1,170 research outputs found
Composition of primary cosmic rays near the bend from a study of hadrons in air showers at sea level
Data on hadrons in air showers arriving at sea level were studied to find sensitivity to primary cosmic ray composition. The rate of showers which satisfy minimum shower density and hadron energy requirements as well as the rate of showers containing hadrons delayed with respect to the electron shower front are compared to Monte Carlo simulations. The data on the rate of total triggers and delayed hadrons are compared to predicted rates for two models of primary composition. The data are consistent with models which require an increasing heavy nuclei fraction near 10 to the 15th power eV. The spectra which are consistent with the observed rate are also compared to the observed shower size spectrum at sea level and mountain level
The Intrinsic Origin of Spin Echoes in Dipolar Solids Generated by Strong Pi Pulses
In spectroscopy, it is conventional to treat pulses much stronger than the
linewidth as delta-functions. In NMR, this assumption leads to the prediction
that pi pulses do not refocus the dipolar coupling. However, NMR spin echo
measurements in dipolar solids defy these conventional expectations when more
than one pi pulse is used. Observed effects include a long tail in the CPMG
echo train for short delays between pi pulses, an even-odd asymmetry in the
echo amplitudes for long delays, an unusual fingerprint pattern for
intermediate delays, and a strong sensitivity to pi-pulse phase. Experiments
that set limits on possible extrinsic causes for the phenomena are reported. We
find that the action of the system's internal Hamiltonian during any real pulse
is sufficient to cause the effects. Exact numerical calculations, combined with
average Hamiltonian theory, identify novel terms that are sensitive to
parameters such as pulse phase, dipolar coupling, and system size.
Visualization of the entire density matrix shows a unique flow of quantum
coherence from non-observable to observable channels when applying repeated pi
pulses.Comment: 24 pages, 27 figures. Revised from helpful referee comments. Added
new Table IV, new paragraphs on pages 3 and 1
Milagro: A TeV observatory for gamma-ray bursts
Observation of prompt TeV γ-rays from GRBs requires a new type of detector to overcome the low duty factor and small field of view of current TeV observatories. Milagro is such a new type of very high energy (\u3e a few 100 GeV) gamma-ray observatory, which has a large field of view of \u3e1 steradian and 24 hours/day operation. Milagrito, a prototype for Milagro, was operated from February 1997 to May 1998. During the summer of 1998, Milagrito was dismantled and Milagro was built. Both detectors use a 80 m×60 m×8 m pond of water in which a 3 m×3 m grid of photomultiplier tubes detects the Cherenkov light produced in the water by the relativistic particles in extensive air showers. Milagrito was smaller and had only one layer of photomultipliers, but allowed the technique to be tested. Milagrito observations of the Moon’s shadow and Mrk 501 are consistent with the Monte Carlo prediction of the telescope’s parameters, such as effective area and angular resolution. Milagro will have improved flux sensitivity over Milagrito due to larger effective area, better angular resolution and cosmic-ray background rejection
First results of a study of TeV emission from GRBs in Milagrito
Milagrito, a detector sensitive to γ-rays at TeV energies, monitored the northern sky during the period February 1997 through May 1998. With a large field of view and high duty cycle, this instrument was used to perform a search for TeV counterparts to γ-ray bursts. Within the Milagrito field of view 54 γ-ray bursts at keV energies were observed by the Burst And Transient Satellite Experiment (BATSE) aboard the Compton Gamma-Ray Observatory. This paper describes the results of a preliminary analysis to search for TeV emission correlated with BATSE detected bursts. Milagrito detected an excess of events coincident both spatially and temporally with GRB 970417a, with chance probability 2.8×10−5 within the BATSE error radius. No other significant correlations were detected. Since 54 bursts were examined the chance probability of observing an excess with this significance in any of these bursts is 1.5×10−3. The statistical aspects and physical implications of this result are discussed
Evidence for TeV Emission from GRB 970417a
Milagrito, a detector sensitive to very high energy gamma rays, monitored the
northern sky from February 1997 through May 1998. With a large field of view
and a high duty cycle, this instrument was well suited to perform a search for
TeV gamma-ray bursts (GRBs). We report on a search made for TeV counterparts to
GRBs observed by BATSE. BATSE detected 54 GRBs within the field of view of
Milagrito during this period. An excess of events coincident in time and space
with one of these bursts, GRB 970417a, was observed by Milagrito. The excess
has a chance probability of of being a fluctuation of the
background. The probability for observing an excess at least this large from
any of the 54 bursts is . No significant correlations were
detected from the other bursts.Comment: 10 pages, 3 figure
Detection of 6 November 1997 ground level event by Milagrito
Solar Energetic Particles (SEPs) with energies exceeding 10 GeV associated with the 6 November 1997 solar flare/CME (coronal mass ejection) have been detected with Milagrito, a prototype of the Milagro Gamma Ray Observatory. While SEP acceleration beyond 1 GeV is well established, few data exist for protons or ions beyond 10 GeV. The Milagro observatory, a ground based water Cherenkov detector designed for observing very high energy gamma ray sources, can also be used to study the Sun. Milagrito, which operated for approximately one year in 1997/98, was sensitive to solar proton and neutron fluxes above ∼4 GeV. In its scaler mode, Milagrito registered a rate increase coincident with the 6 November 1997 ground level event observed by Climax and other neutron monitors. A preliminary analysis suggests the presence of \u3e10 GeV particles
Calibration of the Milagro Cosmic Ray Telescope
The Milagro detector is an air shower array which uses the water Cherenkov
technique and is capable of continuously monitoring the sky at energies near 1
TeV. The detector consists of 20000 metric tons of pure water instrumented with
723 photo-multiplier tubes (PMTs). The PMTs are arranged in a two-layer
structure on a lattice of 3 m spacing covering 5000 area. The direction
of the shower is determined from the relative timing of the PMT signals,
necessitating a common time reference and amplitude slewing corrections to
improve the time resolution. The calibration system to provide these consists
of a pulsed laser driving 30 diffusing light sources deployed in the pond to
allow cross-calibration of the PMTs. The system is capable of calibrating times
and the pulse-heights from the PMTs using the time-over-threshold technique.
The absolute energy scale is provided using single muons passing through the
detector. The description of the calibration system of the Milagro detector and
its prototype Milagrito will be presented.Comment: 4 pages, submitted to the XXVI International Cosmic Ray Conferenc
Milagro: A TeV gamma-ray monitor of the Northern Hemisphere Sky
A new type of very high energy (\u3e a few 100 GeV) gamma-ray observatory, Milagro, has been built with a large field of view of \u3e1 steradian and nearly 24 hours/day operation. Milagrito, a prototype for Milagro, was operated from February 1997 to May 1998. During the summer of 1998, Milagrito was dismantled and Milagro was built. Both detectors use a 80 m×60 m×8 mpond of water in which a 3 m×3 m grid of photomultiplier tubes detects the Cherenkov light produced in the water by the relativistic particles in extensive air showers. Milagrito was smaller and had only one layer of photomultipliers, but allowed the technique to be tested. Milagrito observations of the Moon’s shadow and Mrk 501 are consistent with the Monte Carlo prediction of the telescopes parameters, such as effective area and angular resolution. Milagro is larger and consists of two layers of photomultiplier tubes. The bottom layer detects penetrating particles that are used to reject the background of cosmic-ray initiated showers
Observation of TeV Gamma Rays from the Crab Nebula with Milagro Using a New Background Rejection Technique
The recent advances in TeV gamma-ray astronomy are largely the result of the
ability to differentiate between extensive air showers generated by gamma rays
and hadronic cosmic rays. Air Cherenkov telescopes have developed and perfected
the "imaging" technique over the past several decades. However until now no
background rejection method has been successfully used in an air shower array
to detect a source of TeV gamma rays. We report on a method to differentiate
hadronic air showers from electromagnetic air showers in the Milagro gamma ray
observatory, based on the ability to detect the energetic particles in an
extensive air shower. The technique is used to detect TeV emission from the
Crab nebula. The flux from the Crab is estimated to be 2.68(+-0.42stat +-
1.4sys) x10^{-7} (E/1TeV)^{-2.59} m^{-2} s^{-1} TeV^{-1}, where the spectral
index is assumed to be as given by the HEGRA collaboration.Comment: 22 pages, 11 figures, submitted to Astrophysical Journa
The Milagro gamma-ray observatory
The Milagro water Cherenkov detector began full operation in January 2000. This detector is capable of monitoring the Northern sky at energies above 500 GeV for sources of equivalent strength to the Crab Nebula over one year of integration. We report on the current performance and sensitivity of Milagro
- …