473 research outputs found

    DFT and experimental investigations on the photocatalytic activities of NiO nanobelts for removal of organic pollutants

    Get PDF
    NiO nanobelts synthesized using the hydrothermal method are explored for photocatalytic degradation of organic pollutants like RhB, MO, MB, and CV. The XPS analysis confirmed the formation of the stoichiometric NiO nanobelts. Few micrometer long cubic crystalline NiO nanobelts of the average thickness of ∼75 nm delivered a bandgap of 4.07 eV. The FTIR studies revealed that the mesoporous NiO nanobelts delivered stable photocatalytic activities after controlled irradiation under a xenon lamp. The kinetic studies showed the 79.1, 82.7, 76.7, and 89% degradation of MO, MB, CV, and RhB after 140 min at the rate constants (k) of 0.007, 0.008, 0.009, and 0.012 min−1, respectively. Complementary first-principles Density Functional Theory (DFT) and scavenging studies revealed the chemical picture and influence of the , and photogenerated from NiO nanobelts in the photocatalytic degradation of organic dyes. These studies corroborate the use of the NiO nanobelts in the stable and eco-friendly photocatalytic degradation activities of a wide range of organic pollutants

    METALLOGRAPHIC EXAMINATION OF ORNL NO. 1, SHE NO. 2

    Full text link
    Small Heat Exchanger ORNL No. I, type SHE No. 2, was removed from test stand B after 2071 hours of operation; 1041 hours were under 4 T conditions. The heat exchanger contatned 20 Inconel tubes having an outside diameter of 0.25 in. and a wall thickness of 0.025 in. The outside of these tubes was exposed to the fluoride mixture NaF contained NaK (44% Na--56% K). During o degradation t T conditions, the fluoride temperature entering the heat exchanger was 1310 tained F and on leaving was 1235 tained F. The temperature of the NaK entering the heat exchanger was 1050 tained F and at the exit was 1290 tained F. During isothermal operation, the temperature of both the NaK and fluoride circuits was 1300 tained F. Thirtysix termperature transitions from isothermal to o degradation t T conditions were made during the course of operation. An examination of the resistance heater used in conjunction with this heat exchanger also was made: the results are reported. (auth

    A tuberculosis prevalence survey based on symptoms questioning and sputum examination

    Get PDF
    A sample survey was undertaken in Raichur district of Karnataka State to estimate the prevalence of bacteriologically positive pulmonary tuberculosis among symptomatics aged 15 years and above. A population of 72,448 persons was registered in a representative sample of 57 villages and 21 enumeration blocks. Of the 42,580 persons aged 15 years and above eligible for symptoms questioning, 40,657 (95.5%) were examined and 3,846 (9.5%) were found to be symptomatics and eligible for sputum examination. Sputum was collected from 3,685 (95.8%) of the 3,846 symptomatics, and subjected to bacteriological examination i.e., smear, culture and drug susceptibility. Certain important findings were as follows: (i) the number of symptomatics increased with increase in age, more often among males (11.9%) than among females (7.1%), (ii) the prevalence of tuberculosis, as assessed by smear and/or culture was 10.9 per 1,000 in population aged 15 years and above, (iii) the prevalence increased with age and was 3 times higher among males as compared to females, (iv) cough was found to be the predominant symptom among the symptomatics (87%) as well as among the cases detected (92%), (v) the prevalence rate based on smear examination of the sputum specimens, using the two microscopy methods (Ziehl-Neelsen and Fluorescence) was 7.6 per 1,000, (vi) culture examination of these specimens yielded 3.3 per 1,100 additional cases, (vii) both the microscopy methods were equally efficient in detecting smear positives, (vii) of the 355 culture positive cases, 17.7% were resistant to Streptomycin, 29.6% to Isoniazid and 7.6% to Rifampicin either alone or in combination with other drugs

    First measurement of muon-neutrino disappearance in NOvA

    Get PDF
    This paper reports the first measurement using the NOvA detectors of nu(mu) disappearance in a nu(mu) beam. The analysis uses a 14 kton-equivalent exposure of 2.74 x 10(20) protons-on-target from the Fermilab NuMI beam. Assuming the normal neutrino mass hierarchy, we measure Delta m(32)(2) = (2.52(-0.18)(+0.20)) x 10(-3) eV(2) and sin(2) theta(23) in the range 0.38-0.65, both at the 68% confidence level, with two statistically degenerate best-fit points at sin(2) theta(23) = 0.43 and 0.60. Results for the inverted mass hierarchy are also presented

    Mass Dependence of M3Y-Type Interactions and the Effects of Tensor Correlations

    Get PDF
    The mass dependence of the M3Y-type effective interactions and the effects of tensor correlations are examined. Two-body nuclear matrix elements are obtained by the lowest order constrained variational (LOCV) technique with and without tensor correlations. We have found that the tensor correlations are important especially in the triplet-even (TE) and tensor-even (TNE) channels in order to reproduce the G-matrix elements obtained previously. Then M3Y-type potentials for inelastic scattering are obtained by fitting our two-body matrix elements to those of a sum of Yukawa functions for the mass numbers A=24, A=40 and A=90.Comment: 13 pages, 6 table

    The MINERν\nuA Data Acquisition System and Infrastructure

    Full text link
    MINERν\nuA (Main INjector ExpeRiment ν\nu-A) is a new few-GeV neutrino cross section experiment that began taking data in the FNAL NuMI (Fermi National Accelerator Laboratory Neutrinos at the Main Injector) beam-line in March of 2010. MINERν\nuA employs a fine-grained scintillator detector capable of complete kinematic characterization of neutrino interactions. This paper describes the MINERν\nuA data acquisition system (DAQ) including the read-out electronics, software, and computing architecture.Comment: 34 pages, 16 figure
    • …
    corecore