30 research outputs found

    Pediatric interventional radiography equipment: safety considerations

    Get PDF
    This paper discusses pediatric image quality and radiation dose considerations in state-of-the-art fluoroscopic imaging equipment. Although most fluoroscopes are capable of automatically providing good image quality on infants, toddlers, and small children, excessive radiation dose levels can result from design deficiencies of the imaging device or inappropriate configuration of the equipment’s capabilities when imaging small body parts. Important design features and setup choices at installation and during the clinical use of the imaging device can improve image quality and reduce radiation exposure levels in pediatric patients. Pediatric radiologists and cardiologists, with the help of medical physicists, need to understand the issues involved in creating good image quality at reasonable pediatric patient doses. The control of radiographic technique factors by the generator of the imaging device must provide a large dynamic range of mAs values per exposure pulse during both fluoroscopy and image recording as a function of patient girth, which is the thickness of the patient in the posterior–anterior projection at the umbilicus (less than 10 cm to greater than 30 cm). The range of pulse widths must be limited to less than 10 ms in children to properly freeze patient motion. Variable rate pulsed fluoroscopy can be leveraged to reduce radiation dose to the patient and improve image quality. Three focal spots with nominal sizes of 0.3 mm to 1 mm are necessary on the pediatric unit. A second, lateral imaging plane might be necessary because of the child’s limited tolerance of contrast medium. Spectral and spatial beam shaping can improve image quality while reducing the radiation dose. Finally, the level of entrance exposure to the image receptor of the fluoroscope as a function of operator choices, of added filter thickness, of selected pulse rate, of the selected field-of-view and of the patient girth all must be addressed at installation

    Transient Tachypnoea of the Newborn

    No full text

    Menkes disease

    No full text

    Tuberous Sclerosis Associated With Pachygyria - Ct Findings

    No full text
    WOS: A1993MB28500025PubMed ID: 8255663The case is presented of a 1.5-year-old with the typical CT features of tuberous sclerosis and pachygyria, in combination. Tuberous sclerosis was evidenced by multiple subependymal calcifications, and pachygyria by the relevant CT appearances. Periventricular heterotopia and total callosal agenesis were associated findings. The findings in this patient convincingly suggest a close relationship between tuberous sclerosis and pachygyria, although the case is the first to be reported in the literature
    corecore