16 research outputs found
A risk-adjusted and anatomically stratified cohort comparison study of open surgery, endovascular techniques and medical management for juxtarenal aortic aneurysms-the UK COMPlex AneurySm Study (UK-COMPASS): a study protocol.
Funder: Health Technology Assessment Programme; Grant(s): Award ID: 15/153/02INTRODUCTION: In one-third of all abdominal aortic aneurysms (AAAs), the aneurysm neck is short (juxtarenal) or shows other adverse anatomical features rendering operations more complex, hazardous and expensive. Surgical options include open surgical repair and endovascular aneurysm repair (EVAR) techniques including fenestrated EVAR, EVAR with adjuncts (chimneys/endoanchors) and off-label standard EVAR. The aim of the UK COMPlex AneurySm Study (UK-COMPASS) is to answer the research question identified by the National Institute for Health Research Health Technology Assessment (NIHR HTA) Programme: 'What is the clinical and cost-effectiveness of strategies for the management of juxtarenal AAA, including fenestrated endovascular repair?' METHODS AND ANALYSIS: UK-COMPASS is a cohort study comparing clinical and cost-effectiveness of different strategies used to manage complex AAAs with stratification of physiological fitness and anatomical complexity, with statistical correction for baseline risk and indication biases. There are two data streams. First, a stream of routinely collected data from Hospital Episode Statistics and National Vascular Registry (NVR). Preoperative CT scans of all patients who underwent elective AAA repair in England between 1 November 2017 and 31 October 2019 are subjected to Corelab analysis to accurately identify and include every complex aneurysm treated. Second, a site-reported data stream regarding quality of life and treatment costs from prospectively recruited patients across England. Site recruitment also includes patients with complex aneurysms larger than 55 mm diameter in whom an operation is deferred (medical management). The primary outcome measure is perioperative all-cause mortality. Follow-up will be to a median of 5 years. ETHICS AND DISSEMINATION: The study has received full regulatory approvals from a Research Ethics Committee, the Confidentiality Advisory Group and the Health Research Authority. Data sharing agreements are in place with National Health Service Digital and the NVR. Dissemination will be via NIHR HTA reporting, peer-reviewed journals and conferences. TRIAL REGISTRATION NUMBER: ISRCTN85731188
Aspects of microbial communities in peatland carbon cycling under changing climate and land use pressures
This is the final version. Available on open access from the Finnish Peatland Society via the DOI in this record. Globally, major efforts are being made to restore peatlands to maximise their resilience to anthropogenic climate change, which puts continuous pressure on peatland ecosystems and modifies the geography of the environmental envelope that underpins peatland functioning. A probable effect of climate change is reduction in the waterlogged conditions that are key to peatland formation and continued accumulation of carbon (C) in peat. C sequestration in peatlands arises from a delicate imbalance between primary production and decomposition, and microbial processes are potentially pivotal in regulating feedbacks between environmental change and the peatland C cycle. Increased soil temperature, caused by climate warming or disturbance of the natural vegetation cover and drainage, may result in reductions of long-term C storage via changes in microbial community composition and metabolic rates. Moreover, changes in water table depth alter the redox state and hence have broad consequences for microbial functions, including effects on fungal and bacterial communities especially methanogens and methanotrophs. This article is a perspective review of the effects of climate change and ecosystem restoration on peatland microbial communities and the implications for C sequestration and climate regulation. It is authored by peatland scientists, microbial ecologists, land managers and non-governmental organisations who were attendees at a series of three workshops held at The University of Manchester (UK) in 2019–2020. Our review suggests that the increase in methane flux sometimes observed when water tables are restored is predicated on the availability of labile carbon from vegetation and the absence of alternative terminal electron acceptors. Peatland microbial communities respond relatively rapidly to shifts in vegetation induced by climate change and subsequent changes in the quantity and quality of below-ground C substrate inputs. Other consequences of climate change that affect peatland microbial communities and C cycling include alterations in snow cover and permafrost thaw. In the face of rapid climate change, restoration of a resilient microbiome is essential to sustaining the climate regulation functions of peatland systems. Technological developments enabling faster characterisation of microbial communities and functions support progress towards this goal, which will require a strongly interdisciplinary approach.Natural Environment Research Council (NERC
Editor's Choice - Comparison of Open Surgery and Endovascular Techniques for Juxtarenal and Complex Neck Aortic Aneurysms: The UK COMPlex AneurySm Study (UK-COMPASS) - Peri-operative and Midterm Outcomes.
ObjectiveTreatment of juxtarenal and complex neck abdominal aortic aneurysms (AAAs) is now commonly by endovascular rather than open surgical repair (OSR). Published comparisons show poor validity and scientific precision. UK-COMPASS is a comparative cohort study of endovascular treatments vs. OSR for patients with an AAA unsuitable for standard on label endovascular aneurysm repair (EVAR).MethodsAll procedures for AAA in England (November 2017 to October 2019) were identified, AAA anatomy assessed in a Corelab, peri-operative risk scores determined, and propensity scoring used to identify patients suitable for either endovascular treatment or OSR. Patients were stratified by aneurysm neck length (0 - 4 mm, 5 - 9 mm, or ≥ 10 mm) and operative risk; the highest quartile was considered high risk and the remainder standard risk. Death was the primary outcome measure. Endovascular treatments included fenestrated EVAR (FEVAR) and off label standard EVAR (± adjuncts).ResultsAmong 8 994 patients, 2 757 had AAAs that were juxtarenal, short neck, or complex neck in morphology. Propensity score stratification and adjustment method comparisons included 1 916 patients. Widespread off label use of standard EVAR devices was noted (35.6% of patients). The adjusted peri-operative mortality rate was 2.9%, lower for EVAR (1.2%; p = .001) and FEVAR (2.2%; p = .001) than OSR (4.5%). In standard risk patients with a 0 - 4 mm neck, the mortality rate was 7.4% following OSR and 2.3% following FEVAR. Differences were smaller for patients with a neck length ≥ 5 mm: 2.1% OSR vs. 1.0% FEVAR. At 3.5 years of follow up, the overall mortality rate was 20.7% in the whole study population, higher following FEVAR (27.6%) and EVAR (25.2%) than after OSR (14.2%). However, in the 0 - 4 mm neck subgroup, overall survival remained equivalent. The aneurysm related mortality rate was equivalent between treatments, but re-intervention was more common after EVAR and FEVAR than OSR.ConclusionFEVAR proves notably safer than OSR in the peri-operative period for juxtarenal aneurysms (0 - 4 mm neck length), with comparable midterm survival. For patients with short neck (5 - 9 mm) and complex neck (≥ 10 mm) AAAs, overall survival was worse in endovascularly treated patients compared with OSR despite relative peri-operative safety. This warrants further research and a re-appraisal of the current clinical application of endovascular strategies, particularly in patients with poor general survival outlook owing to comorbidity and age
Comparison of Open Surgery and Endovascular Techniques for Juxtarenal and Complex Neck Aortic Aneurysms: The UK COMPlex AneurySm Study (UK-COMPASS) - Peri-operative and Midterm Outcomes
OBJECTIVE: Treatment of juxtarenal and complex neck abdominal aortic aneurysms (AAAs) is now commonly by endovascular rather than open surgical repair (OSR). Published comparisons show poor validity and scientific precision. UK-COMPASS is a comparative cohort study of endovascular treatments vs. OSR for patients with an AAA unsuitable for standard on label endovascular aneurysm repair (EVAR). METHODS: All procedures for AAA in England (November 2017 to October 2019) were identified, AAA anatomy assessed in a Corelab, peri-operative risk scores determined, and propensity scoring used to identify patients suitable for either endovascular treatment or OSR. Patients were stratified by aneurysm neck length (0 - 4 mm, 5 - 9 mm, or = 10 mm) and operative risk; the highest quartile was considered high risk and the remainder standard risk. Death was the primary outcome measure. Endovascular treatments included fenestrated EVAR (FEVAR) and off label standard EVAR (± adjuncts). RESULTS: Among 8 994 patients, 2 757 had AAAs that were juxtarenal, short neck, or complex neck in morphology. Propensity score stratification and adjustment method comparisons included 1 916 patients. Widespread off label use of standard EVAR devices was noted (35.6% of patients). The adjusted peri-operative mortality rate was 2.9%, lower for EVAR (1.2%; p = .001) and FEVAR (2.2%; p = .001) than OSR (4.5%). In standard risk patients with a 0 - 4 mm neck, the mortality rate was 7.4% following OSR and 2.3% following FEVAR. Differences were smaller for patients with a neck length = 5 mm: 2.1% OSR vs. 1.0% FEVAR. At 3.5 years of follow up, the overall mortality rate was 20.7% in the whole study population, higher following FEVAR (27.6%) and EVAR (25.2%) than after OSR (14.2%). However, in the 0 - 4 mm neck subgroup, overall survival remained equivalent. The aneurysm related mortality rate was equivalent between treatments, but re-intervention was more common after EVAR and FEVAR than OSR. CONCLUSION: FEVAR proves notably safer than OSR in the peri-operative period for juxtarenal aneurysms (0 - 4 mm neck length), with comparable midterm survival. For patients with short neck (5 - 9 mm) and complex neck (= 10 mm) AAAs, overall survival was worse in endovascularly treated patients compared with OSR despite relative peri-operative safety. This warrants further research and a re-appraisal of the current clinical application of endovascular strategies, particularly in patients with poor general survival outlook owing to comorbidity and age.Published version, accepted version (12 months embrago)The article is available via Open Access. Click on the 'Additional link' above to access the full-text
Editor's Choice – Comparison of Open Surgery and Endovascular Techniques for Juxtarenal and Complex Neck Aortic Aneurysms: The UK COMPlex AneurySm Study (UK-COMPASS) – Peri-operative and Midterm Outcomes
Objective: Treatment of juxtarenal and complex neck abdominal aortic aneurysms (AAAs) is now commonly by endovascular rather than open surgical repair (OSR). Published comparisons show poor validity and scientific precision. UK-COMPASS is a comparative cohort study of endovascular treatments vs. OSR for patients with an AAA unsuitable for standard on label endovascular aneurysm repair (EVAR). Methods: All procedures for AAA in England (November 2017 to October 2019) were identified, AAA anatomy assessed in a Corelab, peri-operative risk scores determined, and propensity scoring used to identify patients suitable for either endovascular treatment or OSR. Patients were stratified by aneurysm neck length (0 – 4 mm, 5 – 9 mm, or ≥ 10 mm) and operative risk; the highest quartile was considered high risk and the remainder standard risk. Death was the primary outcome measure. Endovascular treatments included fenestrated EVAR (FEVAR) and off label standard EVAR (± adjuncts). Results: Among 8 994 patients, 2 757 had AAAs that were juxtarenal, short neck, or complex neck in morphology. Propensity score stratification and adjustment method comparisons included 1 916 patients. Widespread off label use of standard EVAR devices was noted (35.6% of patients). The adjusted peri-operative mortality rate was 2.9%, lower for EVAR (1.2%; p = .001) and FEVAR (2.2%; p = .001) than OSR (4.5%). In standard risk patients with a 0 – 4 mm neck, the mortality rate was 7.4% following OSR and 2.3% following FEVAR. Differences were smaller for patients with a neck length ≥ 5 mm: 2.1% OSR vs. 1.0% FEVAR. At 3.5 years of follow up, the overall mortality rate was 20.7% in the whole study population, higher following FEVAR (27.6%) and EVAR (25.2%) than after OSR (14.2%). However, in the 0 – 4 mm neck subgroup, overall survival remained equivalent. The aneurysm related mortality rate was equivalent between treatments, but re-intervention was more common after EVAR and FEVAR than OSR. Conclusion: FEVAR proves notably safer than OSR in the peri-operative period for juxtarenal aneurysms (0 – 4 mm neck length), with comparable midterm survival. For patients with short neck (5 – 9 mm) and complex neck (≥ 10 mm) AAAs, overall survival was worse in endovascularly treated patients compared with OSR despite relative peri-operative safety. This warrants further research and a re-appraisal of the current clinical application of endovascular strategies, particularly in patients with poor general survival outlook owing to comorbidity and age.</p