2 research outputs found

    Headspace solid-phase microextraction for the determination of benzene, toluene, ethylbenzene and xylenes in urine

    No full text
    A method for the determination of benzene, toluene, ethylbenzene and xylenes (BTEX) in urine of people exposed to these airborne pollutants present in the living environment, has been described. Solid-phase microextraction has been used for sampling BTEX from the headspace of urine and gas chromatography-mass spectrometry has been applied for the selective analysis of chemicals. The method has the following features: small volume of urine (2 ml) needed, linearity in the range of interest (from the limit of detection up to 5000 ng/l) with coefficient of correlation > or =0.998, limit of detection in the range 12-34 ng/l, good repeatability (coefficient of variation 2-7%), high specificity. The stability of the urine sample during storage (-20 degrees C) was evaluated: BTEX remained stable for up to 2 months. The assay has been successfully applied to the biological monitoring of two subjects environmentally exposed to airborne BTEX in an urban area

    Comparison between blood and urinary toluene as biomarkers of exposure to toluene

    No full text
    Objectives: To compare blood toluene (TOL-B) and urinary toluene (TOL-U) as biomarkers of occupational exposure to toluene, and to set a suitable procedure for collection and handling of specimens. Method: An assay based on headspace solid-phase microextraction (SPME) was used both for the determination of toluene urine/air partition coefficient (lambda(urine/air)) and for the biological monitoring of exposure to toluene in 31 workers (group A) and in 116 non-occupationally exposed subjects (group B). Environmental toluene (TOL-A) was sampled during the work shift (group A) or during the 24 h before specimen collection (group B. Blood and urine specimens were collected at the end of the shift (group A) or in the morning (group B) and toluene was measured. Results: Toluene lambda(urine/air) was 3.3 +/- 0.9. Based on the specimen/air partition coefficient, it was calculated that the vial in which the sample is collected had to be filled up to 85% of its volume with urine and 50% with blood in order to limit the loss of toluene in the air above the specimen to less than 5%. Environmental and biological monitoring of workers showed that the median personal exposure to toluene (TOL-A) during the work-shift was 80 mg/m(3), the corresponding TOL-B was 82 mu g/l and TOL-U was 13 mu g/l Personal exposure to toluene in environmentally exposed subjects was 0.05 mg/m(3), TOL-B was 0.36 mu g/l and TOL-U was 0.20 mu g/l. A significant correlation (P < 0.05) was observed between TOL-B or TOL-U and TOL-A (Pearson's r = 0.782 and 0.754) in workers, but not in controls. A significant correlation was found between TOL-U and TOL-B both in workers and in controls (r = 0.845 and 0.681). Conclusion: The comparative evaluation of TOL-B and TOL-U showed that they can be considered to be equivalent biomarkers as regards their capacity to distinguish workers and controls and to correlate with exposure. However, considering that TOL-U does not require an invasive specimen collection, it appears to be a more convenient tool for the biological monitoring of exposure to toluene
    corecore