10 research outputs found
613 cases of splenic rupture without risk factors or previously diagnosed disease: a systematic review
Background
Rupture of the spleen in the absence of trauma or previously diagnosed disease is largely ignored in the emergency literature and is often not documented as such in journals from other fields. We have conducted a systematic review of the literature to highlight the surprisingly frequent occurrence of this phenomenon and to document the diversity of diseases that can present in this fashion.
Methods
Systematic review of English and French language publications catalogued in Pubmed, Embase and CINAHL between 1950 and 2011.
Results
We found 613 cases of splenic rupture meeting the criteria above, 327 of which occurred as the presenting complaint of an underlying disease and 112 of which occurred following a medical procedure. Rupture appeared to occur spontaneously in histologically normal (but not necessarily normal size) spleens in 35 cases and after minor trauma in 23 cases. Medications were implicated in 47 cases, a splenic or adjacent anatomical abnormality in 31 cases and pregnancy or its complications in 38 cases.
The most common associated diseases were infectious (n = 143), haematologic (n = 84) and non-haematologic neoplasms (n = 48). Amyloidosis (n = 24), internal trauma such as cough or vomiting (n = 17) and rheumatologic diseases (n = 10) are less frequently reported. Colonoscopy (n = 87) was the procedure reported most frequently as a cause of rupture. The anatomic abnormalities associated with rupture include splenic cysts (n = 6), infarction (n = 6) and hamartomata (n = 5). Medications associated with rupture include anticoagulants (n = 21), thrombolytics (n = 13) and recombinant G-CSF (n = 10). Other causes or associations reported very infrequently include other endoscopy, pulmonary, cardiac or abdominal surgery, hysterectomy, peliosis, empyema, remote pancreato-renal transplant, thrombosed splenic vein, hemangiomata, pancreatic pseudocysts, splenic artery aneurysm, cholesterol embolism, splenic granuloma, congenital diaphragmatic hernia, rib exostosis, pancreatitis, Gaucher's disease, Wilson's disease, pheochromocytoma, afibrinogenemia and ruptured ectopic pregnancy.
Conclusions
Emergency physicians should be attuned to the fact that rupture of the spleen can occur in the absence of major trauma or previously diagnosed splenic disease. The occurrence of such a rupture is likely to be the manifesting complaint of an underlying disease. Furthermore, colonoscopy should be more widely documented as a cause of splenic rupture
Extramedullary fixation of 569 unstable intertrochanteric fractures: a randomized multicenter trial of the Medoff sliding plate versus three other screw-plate systems
We compared the efficacy of the Medoff sliding plate (MSP) with 3 other screw-plate systems for fixation of unstable intertrochanteric fractures in a randomized multicenter trial of 569 elderly patients. The MSP has biaxial dynamic capacity along both the neck and the shaft of the femur unlike the other systems, which lack dynamic capacity along the shaft. 268 fractures were operated on with the MSP, and 301 with the dynamic hip screw (DHS), with or without a trochanteric stabilizing plate (DHS/TSP) or with the dynamic condylar screw (DCS). The MSP had recently been shown to the surgeons.The patients in the groups were similar as regards age, domestic situation, preinjury walking ability and type of fracture. We followed the patients clinically and radiographically for at least 1 year. There was no significant difference in walking ability at follow-up or rate of return to home. Fixation failure occurred in 18/268 fractures operated on with the MSP, in 8/238 with the DHS, in 3/49 with the DHS/TSP and in 1/14 with the DCS. The difference in the rate of fixation failure was not statistically significant when the MSP group was compared to the 3 other groups. In 14 of the 18 fixation failures in the MSP group, the biaxial dynamic capacity of the MSP had not been used due to technical errors by surgeons, unfamiliar with the new method. No selection bias was found regarding fracture types in the 2 subgroups of patients with correct or inadequate biaxial dynamization. Extramedullary fixation of unstable intertrochanteric fractures with these implants showed a low failure rate. When using the MSP, biaxial dynamization must be correctly performed
Prevention of venous thromboembolism with an oral factor Xa inhibitor, YM150, after total hip arthroplasty. A dose finding study (ONYX-2).
BACKGROUND:
Anticoagulant prophylaxis substantially reduces the risk of venous thromboembolism (VTE) after major orthopedic surgery. The direct factor Xa inhibitor YM150 is currently under investigation for the prevention of VTE, stroke and ischemic vascular events in patients after orthopedic surgery, with atrial fibrillation and with acute coronary syndrome, respectively.
OBJECTIVES:
To investigate the efficacy and safety of YM150 for the prevention of VTE following elective total hip arthroplasty.
PATIENTS/METHODS:
Patients were randomized to postoperative, once-daily, oral YM150 (5, 10, 30, 60 or 120 mg) (double-blind) or preoperative subcutaneous (open label) enoxaparin (40 mg) for 5 weeks. The primary efficacy endpoint comprised VTE diagnosed by mandatory bilateral venography or verified symptomatic deep vein thrombosis (DVT) plus all deaths up to 9 days after surgery. The primary safety outcome was major bleeding up to 9 days after surgery.
RESULTS:
Primary efficacy endpoint: of 1017 patients randomized, 960 patients were evaluable for safety and 729 patients for efficacy. A dose-related decrease in VTE incidence from YM150 5 to 60 mg (P = 0.0005) and from 5 to 120 mg (P = 0.0002) was found. The VTE incidence was 27.4%, 31.7%, 19.3%, 13.3% and 14.5% for 5, 10, 30, 60 and 120 mg YM150, respectively, and 18.9% for enoxaparin. Primary safety endpoint: there was one major bleed with YM150 (60 mg) and one with enoxaparin.
CONCLUSIONS:
The oral direct FXa inhibitor YM150 demonstrated a significant dose response regarding efficacy. Doses from 30 to 120 mg had comparable efficacy to enoxaparin, without compromising safety regarding major bleeding events