8 research outputs found

    Subcutaneous dissociative conscious sedation (sDCS) an alternative method for airway regional blocks: a new approach

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Predicted difficult airway is a definite indication for awake intubation and spontaneous ventilation. Airway regional blocks which are commonly used to facilitate awake intubation are sometimes impossible or forbidden. On the other hand deep sedation could be life threatening in the case of compromised airway.</p> <p>The aim of this study is evaluating "Subcutaneous Dissociative Conscious Sedation" (sDCS) as an alternative method to airway regional blocks for awake intubation.</p> <p>Methods</p> <p>In this prospective, non-randomized study, 30 patients with predicted difficult airway (laryngeal tumors), who were scheduled for direct laryngoscopic biopsy (DLB), underwent "Subcutaneous Dissociative Conscious Sedation" (sDCS) exerted by intravenous fentanyl 3-4ug/kg and subcutaneous ketamine 0.6-0.7 mg/kg. The tongue and pharynx were anesthetized with lidocaine spray (4%<b>)</b>. 10 minutes after a subcutaneous injection of ketamine direct laryngoscopy was performed. Extra doses of fentanyl 50-100 ug were administered if the patient wasn't cooperative enough for laryngoscopy.</p> <p>Patients were evaluated for hemodynamic stability (heart rate and blood pressure), oxygen saturation (Spo<sub>2</sub>), patient cooperation (obedient to open the mouth for laryngoscopy and the number of tries for laryngoscopy), patient comfort (remaining moveless), hallucination, nystagmus and salivation (need for aspiration before laryngoscopy).</p> <p>Results</p> <p>Direct laryngoscopy was performed successfully in all patients. One patient needed extra fentanyl and then laryngoscopy was performed successfully on the second try. All patients were cooperative enough during laryngoscopy. Hemodynamic changes more than 20% occurred in just one patient. Oxygen desaturation (spo<sub>2</sub>< 90%) didn't occur in any patient.</p> <p>Conclusions</p> <p>Subcutaneous Dissociative Conscious Sedation (sDCS) as a new approach to airway is an acceptable and safe method for awake intubation and it can be suggested as a noninvasive substitute of low complication rate for regional airway blocks.</p> <p>Registration ID in IRCT</p> <p>IRCT201012075333N1</p

    Novel use of an exchange catheter to facilitate intubation with an Aintree catheter in a tall patient with a predicted difficult airway: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>The Aintree intubating catheter (Cook<sup>® </sup>Medical Inc., Bloomington, IN, USA) has been shown to successfully facilitate difficult intubations when other methods have failed. The Aintree intubating catheter (Cook<sup>® </sup>Medical Inc., Bloomington, IN, USA) has a fixed length of 56 cm, and it has been suggested in the literature that it may be too short for safe use in patients who are tall.</p> <p>Case presentation</p> <p>We present the case of a 32-year-old, 180 cm tall Caucasian woman with a predicted difficult airway who presented to our facility for an emergency cesarean section. After several failed intubation attempts via direct laryngoscopy, an airway was established with a laryngeal mask airway. After delivery of a healthy baby, our patient's condition necessitated tracheal intubation. A fiber-optic bronchoscope loaded with an Aintree intubating catheter (Cook<sup>® </sup>Medical Inc., Bloomington, IN, USA) was passed through the laryngeal mask airway into the trachea until just above the carina, but was too short to safely allow for the passage of an endotracheal tube.</p> <p>Conclusions</p> <p>We present a novel technique in which the Aintree intubating catheter (Cook<sup>® </sup>Medical Inc., Bloomington, IN, USA) was replaced with a longer (100 cm) exchange catheter, over which an endotracheal tube was passed successfully into the trachea.</p
    corecore