Detection of Extracochlear Electrodes in Cochlear Implants with Electric Field Imaging/Transimpedance Measurements: A Human Cadaver Study.
OBJECTIVES: Extracochlear electrodes in cochlear implants (CI), defined as individual electrodes on the electrode array located outside of the cochlea, are not a rare phenomenon. The presence of extracochlear electrodes frequently goes unnoticed and could result in them being assigned stimulation frequencies that are either not delivered to, or stimulating neurons that overlap with intracochlear electrodes, potentially reducing performance. The current gold-standard for detection of extracochlear electrodes is computed tomography (CT), which is time-intensive, costly and involves radiation. It is hypothesized that a collection of Stimulation-Current-Induced Non-Stimulating Electrode Voltage recordings (SCINSEVs), commonly referred to as "transimpedance measurements (TIMs)" or electric field imaging (EFI), could be utilized to detect extracochlear electrodes even when contact impedances are low. An automated analysis tool is introduced for detection and quantification of extracochlear electrodes. DESIGN: Eight fresh-frozen human cadaveric heads were implanted with the Advanced Bionics HiRes90K with a HiFocus 1J lateral-wall electrode. The cochlea was flushed with 1.0% saline through the lateral semicircular canal. Contact impedances and SCINSEVs were recorded for complete insertion and for 1 to 5 extracochlear electrodes. Measured conditions included: air in the middle ear (to simulate electrodes situated in the middle ear), 1.0% saline in the middle ear (to simulate intraoperative conditions with saline or blood in the middle ear), and soft tissue (temporal muscle) wrapped around the extracochlear electrodes (to simulate postoperative soft-tissue encapsulation of the electrodes). Intraoperative SCINSEVs from patients were collected, for clinical purposes during slow insertion of the electrode array, as well as from a patient postoperatively with known extracochlear electrodes. RESULTS: Full insertion of the cochlear implant in the fresh-frozen human cadaveric heads with a flushed cochlea resulted in contact impedances in the range of 6.06 ± 2.99 kΩ (mean ± 2SD). Contact impedances were high when the extracochlear electrodes were located in air, but remained similar to intracochlear contact impedances when in saline or soft tissue. SCINSEVs showed a change in shape for the extracochlear electrodes in air, saline, and soft tissue. The automated analysis tool showed a specificity and sensitivity of 100% for detection of two or more extracochlear electrodes in saline and soft tissue. The quantification of two or more extracochlear electrodes was correct for 84% and 81% of the saline and soft tissue measurements, respectively. CONCLUSIONS: Our analysis of SCINSEVs (specifically the EFIs from this manufacturer) shows good potential as a detection tool for extracochlear electrodes, even when contact impedances remain similar to intracochlear values. SCINSEVs could potentially replace CT in the initial screening for extracochlear electrodes. Detecting migration of the electrode array during the final stages of surgery could potentially prevent re-insertion surgery for some CI users. The automated detection tool could assist in detection and quantification of two or more extracochlear electrodes
Terrestrial mammals of a sheep-grazing property on Bruny Island, Tasmania
Land-based mammals were surveyed in a mosaic of dry sclerophyll forests and pasture on a sheep-grazing property on Bruny Island, Tasmania, using a range of methods in August 2010. 'This is the first mammal survey of a sheep-grazing property in Tasmania and the first large-scale survey of mammals on Bruny Island. Ten species were recorded comprising seven native and three introduced species. The Little Forest Bat, Vespadelus vulturnus, and the Black Rat, Rattus rattus, were recorded for the first time on Bruny Island, although both are probably long-term residents. No mammal species listed as rare or threatened under Tasmanian or Australian legislation were found on the property. Large numbers of Eastern Quolls, Dasyurus viverrinus, Brushtail Possums, Trichosurus vulpecula, Tasmanian Pademelons, Thylogale billardierii, and Bennetts Wallabies, Macropus rufogriseus, were recorded in a range of dry sclerophyll forests and in pasture. Longnosed Potoroos, Potorous tridactylus, were recorded widely on the property in native vegetation with relatively thick ground cover. Eastern Quoll capture rates were highest in pasture areas and in Eucalyptus ovata forest. Brushtail Possums, Long-nosed Potoroos, Tasmanian Pademelons and Bennetts Wallabies were virtually unrecorded from E. tenuiramis forest and woodlands. Given the level of survey effort and their potential to occur on the property it was remarkable that no Tasmanian Bettong, Bettongia gaimardi, Eastern Barred Bandicoot, Perameles gunnii, Southern Brown Bandicoot, lsoodon obesulus, or introduced House Mouse, Mus musculus, were recorded. We found that camera trapping was more cost-efficient than cage trapping for detecting the presence of mammals on "Murrayfield". Recommendations for ongoing management and monitoring of mammals are provided
Recommended from our members
Intraoperative Monitoring of the Cochlear Nerve during Neurofibromatosis Type-2 Vestibular Schwannoma Surgery and Description of a "Test Intracochlear Electrode".
Objectives A decision on whether to insert a cochlear implant can be made in neurofibromatosis 2 (NF2) if there is objective evidence of cochlear nerve (CN) function post vestibular schwannoma (VS) excision. We aimed to develop intraoperative CN monitoring to help in this decision. Design We describe the intraoperative monitoring of a patient with NF2 and our stimulating and recording set up. A novel test electrode is used to stimulate the CN electrically. Setting This study was set at a tertiary referral center for skull base pathology. Main outcome measure Preserved auditory brainstem responses leading to cochlear implantation. Results Electrical auditory brainstem response (EABR) waveforms will be displayed from different stages of the operation. A cochlear implant was inserted at the same sitting based on the EABR. Conclusion Electrically evoked CN monitoring can provide objective evidence of CN function after VS excision and aid in the decision-making process of hearing rehabilitation in patients who will be rendered deaf
Combination of Spectral and Binaurally Created Harmonics in a Common Central Pitch Processor
A fundamental attribute of human hearing is the ability to extract a residue pitch from harmonic complex sounds such as those produced by musical instruments and the human voice. However, the neural mechanisms that underlie this processing are unclear, as are the locations of these mechanisms in the auditory pathway. The ability to extract a residue pitch corresponding to the fundamental frequency from individual harmonics, even when the fundamental component is absent, has been demonstrated separately for conventional pitches and for Huggins pitch (HP), a stimulus without monaural pitch information. HP is created by presenting the same wideband noise to both ears, except for a narrowband frequency region where the noise is decorrelated across the two ears. The present study investigated whether residue pitch can be derived by combining a component derived solely from binaural interaction (HP) with a spectral component for which no binaural processing is required. Fifteen listeners indicated which of two sequentially presented sounds was higher in pitch. Each sound consisted of two “harmonics,” which independently could be either a spectral or a HP component. Component frequencies were chosen such that the relative pitch judgement revealed whether a residue pitch was heard or not. The results showed that listeners were equally likely to perceive a residue pitch when one component was dichotic and the other was spectral as when the components were both spectral or both dichotic. This suggests that there exists a single mechanism for the derivation of residue pitch from binaurally created components and from spectral components, and that this mechanism operates at or after the level of the dorsal nucleus of the lateral lemniscus (brainstem) or the inferior colliculus (midbrain), which receive inputs from the medial superior olive where temporal information from the two ears is first combined
Recommended from our members
Using Interleaved Stimulation to Measure the Size and Selectivity of the Sustained Phase-Locked Neural Response to Cochlear Implant Stimulation
Abstract: We measured the sustained neural response to electrical stimulation by a cochlear implant (CI). To do so, we interleaved two stimuli with frequencies F1 and F2 Hz and recorded a neural distortion response (NDR) at F2-F1 Hz. We show that, because any one time point contains only the F1 or F2 stimulus, the instantaneous nonlinearities typical of electrical artefact should not produce distortion at this frequency. However, if the stimulus is smoothed, such as by charge integration at the nerve membrane, subsequent (neural) nonlinearities can produce a component at F2-F1 Hz. We stimulated a single CI electrode with interleaved sinusoids or interleaved amplitude-modulated pulse trains such that F2 = 1.5F1, and found no evidence for an NDR when F2-F1 was between 90 and 120 Hz. However, interleaved amplitude-modulated pulse trains with F2-F1~40 Hz revealed a substantial NDR with a group delay of about 45 ms, consistent with a thalamic and/or cortical response. The NDR could be measured even from recording electrodes adjacent to the implant and at the highest pulse rates (> 4000 pps) used clinically. We then measured the selectivity of this sustained response by presenting F1 and F2 to different electrodes and at different between-electrode distances. This revealed a broad tuning that, we argue, reflects the overlap between the excitation elicited by the two electrodes. Our results also provide a glimpse of the neural nonlinearity in the auditory system, unaffected by the biomechanical cochlear nonlinearities that accompany acoustic stimulation. Several potential clinical applications of our findings are discussed
Recommended from our members
Using Interleaved Stimulation to Measure the Size and Selectivity of the Sustained Phase-Locked Neural Response to Cochlear Implant Stimulation
Abstract: We measured the sustained neural response to electrical stimulation by a cochlear implant (CI). To do so, we interleaved two stimuli with frequencies F1 and F2 Hz and recorded a neural distortion response (NDR) at F2-F1 Hz. We show that, because any one time point contains only the F1 or F2 stimulus, the instantaneous nonlinearities typical of electrical artefact should not produce distortion at this frequency. However, if the stimulus is smoothed, such as by charge integration at the nerve membrane, subsequent (neural) nonlinearities can produce a component at F2-F1 Hz. We stimulated a single CI electrode with interleaved sinusoids or interleaved amplitude-modulated pulse trains such that F2 = 1.5F1, and found no evidence for an NDR when F2-F1 was between 90 and 120 Hz. However, interleaved amplitude-modulated pulse trains with F2-F1~40 Hz revealed a substantial NDR with a group delay of about 45 ms, consistent with a thalamic and/or cortical response. The NDR could be measured even from recording electrodes adjacent to the implant and at the highest pulse rates (> 4000 pps) used clinically. We then measured the selectivity of this sustained response by presenting F1 and F2 to different electrodes and at different between-electrode distances. This revealed a broad tuning that, we argue, reflects the overlap between the excitation elicited by the two electrodes. Our results also provide a glimpse of the neural nonlinearity in the auditory system, unaffected by the biomechanical cochlear nonlinearities that accompany acoustic stimulation. Several potential clinical applications of our findings are discussed
Pitch Comparisons between Electrical Stimulation of a Cochlear Implant and Acoustic Stimuli Presented to a Normal-hearing Contralateral Ear
Four cochlear implant users, having normal hearing in the unimplanted ear, compared the pitches of electrical and acoustic stimuli presented to the two ears. Comparisons were between 1,031-pps pulse trains and pure tones or between 12 and 25-pps electric pulse trains and bandpass-filtered acoustic pulse trains of the same rate. Three methods—pitch adjustment, constant stimuli, and interleaved adaptive procedures—were used. For all methods, we showed that the results can be strongly influenced by non-sensory biases arising from the range of acoustic stimuli presented, and proposed a series of checks that should be made to alert the experimenter to those biases. We then showed that the results of comparisons that survived these checks do not deviate consistently from the predictions of a widely-used cochlear frequency-to-place formula or of a computational cochlear model. We also demonstrate that substantial range effects occur with other widely used experimental methods, even for normal-hearing listeners
Understanding Pitch Perception as a Hierarchical Process with Top-Down Modulation
Pitch is one of the most important features of natural sounds, underlying the perception of melody in music and prosody in speech. However, the temporal dynamics of pitch processing are still poorly understood. Previous studies suggest that the auditory system uses a wide range of time scales to integrate pitch-related information and that the effective integration time is both task- and stimulus-dependent. None of the existing models of pitch processing can account for such task- and stimulus-dependent variations in processing time scales. This study presents an idealized neurocomputational model, which provides a unified account of the multiple time scales observed in pitch perception. The model is evaluated using a range of perceptual studies, which have not previously been accounted for by a single model, and new results from a neurophysiological experiment. In contrast to other approaches, the current model contains a hierarchy of integration stages and uses feedback to adapt the effective time scales of processing at each stage in response to changes in the input stimulus. The model has features in common with a hierarchical generative process and suggests a key role for efferent connections from central to sub-cortical areas in controlling the temporal dynamics of pitch processing
Across-Channel Timing Differences as a Potential Code for the Frequency of Pure Tones
When a pure tone or low-numbered harmonic is presented to a listener, the resulting travelling wave in the cochlea slows down at the portion of the basilar membrane (BM) tuned to the input frequency due to the filtering properties of the BM. This slowing is reflected in the phase of the response of neurons across the auditory nerve (AN) array. It has been suggested that the auditory system exploits these across-channel timing differences to encode the pitch of both pure tones and resolved harmonics in complex tones. Here, we report a quantitative analysis of previously published data on the response of guinea pig AN fibres, of a range of characteristic frequencies, to pure tones of different frequencies and levels. We conclude that although the use of across-channel timing cues provides an a priori attractive and plausible means of encoding pitch, many of the most obvious metrics for using that cue produce pitch estimates that are strongly influenced by the overall level and therefore are unlikely to provide a straightforward means for encoding the pitch of pure tones
Higher Sensitivity of Human Auditory Nerve Fibers to Positive Electrical Currents
Most contemporary cochlear implants (CIs) stimulate the auditory nerve with trains of amplitude-modulated, symmetric biphasic pulses. Although both polarities of a pulse can depolarize the nerve fibers and generate action potentials, it remains unknown which of the two (positive or negative) phases has the stronger effect. Understanding the effects of pulse polarity will help to optimize the stimulation protocols and to deliver the most relevant information to the implant listeners. Animal experiments have shown that cathodic (negative) current flows are more effective than anodic (positive) ones in eliciting neural responses, and this finding has motivated the development of novel speech-processing algorithms. In this study, we show electrophysiologically and psychophysically that the human auditory system exhibits the opposite pattern, being more sensitive to anodic stimulation. We measured electrically evoked compound action potentials in CI listeners for phase-separated pulses, allowing us to tease out the responses to each of the two opposite-polarity phases. At an equal stimulus level, the anodic phase yielded the larger response. Furthermore, a measure of psychophysical masking patterns revealed that this polarity difference was still present at higher levels of the auditory system and was therefore not solely due to antidromic propagation of the neural response. This finding may relate to a particular orientation of the nerve fibers relative to the electrode or to a substantial degeneration and demyelination of the peripheral processes. Potential applications to improve CI speech-processing strategies are discussed
- …