60 research outputs found

    Health-related quality of life in psoriasis: an analysis of Psocare project patients

    Get PDF
    Psoriasis is a common, chronic, immune-mediated skin disorder that may be complicated by psoriatic arthritis in up to one-third of patients. Psoriasis treatments are increasingly effective, yet more expensive, thus requiring rational decision-making on interventional priorities. The ability to perform cost-utility analyses is hindered by the lack of algorithms that allow the inference of utility measures, like QALY, from specific dermatological health-related qualityof- life (HR-QoL) measures (e.g. Dermatology Life Quality Index [DLQI]). This study aimed to assess whether psoriasisrelated HR-QoL data (DLQI) could be used to obtain utility measures for use in economic analyses

    Health-related quality of life in psoriasis: an analysis of Psocare project patients

    Get PDF
    Psoriasis is a common, chronic, immune-mediated skin disorder that may be complicated by psoriatic arthritis in up to one-third of patients. Psoriasis treatments are increasingly effective, yet more expensive, thus requiring rational decision-making on interventional priorities. The ability to perform cost-utility analyses is hindered by the lack of algorithms that allow the inference of utility measures, like QALY, from specific dermatological health-related qualityof- life (HR-QoL) measures (e.g. Dermatology Life Quality Index [DLQI]). This study aimed to assess whether psoriasisrelated HR-QoL data (DLQI) could be used to obtain utility measures for use in economic analyses

    The absolute age of the globular cluster M15 using near-infrared adaptive optics images from PISCES/LBT

    Get PDF
    We present deep near-infrared (NIR) J, Ks photometry of the old, metal-poor Galactic globular cluster M\,15 obtained with images collected with the LUCI1 and PISCES cameras available at the Large Binocular Telescope (LBT). We show how the use of First Light Adaptive Optics system coupled with the (FLAO) PISCES camera allows us to improve the limiting magnitude by ~2 mag in Ks. By analyzing archival HST data, we demonstrate that the quality of the LBT/PISCES color magnitude diagram is fully comparable with analogous space-based data. The smaller field of view is balanced by the shorter exposure time required to reach a similar photometric limit. We investigated the absolute age of M\,15 by means of two methods: i) by determining the age from the position of the main sequence turn-off; and ii) by the magnitude difference between the MSTO and the well-defined knee detected along the faint portion of the MS. We derive consistent values of the absolute age of M15, that is 12.9+-2.6 Gyr and 13.3+-1.1 Gyr, respectively.Comment: 13 pages, 8 figures, ApJ accepte

    Multi-band high resolution spectroscopy rules out the hot Jupiter BD+20 1790b - First data from the GIARPS Commissioning

    Get PDF
    Context. Stellar activity is currently challenging the detection of young planets via the radial velocity (RV) technique. Aims. We attempt to definitively discriminate the nature of the RV variations for the young active K5 star BD+20 1790, for which visible (VIS) RV measurements show divergent results on the existence of a substellar companion. Methods. We compare VIS data with high precision RVs in the near infrared (NIR) range by using the GIANO - B and IGRINS spectrographs. In addition, we present for the first time simultaneous VIS-NIR observations obtained with GIARPS (GIANO - B and HARPS - N) at Telescopio Nazionale Galileo (TNG). Orbital RVs are achromatic, so the RV amplitude does not change at different wavelengths, while stellar activity induces wavelength-dependent RV variations, which are significantly reduced in the NIR range with respect to the VIS. Results. The NIR radial velocity measurements from GIANO - B and IGRINS show an average amplitude of about one quarter with respect to previously published VIS data, as expected when the RV jitter is due to stellar activity. Coeval multi-band photometry surprisingly shows larger amplitudes in the NIR range, explainable with a mixture of cool and hot spots in the same active region. Conclusions. In this work, the claimed massive planet around BD+20 1790 is ruled out by our data. We exploited the crucial role of multi- wavelength spectroscopy when observing young active stars: thanks to facilities like GIARPS that provide simultaneous observations, this method can reach its maximum potential.Comment: 12 pages, 7 figure

    LBT observations of the HR 8799 planetary system: First detection of HR8799e in H band

    Full text link
    We have performed H and Ks band observations of the planetary system around HR 8799 using the new AO system at the Large Binocular Telescope and the PISCES Camera. The excellent instrument performance (Strehl ratios up to 80% in H band) enabled detection the inner planet HR8799e in the H band for the first time. The H and Ks magnitudes of HR8799e are similar to those of planets c and d, with planet e slightly brighter. Therefore, HR8799e is likely slightly more massive than c and d. We also explored possible orbital configurations and their orbital stability. We confirm that the orbits of planets b, c and e are consistent with being circular and coplanar; planet d should have either an orbital eccentricity of about 0.1 or be non-coplanar with respect to b and c. Planet e can not be in circular and coplanar orbit in a 4:2:1 mean motion resonances with c and d, while coplanar and circular orbits are allowed for a 5:2 resonance. The analysis of dynamical stability shows that the system is highly unstable or chaotic when planetary masses of about 5 MJup for b and 7 MJup for the other planets are adopted. Significant regions of dynamical stability for timescales of tens of Myr are found when adopting planetary masses of about 3.5, 5, 5, and 5 Mjup for HR 8799 b, c, d, and e respectively. These masses are below the current estimates based on the stellar age (30 Myr) and theoretical models of substellar objects.Comment: 13 pages, 10 figures, A&A, accepte

    GMP-selected dual and lensed AGNs: selection function and classification based on near-IR colors and resolved spectra from VLT/ERIS, KECK/OSIRIS, and LBT/LUCI

    Full text link
    The Gaia-Multi-Peak (GMP) technique can be used to identify large numbers of dual or lensed AGN candidates at sub-arcsec separation, allowing us to study both multiple SMBHs in the same galaxy and rare, compact lensed systems. The observed samples can be used to test the predictions of the models of SMBH merging once 1) the selection function of the GMP technique is known, and 2) each system has been classified as dual AGN, lensed AGN, or AGN/star alignment. Here we show that the GMP selection is very efficient for separations above 0.15'' when the secondary (fainter) object has magnitude G<20.5. We present the spectroscopic classification of five GMP candidates using VLT/ERIS and Keck/OSIRIS, and compare them with the classifications obtained from: a) the near-IR colors of 7 systems obtained with LBT/LUCI, and b) the analysis of the total, spatially-unresolved spectra. We conclude that colors and integrated spectra can already provide reliable classifications of many systems. Finally, we summarize the confirmed dual AGNs at z>0.5 selected by the GMP technique, and compare this sample with other such systems from the literature, concluding that GMP can provide a large number of confirmed dual AGNs at separations below 7 kpc.Comment: 14 pages,A&A, in pres

    GMP-selected dual and lensed AGNs: Selection function and classification based on near-IR colors and resolved spectra from VLT/ERIS, Keck/OSIRIS, and LBT/LUCI

    Get PDF
    The Gaia Multipeak (GMP) technique can be used to identify large numbers of dual or lensed active galactic nucleus (AGN) candidates at subarcsec separation, allowing us to study both multiple supermassive black holes (SMBHs) in the same galaxy and rare, compact lensed systems. The observed samples can be used to test the predictions of the models of SMBH merging when (1) the selection function of the GMP technique is known, and (2) each system has been classified as a dual AGN, a lensed AGN, or an AGN/star alignment. Here we show that the GMP selection is very efficient for separations above 0:15′′ when the secondary (fainter) object has a magnitude G ≤ 20:5. We present the spectroscopic classification of five GMP candidates using VLT/ERIS and Keck/OSIRIS and compare them with the classifications obtained from (a) the near-IR colors of seven systems obtained with LBT/LUCI, and (b) the analysis of the total spatially unresolved spectra. We conclude that colors and integrated spectra can already provide reliable classifications of many systems. Finally, we summarize the confirmed dual AGNs at z &gt; 0:5 selected by the GMP technique, and compare this sample with other such systems from the literature, concluding that GMP can provide a large number of confirmed dual AGNs at separations below 7 kpc

    IRAK4 gene polymorphism and odontogenic maxillary sinusitis

    Get PDF
    Objectives This study aimed to evaluate whether a specific interleukin-1 receptor-associated kinase-4 (IRAK4) gene polymorphism had any influence on the development of changes in maxillary sinus, particularly in the presence of etiological factors of dental origin.Materials and methods The study population included 153 Portuguese Caucasians that were selected from a database of 504 retrospectively analysed computed tomography (CT) scans. A genetic test was performed, and a model was created through logistic analysis and regression coefficients. The statistical methodologies included were the independent Chi test, Fisher's exact test, binary logistic regression and the receiver operating characteristic (ROC) curve.Results The estimated prevalence of IRAK4 gene polymorphism found in a Portuguese Caucasian population was 26.8 % (CI 95 %) [20.1, 34.7 %]. A model to predict the inflammatory response in the maxillary sinus in the presence etiological factors of dental origin was constructed. This model had the following as variables: previously diagnosed sinusitis, sinus pressure symptoms, cortical bone loss observed on CT, positive genetic test result and radiographic examination that revealed the roots of the teeth communication with the maxillary sinus, which are interpreted as risk factors.Conclusions The constructed model should be considered an initial clinical tool. The area under the ROC curve found, AUC=0.91, revealed that the model correctly predicts the outcome in 91.1 % of cases.info:eu-repo/semantics/publishedVersio

    High Resolution Images of Orbital Motion in the Orion Trapezium Cluster with the LBT Adaptive Optics System

    Full text link
    The new 8.4m LBT adaptive secondary AO system, with its novel pyramid wavefront sensor, was used to produce very high Strehl (75% at 2.16 microns) near infrared narrowband (Br gamma: 2.16 microns and [FeII]: 1.64 microns) images of 47 young (~1 Myr) Orion Trapezium theta1 Ori cluster members. The inner ~41x53" of the cluster was imaged at spatial resolutions of ~0.050" (at 1.64 microns). A combination of high spatial resolution and high S/N yielded relative binary positions to ~0.5 mas accuracies. Including previous speckle data, we analyse a 15 year baseline of high-resolution observations of this cluster. We are now sensitive to relative proper motions of just ~0.3 mas/yr (0.6 km/s at 450 pc) this is a ~7x improvement in orbital velocity accuracy compared to previous efforts. We now detect clear orbital motions in the theta1 Ori B2/B3 system of 4.9+/-0.3 km/s and 7.2+/-0.8 km/s in the theta1 Ori A1/A2 system (with correlations of PA vs. time at >99% confidence). All five members of the theta1 Ori B system appear likely as a gravitationally bound "mini-cluster". The very lowest mass member of the theta1 Ori B system (B4; mass ~0.2 Msun) has, for the first time, a clearly detected motion (at 4.3+/-2.0 km/s; correlation=99.7%) w.r.t B1. However, B4 is most likely in an long-term unstable (non-hierarchical) orbit and may "soon" be ejected from this "mini-cluster". This "ejection" process could play a major role in the formation of low mass stars and brown dwarfs.Comment: 27 pages, 14 figures, accepted for publication by the Astrophysical Journa

    Preliminary safety and efficacy of first-line pertuzumab combined with trastuzumab and taxane therapy for HER2-positive locally recurrent or metastatic breast cancer (PERUSE).

    Get PDF
    BACKGROUND: Pertuzumab combined with trastuzumab and docetaxel is the standard first-line therapy for HER2-positive metastatic breast cancer, based on results from the phase III CLEOPATRA trial. PERUSE was designed to assess the safety and efficacy of investigator-selected taxane with pertuzumab and trastuzumab in this setting. PATIENTS AND METHODS: In the ongoing multicentre single-arm phase IIIb PERUSE study, patients with inoperable HER2-positive advanced breast cancer (locally recurrent/metastatic) (LR/MBC) and no prior systemic therapy for LR/MBC (except endocrine therapy) received docetaxel, paclitaxel or nab-paclitaxel with trastuzumab [8\u2009mg/kg loading dose, then 6\u2009mg/kg every 3\u2009weeks (q3w)] and pertuzumab (840\u2009mg loading dose, then 420\u2009mg q3w) until disease progression or unacceptable toxicity. The primary end point was safety. Secondary end points included overall response rate (ORR) and progression-free survival (PFS). RESULTS: Overall, 1436 patients received at least one treatment dose (initially docetaxel in 775 patients, paclitaxel in 589, nab-paclitaxel in 65; 7 discontinued before starting taxane). Median age was 54\u2009years; 29% had received prior trastuzumab. Median treatment duration was 16\u2009months for pertuzumab and trastuzumab and 4\u2009months for taxane. Compared with docetaxel-containing therapy, paclitaxel-containing therapy was associated with more neuropathy (all-grade peripheral neuropathy 31% versus 16%) but less febrile neutropenia (1% versus 11%) and mucositis (14% versus 25%). At this preliminary analysis (52 months' median follow-up), median PFS was 20.6 [95% confidence interval (CI) 18.9-22.7] months overall (19.6, 23.0 and 18.1\u2009months with docetaxel, paclitaxel and nab-paclitaxel, respectively). ORR was 80% (95% CI 78%-82%) overall (docetaxel 79%, paclitaxel 83%, nab-paclitaxel 77%). CONCLUSIONS: Preliminary findings from PERUSE suggest that the safety and efficacy of first-line pertuzumab, trastuzumab and taxane for HER2-positive LR/MBC are consistent with results from CLEOPATRA. Paclitaxel appears to be a valid alternative taxane backbone to docetaxel, offering similar PFS and ORR with a predictable safety profile. CLINICALTRIALS.GOV: NCT01572038
    corecore