309 research outputs found

    Testbeam and Laboratory Characterization of CMS 3D Pixel Sensors

    Full text link
    The pixel detector is the innermost tracking device in CMS, reconstructing interaction vertices and charged particle trajectories. The sensors located in the innermost layers of the pixel detector must be upgraded for the ten-fold increase in luminosity expected with the High- Luminosity LHC (HL-LHC) phase. As a possible replacement for planar sensors, 3D silicon technology is under consideration due to its good performance after high radiation fluence. In this paper, we report on pre- and post- irradiation measurements for CMS 3D pixel sensors with different electrode configurations. The effects of irradiation on electrical properties, charge collection efficiency, and position resolution of 3D sensors are discussed. Measurements of various test structures for monitoring the fabrication process and studying the bulk and surface properties, such as MOS capacitors, planar and gate-controlled diodes are also presented.Comment: 14 page

    The INFN-FBK "Phase-2" R&D program

    Get PDF
    We report on the 3-year INFN ATLAS-CMS joint research activity in collaboration with FBK, started in 2014, and aimed at the development of new thin pixel detectors for the High Luminosity LHC Phase-2 upgrades. The program is concerned with both 3D and planar active-edge pixel sensors to be made on 6" p-type wafers. The technology and the design will be optimized and qualified for extreme radiation hardness (2×1016 neq cm-2). Pixel layouts compatible with present (for testing) and future (RD53 65nm) front-end chips of ATLAS and CMS are considered. The paper covers the main aspects of the research program, from the sensor design and fabrication technology, to the results of initial tests performed on the first prototypes. © 2015 Elsevier B.V

    The second production of RSD (AC-LGAD) at FBK

    Full text link
    In this contribution we describe the second run of RSD (Resistive AC-Coupled Silicon Detectors) designed at INFN Torino and produced by Fondazione Bruno Kessler (FBK), Trento. RSD are n-in-p detectors intended for 4D particle tracking based on the LGAD technology that get rid of any segmentation implant in order to achieve the 100% fill-factor. They are characterized by three key-elements, (i) a continuous gain implant, (ii) a resistive n-cathode and (iii) a dielectric coupling layer deposited on top, guaranteeing a good spatial reconstruction of the hit position while benefiting from the good timing properties of LGADs. We will start from the very promising results of our RSD1 batch in terms of tracking performances and then we will move to the description of the design of the RSD2 run. In particular, the principles driving the sensor design and the specific AC-electrode layout adopted to optimize the signal confinement will be addressed

    Prototype ATLAS IBL Modules using the FE-I4A Front-End Readout Chip

    Get PDF
    The ATLAS Collaboration will upgrade its semiconductor pixel tracking detector with a new Insertable B-layer (IBL) between the existing pixel detector and the vacuum pipe of the Large Hadron Collider. The extreme operating conditions at this location have necessitated the development of new radiation hard pixel sensor technologies and a new front-end readout chip, called the FE-I4. Planar pixel sensors and 3D pixel sensors have been investigated to equip this new pixel layer, and prototype modules using the FE-I4A have been fabricated and characterized using 120 GeV pions at the CERN SPS and 4 GeV positrons at DESY, before and after module irradiation. Beam test results are presented, including charge collection efficiency, tracking efficiency and charge sharing.Comment: 45 pages, 30 figures, submitted to JINS

    Beam test results of 25 and 35 ÎĽ m thick FBK ultra-fast silicon detectors

    Get PDF
    This paper presents the measurements on first very thin Ultra-Fast Silicon Detectors (UFSDs) produced by Fondazione Bruno Kessler; the data have been collected in a beam test setup at the CERN PS, using beam with a momentum of 12 GeV/c. UFSDs with a nominal thickness of 25 and 35 mu m and an area of 1 x 1 mm(2) have been considered, together with an additional HPK 50-mu m thick sensor, taken as reference. Their timing performances have been studied as a function of the applied voltage and gain. A time resolution of about 25 ps and of 22 ps at a voltage of 120 and 240 V has been obtained for the 25 and 35 mu m thick UFSDs, respectively

    Is Lactoferrin More Effective in Reducing Late-Onset Sepsis in Preterm Neonates Fed Formula Than in Those Receiving Mother's Own Milk? Secondary Analyses of Two Multicenter Randomized Controlled Trials

    Get PDF
    Background: Lactoferrin is the major antimicrobial protein in human milk. In our randomized controlled trial (RCT) of bovine lactoferrin (BLF) supplementation in preterm neonates, BLF reduced late-onset sepsis (LOS). Mother's own milk (MM) contains higher concentrations of lactoferrin than donor milk or formula, but whether BLF is more effective in infants who receive formula or donor milk is uncertain. Aim: To evaluate the incidence of LOS in preterm infants fed MM and in those fed formula and/or donor milk. Study Design: This is a (A) post hoc subgroup analysis, in our RCT of BLF, of its effects in preterm infants fed MM, with or without formula, versus those fed formula and/or donor milk (no-MM) and (B) post hoc meta-analysis, in our RCT of BLF and in the ELFIN (Enteral Lactoferrin in Neonates) RCT, of the effect of BLF in subgroups not exclusively fed MM. Results (A) Of 472 infants in our RCT, 168 were randomized to placebo and 304 were randomized to BLF. Among MM infants, LOS occurred in 22/133 (16.5%) infants randomized to placebo and in 14/250 (5.6%) randomized to BLF (relative risk or risk ratio (RR): 0.34; relative risk reduction (RRR): 0.66; 95% confidence interval (95% CI) for RR: 0.18-0.64; p < 0.0008). Among no-MM infants, LOS occurred in 7/35 (20.0%) randomized to placebo and in 2/54 (3.7%) randomized to BLF (RR: 0.19; RRR: 0.81; 95% CI for RR: 0.16-0.96; p = 0.026). In multivariable logistic regression analysis, there was no interaction between BLF treatment effect and type of feeding (p = 0.628). (B) In 1,891 infants not exclusively fed MM in our RCT of BLF and in the ELFIN RCT, BLF reduced the RR of LOS by 18% (RR: 0.82; 95% CI: 0.71-0.96; p = 0.01). Conclusion: Adequately powered studies should address the hypothesis that BLF is more effective in infants fed formula or donor milk than those fed MM. Such studies should evaluate whether a specific threshold of total lactoferrin intake can be identified to protect such patients from LOS

    Total Dose Dependence of Oxide Charge, Interstrip Capacitance and Breakdown Behavior of sLHC Prototype Silicon Strip Detectors and Test Structures of the SMART Collaboration

    Get PDF
    Abstract For the future luminosity upgrade proposed for the Large Hadron Collider (LHC) silicon strip detectors (SSD) and test structures were fabricated on various high-resistivity substrates (p-type MCz and FZ, n-type FZ) within the INFN funded SMART project. They were irradiated with 60 Co to test total dose (TID) effects, in order to study the impact of surface radiation damage on the detector properties (interstrip capacitance and resistance, break-down voltage). Selected results from the pre-rad and post-rad characterization of detectors and test structures are presented, in particular interstrip capacitance, breakdown voltage, flatband voltage and oxide charge. They show saturation at about 150 kRad. Annealing are performed both at room and at elevated temperature

    Encoding order and developmental dyslexia:a family of skills predicting different orthographic components

    Get PDF
    We investigated order encoding in developmental dyslexia using a task that presented nonalphanumeric visual characters either simultaneously or sequentially—to tap spatial and temporal order encoding, respectively—and asked participants to reproduce their order. Dyslexic participants performed poorly in the sequential condition, but normally in the simultaneous condition, except for positions most susceptible to interference. These results are novel in demonstrating a selective difficulty with temporal order encoding in a dyslexic group. We also tested the associations between our order reconstruction tasks and: (a) lexical learning and phonological tasks; and (b) different reading and spelling tasks. Correlations were extensive when the whole group of participants was considered together. When dyslexics and controls were considered separately, different patterns of association emerged between orthographic tasks on the one side and tasks tapping order encoding, phonological processing, and written learning on the other. These results indicate that different skills support different aspects of orthographic processing and are impaired to different degrees in individuals with dyslexia. Therefore, developmental dyslexia is not caused by a single impairment, but by a family of deficits loosely related to difficulties with order. Understanding the contribution of these different deficits will be crucial to deepen our understanding of this disorder
    • …
    corecore