendo que apenas um não apresentou sucesso sendo substituído por outro implante instalado em carga imediata. Estes casos foram acompanhados por 30 a 36 meses não havendo nenhuma perda de implante após a instalação das próteses e havendo uma perda óssea perimplantar média de 0,71mm. Os casos apresentados mostram que o tratamento com 4 implantes de tamanho reduzido retendo prótese tipo protocolo são uma boa opção para o tratamento das mandíbuals atróficas

    DISTRAÇÃO OSTEOGÊNICA ANTERO-POSTERIOR DA MAXILA PARA PERMITIR REABILITAÇÃO COM IMPLANTES

    Get PDF
    O tratamento da maxila atrófica edêntula é dos mais desafiadores na implantodontia principalmente quando esta está retroposicionada em relação a mandíbula. Nestas situações em que o paciente é portador de relação dos rebordos de classe III a reabsorção óssea causada pela perda dos dentes aumenta a discrepância dificultando o tratamento. O reposicionamento anteroposterior da maxila pode ser realizado através de compensações protéticas de grande proporção, cirurgias ortognáticas e distrações osteogênicas. A ausência dos incisivos centrais dificulta o posicinamento das osteotomias provocando erros verticais e horizontais. Estes erros podem ser minimizados através da distração osteogênica. Os autores descrevem um caso tratado com distração osteogênica para avanças a maxila e posteriormente reabilitar a maxila com implantes osseointegrados
    corecore