32 research outputs found
Pushing the high count rate limits of scintillation detectors for challenging neutron-capture experiments
One of the critical aspects for the accurate determination of neutron capture
cross sections when combining time-of-flight and total energy detector
techniques is the characterization and control of systematic uncertainties
associated to the measuring devices. In this work we explore the most
conspicuous effects associated to harsh count rate conditions: dead-time and
pile-up effects. Both effects, when not properly treated, can lead to large
systematic uncertainties and bias in the determination of neutron cross
sections. In the majority of neutron capture measurements carried out at the
CERN n\_TOF facility, the detectors of choice are the CD
liquid-based either in form of large-volume cells or recently commissioned sTED
detector array, consisting of much smaller-volume modules. To account for the
aforementioned effects, we introduce a Monte Carlo model for these detectors
mimicking harsh count rate conditions similar to those happening at the CERN
n\_TOF 20~m fligth path vertical measuring station. The model parameters are
extracted by comparison with the experimental data taken at the same facility
during 2022 experimental campaign. We propose a novel methodology to consider
both, dead-time and pile-up effects simultaneously for these fast detectors and
check the applicability to experimental data from Au(,),
including the saturated 4.9~eV resonance which is an important component of
normalization for neutron cross section measurements
Advances and new ideas for neutron-capture astrophysics experiments at CERN n_TOF
This article presents a few selected developments and future ideas related to the measurement of (n,Îł) data of astrophysical interest at CERN n_TOF. The MC-aided analysis methodology for the use of low-efficiency radiation detectors in time-of-flight neutron-capture measurements is discussed, with particular emphasis on the systematic accuracy. Several recent instrumental advances are also presented, such as the development of total-energy detectors with Îł-ray imaging capability for background suppression, and the development of an array of small-volume organic scintillators aimed at exploiting the high instantaneous neutron-flux of EAR2. Finally, astrophysics prospects related to the intermediate i neutron-capture process of nucleosynthesis are discussed in the context of the new NEAR activation area
Advances and new ideas for neutron-capture astrophysics experiments at CERN n_TOF
This article presents a few selected developments and future ideas related to the measurement of (n,Îł) data of astrophysical interest at CERN n_TOF. The MC-aided analysis methodology for the use of low-efficiency radiation detectors in time-of-flight neutron-capture measurements is discussed, with particular emphasis on the systematic accuracy. Several recent instrumental advances are also presented, such as the development of total-energy detectors with Îł-ray imaging capability for background suppression, and the development of an array of small-volume organic scintillators aimed at exploiting the high instantaneous neutron-flux of EAR2. Finally, astrophysics prospects related to the intermediate i neutron-capture process of nucleosynthesis are discussed in the context of the new NEAR activation area
Measurement and analysis of 155,157Gd(n,Îł) from thermal energy to 1 keV
We have measured the capture cross section of the 155Gd and 157Gd isotopes between 0.025 eV and 1 keV. The capture events were recorded by an array of 4 C6D6 detectors, and the capture yield was deduced exploiting the total energy detection system in combination with the Pulse Height Weighting Techniques. Because of the large cross section around thermal neutron energy, 4 metallic samples of different thickness were used to prevent problems related to self-shielding. The samples were isotopically enriched, with a cross contamination of the other isotope of less than 1.14%. The capture yield was analyzed with an R-Matrix code to describe the cross section in terms of resonance parameters. Near thermal energies, the results are significantly different from evaluations and from previous time-of-flight experiments. The data from the present measurement at n_TOF are publicly available in the experimental nuclear reaction database EXFOR
Measurement and analysis of
We have measured the capture cross section of the 155Gd and 157Gd isotopes between 0.025 eV and 1 keV. The capture events were recorded by an array of 4 C6D6 detectors, and the capture yield was deduced exploiting the total energy detection system in combination with the Pulse Height Weighting Techniques. Because of the large cross section around thermal neutron energy, 4 metallic samples of different thickness were used to prevent problems related to self-shielding. The samples were isotopically enriched, with a cross contamination of the other isotope of less than 1.14%. The capture yield was analyzed with an R-Matrix code to describe the cross section in terms of resonance parameters. Near thermal energies, the results are significantly different from evaluations and from previous time-of-flight experiments. The data from the present measurement at n_TOF are publicly available in the experimental nuclear reaction database EXFOR
New detection systems for an enhanced sensitivity in key stellar (n,Îł) measurements
Neutron capture cross-section measurements are fundamental in the study of astrophysical phenomena, such as the slow neutron capture (s-) process of nucleosynthesis operating in red-giant and massive stars. However, neutron capture measurements via the time-of-flight (TOF) technique on key s-process nuclei are often challenging. Difficulties arise from the limited mass (âŒmg) available and the high sample-related background in the case of the unstable s-process branching points. Measurements on neutron magic nuclei, that act as s-process bottlenecks, are affected by low (n,Îł) cross sections and a dominant neutron scattering background. Overcoming these experimental challenges requires the combination of facilities with high instantaneous flux, such as n_TOFEAR2, with detection systems with an enhanced detection sensitivity and high counting rate capabilities. This contribution reviews some of the latest detector developments in detection systems for (n,Îł) measurements at n_TOF, such as i-TED, an innovative detection system which exploits the Compton imaging technique to reduce the dominant neutron scattering background and s-TED, a highly segmented total energy detector intended for high flux facilities. The discussion will be illustrated with results of the first measurement of key the s-process branching-point reaction 79Se(n,Îł).Title in Web of Science: New detection systems for an enhanced sensitivity in key stellar (n,gamma) measurements</p
Measurement of the 154Gd(n,Îł) cross section and its astrophysical implications
The neutron capture cross section of Gd was measured from 1 eV to 300 keV in the experimental area located 185 m from the CERN n_TOF neutron spallation source, using a metallic sample of gadolinium, enriched to 67% in Gd. The capture measurement, performed with four CD scintillation detectors, has been complemented by a transmission measurement performed at the GELINA time-of-flight facility (JRC-Geel), thus minimising the uncertainty related to sample composition. An accurate Maxwellian averaged capture cross section (MACS) was deduced over the temperature range of interest for s process nucleosynthesis modelling. We report a value of 880(50) mb for the MACS at kT=30 keV, significantly lower compared to values available in literature. The new adopted Gd(n,Îł) cross section reduces the discrepancy between observed and calculated solar s-only isotopic abundances predicted by s-process nucleosynthesis models.The isotope used in this research was supplied by the United States Department of Energy Office of Science by the Isotope Pro-gram in the Office of Nuclear Physics.This research was supported by the EUFRAT open access pro-gramme of the Joint Research Centre at Geel
Measurement and analysis of Gd(n,) from thermal energy to 1 keV
International audienceWe have measured the capture cross section of the Gd and Gd isotopes between 0.025 eV and 1 keV. The capture events were recorded by an array of 4 CD detectors, and the capture yield was deduced exploiting the total energy detection system in combination with the Pulse Height Weighting Techniques. Because of the large cross section around thermal neutron energy, 4 metallic samples of different thickness were used to prevent problems related to self-shielding. The samples were isotopically enriched, with a cross contamination of the other isotope of less than 1.14%. The capture yield was analyzed with an R-Matrix code to describe the cross section in terms of resonance parameters. Near thermal energies, the results are significantly different from evaluations and from previous time-of-flight experiments. The data from the present measurement at n_TOF are publicly available in the experimental nuclear reaction database EXFOR.</jats:p