50 research outputs found

    Challenges and opportunities in resuming spirometry services in England post-pandemic with potential to adopt Artificial Intelligence decision support software: a qualitative study

    Get PDF
    Background: Spirometry services to diagnose and monitor lung disease in primary care are restarting post-pandemic in England, identified as a priority in the NHS Long Term Plan, however evidence regarding best practice is limited.Aims: To explore perspectives on spirometry provision in primary care, and the potential for Artificial Intelligence (AI) decision support software to aid quality and interpretation.Design and Setting: Semi-structured interviews with stakeholders in spirometry services in primary care.Methods: Semi-structured interviews were conducted with key stakeholders in spirometry services across England. Participants were recruited by snowball sampling. Interviews explored the pre-pandemic delivery of spirometry, restarting of services and perceptions of the role of AI. Transcripts were analysed thematically.Results: 28 participants (mean [SD], 21.6 [9.4, range 3-40] years’ clinical experience) were interviewed between April and June 2022. Participants included clinicians (n=25) and commissioners (n=3); eight held regional and/or national respiratory network advisory roles. Four themes were identified: 1) Historical challenges in spirometry provision; 2) Inequity in post-pandemic spirometry provision and challenges to restarting spirometry in primary care; 3) Future delivery closer to patients’ homes by appropriately trained staff; 4) The potential for AI to have supportive roles in spirometry.Conclusion: Stakeholders highlighted historic challenges and the damaging effects of the pandemic contributing to inequity in provision of spirometry, which must be addressed. Overall stakeholders were positive about the potential of AI to support clinicians in quality assessment and interpretation of spirometry. However, it was evident that validation of the software must be sufficiently robust for clinicians and healthcare commissioners to have trust in the process

    Comparing performance of primary care clinicians in the interpretation of SPIROmetry with or without Artificial Intelligence Decision support software (SPIRO-AID): a protocol for a randomised controlled trial.

    Get PDF
    INTRODUCTION: Spirometry is a point-of-care lung function test that helps support the diagnosis and monitoring of chronic lung disease. The quality and interpretation accuracy of spirometry is variable in primary care. This study aims to evaluate whether artificial intelligence (AI) decision support software improves the performance of primary care clinicians in the interpretation of spirometry, against reference standard (expert interpretation). METHODS AND ANALYSIS: A parallel, two-group, statistician-blinded, randomised controlled trial of primary care clinicians in the UK, who refer for, or interpret, spirometry. People with specialist training in respiratory medicine to consultant level were excluded. A minimum target of 228 primary care clinician participants will be randomised with a 1:1 allocation to assess fifty de-identified, real-world patient spirometry sessions through an online platform either with (intervention group) or without (control group) AI decision support software report. Outcomes will cover primary care clinicians' spirometry interpretation performance including measures of technical quality assessment, spirometry pattern recognition and diagnostic prediction, compared with reference standard. Clinicians' self-rated confidence in spirometry interpretation will also be evaluated. The primary outcome is the proportion of the 50 spirometry sessions where the participant's preferred diagnosis matches the reference diagnosis. Unpaired t-tests and analysis of covariance will be used to estimate the difference in primary outcome between intervention and control groups. ETHICS AND DISSEMINATION: This study has been reviewed and given favourable opinion by Health Research Authority Wales (reference: 22/HRA/5023). Results will be submitted for publication in peer-reviewed journals, presented at relevant national and international conferences, disseminated through social media, patient and public routes and directly shared with stakeholders. TRIAL REGISTRATION NUMBER: NCT05933694

    Estimation of progression of multi-state chronic disease using the Markov model and prevalence pool concept

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>We propose a simple new method for estimating progression of a chronic disease with multi-state properties by unifying the prevalence pool concept with the Markov process model.</p> <p>Methods</p> <p>Estimation of progression rates in the multi-state model is performed using the E-M algorithm. This approach is applied to data on Type 2 diabetes screening.</p> <p>Results</p> <p>Good convergence of estimations is demonstrated. In contrast to previous Markov models, the major advantage of our proposed method is that integrating the prevalence pool equation (that the numbers entering the prevalence pool is equal to the number leaving it) into the likelihood function not only simplifies the likelihood function but makes estimation of parameters stable.</p> <p>Conclusion</p> <p>This approach may be useful in quantifying the progression of a variety of chronic diseases.</p

    Association of Panton Valentine Leukocidin (PVL) genes with methicillin resistant Staphylococcus aureus (MRSA) in Western Nepal: a matter of concern for community infections (a hospital based prospective study)

    Get PDF
    BACKGROUND: Methicillin resistant Staphylococcus aureus (MRSA) is a major human pathogen associated with nosocomial and community infections. Panton Valentine leukocidin (PVL) is considered one of the important virulence factors of S. aureus responsible for destruction of white blood cells, necrosis and apoptosis and as a marker of community acquired MRSA. This study was aimed to determine the prevalence of PVL genes among MRSA isolates and to check the reliability of PVL as marker of community acquired MRSA isolates from Western Nepal. METHODS: A total of 400 strains of S. aureus were collected from clinical specimens and various units (Operation Theater, Intensive Care Units) of the hospital and 139 of these had been confirmed as MRSA by previous study. Multiplex PCR was used to detect mecA and PVL genes. Clinical data as well as antimicrobial susceptibility data was analyzed and compared among PVL positive and negative MRSA isolates. RESULTS: Out of 139 MRSA isolates, 79 (56.8 %) were PVL positive. The majority of the community acquired MRSA (90.4 %) were PVL positive (Positive predictive value: 94.9 % and negative predictive value: 86.6 %), while PVL was detected only in 4 (7.1 %) hospital associated MRSA strains. None of the MRSA isolates from hospital environment was found positive for the PVL genes. The majority of the PVL positive strains (75.5 %) were isolated from pus samples. Antibiotic resistance among PVL negative MRSA isolates was found higher as compared to PVL positive MRSA. CONCLUSION: Our study showed high prevalence of PVL among community acquired MRSA isolates. Absence of PVL among MRSA isolates from hospital environment indicates its poor association with hospital acquired MRSA and therefore, PVL may be used a marker for community acquired MRSA. This is first study from Nepal, to test PVL among MRSA isolates from hospital environment. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12879-016-1531-1) contains supplementary material, which is available to authorized users

    Genetic variation among species, races, forms and inbred lines of lac insects belonging to the genus Kerria (Homoptera, Tachardiidae)

    Get PDF
    The lac insects (Homoptera: Tachardiidae), belonging to the genus Kerria, are commercially exploited for the production of lac. Kerria lacca is the most commonly used species in India. RAPD markers were used for assessing genetic variation in forty-eight lines of Kerria, especially among geographic races, infrasubspecific forms, cultivated lines, inbred lines, etc., of K. lacca. In the 48 lines studied, the 26 RAPD primers generated 173 loci, showing 97.7% polymorphism. By using neighbor-joining, the dendrogram generated from the similarity matrix resolved the lines into basically two clusters and outgroups. The major cluster, comprising 32 lines, included mainly cultivated lines of the rangeeni form, geographic races and inbred lines of K. lacca. The second cluster consisted of eight lines of K. lacca, seven of the kusmi form and one of the rangeeni from the southern state of Karnataka. The remaining eight lines formed a series of outgroups, this including a group of three yellow mutant lines of K. lacca and other species of the Kerria studied, among others. Color mutants always showed distinctive banding patterns compared to their wild-type counterparts from the same population. This study also adds support to the current status of kusmi and rangeeni, as infraspecific forms of K. lacca

    Abatacept in individuals at high risk of rheumatoid arthritis (APIPPRA): a randomised, double-blind, multicentre, parallel, placebo-controlled, phase 2b clinical trial

    Get PDF
    \ua9 2024 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY 4.0 license. Background: Individuals with serum antibodies to citrullinated protein antigens (ACPA), rheumatoid factor, and symptoms, such as inflammatory joint pain, are at high risk of developing rheumatoid arthritis. In the arthritis prevention in the pre-clinical phase of rheumatoid arthritis with abatacept (APIPPRA) trial, we aimed to evaluate the feasibility, efficacy, and acceptability of treating high risk individuals with the T-cell co-stimulation modulator abatacept. Methods: The APIPPRA study was a randomised, double-blind, multicentre, parallel, placebo-controlled, phase 2b clinical trial done in 28 hospital-based early arthritis clinics in the UK and three in the Netherlands. Participants (aged ≄18 years) at risk of rheumatoid arthritis positive for ACPA and rheumatoid factor with inflammatory joint pain were recruited. Exclusion criteria included previous episodes of clinical synovitis and previous use of corticosteroids or disease-modifying antirheumatic drugs. Participants were randomly assigned (1:1) using a computer-generated permuted block randomisation (block sizes of 2 and 4) stratified by sex, smoking, and country, to 125 mg abatacept subcutaneous injections weekly or placebo for 12 months, and then followed up for 12 months. Masking was achieved by providing four kits (identical in appearance and packaging) with pre-filled syringes with coded labels of abatacept or placebo every 3 months. The primary endpoint was the time to development of clinical synovitis in three or more joints or rheumatoid arthritis according to American College of Rheumatology and European Alliance of Associations for Rheumatology 2010 criteria, whichever was met first. Synovitis was confirmed by ultrasonography. Follow-up was completed on Jan 13, 2021. All participants meeting the intention-to-treat principle were included in the analysis. This trial was registered with EudraCT (2013–003413–18). Findings: Between Dec 22, 2014, and Jan 14, 2019, 280 individuals were evaluated for eligibility and, of 213 participants, 110 were randomly assigned to abatacept and 103 to placebo. During the treatment period, seven (6%) of 110 participants in the abatacept group and 30 (29%) of 103 participants in the placebo group met the primary endpoint. At 24 months, 27 (25%) of 110 participants in the abatacept group had progressed to rheumatoid arthritis, compared with 38 (37%) of 103 in the placebo group. The estimated proportion of participants remaining arthritis-free at 12 months was 92\ub78% (SE 2\ub76) in the abatacept group and 69\ub72% (4\ub77) in the placebo group. Kaplan–Meier arthritis-free survival plots over 24 months favoured abatacept (log-rank test p=0\ub7044). The difference in restricted mean survival time between groups was 53 days (95% CI 28–78; p&lt;0\ub70001) at 12 months and 99 days (95% CI 38–161; p=0\ub70016) at 24 months in favour of abatacept. During treatment, abatacept was associated with improvements in pain scores, functional wellbeing, and quality-of-life measurements, as well as low scores of subclinical synovitis by ultrasonography, compared with placebo. However, the effects were not sustained at 24 months. Seven serious adverse events occurred in the abatacept group and 11 in the placebo group, including one death in each group deemed unrelated to treatment. Interpretation: Therapeutic intervention during the at-risk phase of rheumatoid arthritis is feasible, with acceptable safety profiles. T-cell co-stimulation modulation with abatacept for 12 months reduces progression to rheumatoid arthritis, with evidence of sustained efficacy beyond the treatment period, and with no new safety signals. Funding: Bristol Myers Squibb

    Production and processing of graphene and related materials

    Get PDF
    We present an overview of the main techniques for production and processing of graphene and related materials (GRMs), as well as the key characterization procedures. We adopt a 'hands-on' approach, providing practical details and procedures as derived from literature as well as from the authors' experience, in order to enable the reader to reproduce the results. Section I is devoted to 'bottom up' approaches, whereby individual constituents are pieced together into more complex structures. We consider graphene nanoribbons (GNRs) produced either by solution processing or by on-surface synthesis in ultra high vacuum (UHV), as well carbon nanomembranes (CNM). Production of a variety of GNRs with tailored band gaps and edge shapes is now possible. CNMs can be tuned in terms of porosity, crystallinity and electronic behaviour. Section II covers 'top down' techniques. These rely on breaking down of a layered precursor, in the graphene case usually natural crystals like graphite or artificially synthesized materials, such as highly oriented pyrolythic graphite, monolayers or few layers (FL) flakes. The main focus of this section is on various exfoliation techniques in a liquid media, either intercalation or liquid phase exfoliation (LPE). The choice of precursor, exfoliation method, medium as well as the control of parameters such as time or temperature are crucial. A definite choice of parameters and conditions yields a particular material with specific properties that makes it more suitable for a targeted application. We cover protocols for the graphitic precursors to graphene oxide (GO). This is an important material for a range of applications in biomedicine, energy storage, nanocomposites, etc. Hummers' and modified Hummers' methods are used to make GO that subsequently can be reduced to obtain reduced graphene oxide (RGO) with a variety of strategies. GO flakes are also employed to prepare three-dimensional (3d) low density structures, such as sponges, foams, hydro- or aerogels. The assembly of flakes into 3d structures can provide improved mechanical properties. Aerogels with a highly open structure, with interconnected hierarchical pores, can enhance the accessibility to the whole surface area, as relevant for a number of applications, such as energy storage. The main recipes to yield graphite intercalation compounds (GICs) are also discussed. GICs are suitable precursors for covalent functionalization of graphene, but can also be used for the synthesis of uncharged graphene in solution. Degradation of the molecules intercalated in GICs can be triggered by high temperature treatment or microwave irradiation, creating a gas pressure surge in graphite and exfoliation. Electrochemical exfoliation by applying a voltage in an electrolyte to a graphite electrode can be tuned by varying precursors, electrolytes and potential. Graphite electrodes can be either negatively or positively intercalated to obtain GICs that are subsequently exfoliated. We also discuss the materials that can be amenable to exfoliation, by employing a theoretical data-mining approach. The exfoliation of LMs usually results in a heterogeneous dispersion of flakes with different lateral size and thickness. This is a critical bottleneck for applications, and hinders the full exploitation of GRMs produced by solution processing. The establishment of procedures to control the morphological properties of exfoliated GRMs, which also need to be industrially scalable, is one of the key needs. Section III deals with the processing of flakes. (Ultra)centrifugation techniques have thus far been the most investigated to sort GRMs following ultrasonication, shear mixing, ball milling, microfluidization, and wet-jet milling. It allows sorting by size and thickness. Inks formulated from GRM dispersions can be printed using a number of processes, from inkjet to screen printing. Each technique has specific rheological requirements, as well as geometrical constraints. The solvent choice is critical, not only for the GRM stability, but also in terms of optimizing printing on different substrates, such as glass, Si, plastic, paper, etc, all with different surface energies. Chemical modifications of such substrates is also a key step. Sections IV–VII are devoted to the growth of GRMs on various substrates and their processing after growth to place them on the surface of choice for specific applications. The substrate for graphene growth is a key determinant of the nature and quality of the resultant film. The lattice mismatch between graphene and substrate influences the resulting crystallinity. Growth on insulators, such as SiO2, typically results in films with small crystallites, whereas growth on the close-packed surfaces of metals yields highly crystalline films. Section IV outlines the growth of graphene on SiC substrates. This satisfies the requirements for electronic applications, with well-defined graphene-substrate interface, low trapped impurities and no need for transfer. It also allows graphene structures and devices to be measured directly on the growth substrate. The flatness of the substrate results in graphene with minimal strain and ripples on large areas, allowing spectroscopies and surface science to be performed. We also discuss the surface engineering by intercalation of the resulting graphene, its integration with Si-wafers and the production of nanostructures with the desired shape, with no need for patterning. Section V deals with chemical vapour deposition (CVD) onto various transition metals and on insulators. Growth on Ni results in graphitized polycrystalline films. While the thickness of these films can be optimized by controlling the deposition parameters, such as the type of hydrocarbon precursor and temperature, it is difficult to attain single layer graphene (SLG) across large areas, owing to the simultaneous nucleation/growth and solution/precipitation mechanisms. The differing characteristics of polycrystalline Ni films facilitate the growth of graphitic layers at different rates, resulting in regions with differing numbers of graphitic layers. High-quality films can be grown on Cu. Cu is available in a variety of shapes and forms, such as foils, bulks, foams, thin films on other materials and powders, making it attractive for industrial production of large area graphene films. The push to use CVD graphene in applications has also triggered a research line for the direct growth on insulators. The quality of the resulting films is lower than possible to date on metals, but enough, in terms of transmittance and resistivity, for many applications as described in section V. Transfer technologies are the focus of section VI. CVD synthesis of graphene on metals and bottom up molecular approaches require SLG to be transferred to the final target substrates. To have technological impact, the advances in production of high-quality large-area CVD graphene must be commensurate with those on transfer and placement on the final substrates. This is a prerequisite for most applications, such as touch panels, anticorrosion coatings, transparent electrodes and gas sensors etc. New strategies have improved the transferred graphene quality, making CVD graphene a feasible option for CMOS foundries. Methods based on complete etching of the metal substrate in suitable etchants, typically iron chloride, ammonium persulfate, or hydrogen chloride although reliable, are time- and resource-consuming, with damage to graphene and production of metal and etchant residues. Electrochemical delamination in a low-concentration aqueous solution is an alternative. In this case metallic substrates can be reused. Dry transfer is less detrimental for the SLG quality, enabling a deterministic transfer. There is a large range of layered materials (LMs) beyond graphite. Only few of them have been already exfoliated and fully characterized. Section VII deals with the growth of some of these materials. Amongst them, h-BN, transition metal tri- and di-chalcogenides are of paramount importance. The growth of h-BN is at present considered essential for the development of graphene in (opto) electronic applications, as h-BN is ideal as capping layer or substrate. The interesting optical and electronic properties of TMDs also require the development of scalable methods for their production. Large scale growth using chemical/physical vapour deposition or thermal assisted conversion has been thus far limited to a small set, such as h-BN or some TMDs. Heterostructures could also be directly grown. Section VIII discusses advances in GRM functionalization. A broad range of organic molecules can be anchored to the sp2 basal plane by reductive functionalization. Negatively charged graphene can be prepared in liquid phase (e.g. via intercalation chemistry or electrochemically) and can react with electrophiles. This can be achieved both in dispersion or on substrate. The functional groups of GO can be further derivatized. Graphene can also be noncovalently functionalized, in particular with polycyclic aromatic hydrocarbons that assemble on the sp2 carbon network by π–π stacking. In the liquid phase, this can enhance the colloidal stability of SLG/FLG. Approaches to achieve noncovalent on-substrate functionalization are also discussed, which can chemically dope graphene. Research efforts to derivatize CNMs are also summarized, as well as novel routes to selectively address defect sites. In dispersion, edges are the most dominant defects and can be covalently modified. This enhances colloidal stability without modifying the graphene basal plane. Basal plane point defects can also be modified, passivated and healed in ultra-high vacuum. The decoration of graphene with metal nanoparticles (NPs) has also received considerable attention, as it allows to exploit synergistic effects between NPs and graphene. Decoration can be either achieved chemically or in the gas phase. All LMs, can be functionalized and we summarize emerging approaches to covalently and noncovalently functionalize MoS2 both in the liquid and on substrate. Section IX describes some of the most popular characterization techniques, ranging from optical detection to the measurement of the electronic structure. Microscopies play an important role, although macroscopic techniques are also used for the measurement of the properties of these materials and their devices. Raman spectroscopy is paramount for GRMs, while PL is more adequate for non-graphene LMs (see section IX.2). Liquid based methods result in flakes with different thicknesses and dimensions. The qualification of size and thickness can be achieved using imaging techniques, like scanning probe microscopy (SPM) or transmission electron microscopy (TEM) or spectroscopic techniques. Optical microscopy enables the detection of flakes on suitable surfaces as well as the measurement of optical properties. Characterization of exfoliated materials is essential to improve the GRM metrology for applications and quality control. For grown GRMs, SPM can be used to probe morphological properties, as well as to study growth mechanisms and quality of transfer. More generally, SPM combined with smart measurement protocols in various modes allows one to get obtain information on mechanical properties, surface potential, work functions, electrical properties, or effectiveness of functionalization. Some of the techniques described are suitable for 'in situ' characterization, and can be hosted within the growth chambers. If the diagnosis is made 'ex situ', consideration should be given to the preparation of the samples to avoid contamination. Occasionally cleaning methods have to be used prior to measurement

    Production and processing of graphene and related materials

    Get PDF
    © 2020 The Author(s). We present an overview of the main techniques for production and processing of graphene and related materials (GRMs), as well as the key characterization procedures. We adopt a 'hands-on' approach, providing practical details and procedures as derived from literature as well as from the authors' experience, in order to enable the reader to reproduce the results. Section I is devoted to 'bottom up' approaches, whereby individual constituents are pieced together into more complex structures. We consider graphene nanoribbons (GNRs) produced either by solution processing or by on-surface synthesis in ultra high vacuum (UHV), as well carbon nanomembranes (CNM). Production of a variety of GNRs with tailored band gaps and edge shapes is now possible. CNMs can be tuned in terms of porosity, crystallinity and electronic behaviour. Section II covers 'top down' techniques. These rely on breaking down of a layered precursor, in the graphene case usually natural crystals like graphite or artificially synthesized materials, such as highly oriented pyrolythic graphite, monolayers or few layers (FL) flakes. The main focus of this section is on various exfoliation techniques in a liquid media, either intercalation or liquid phase exfoliation (LPE). The choice of precursor, exfoliation method, medium as well as the control of parameters such as time or temperature are crucial. A definite choice of parameters and conditions yields a particular material with specific properties that makes it more suitable for a targeted application. We cover protocols for the graphitic precursors to graphene oxide (GO). This is an important material for a range of applications in biomedicine, energy storage, nanocomposites, etc. Hummers' and modified Hummers' methods are used to make GO that subsequently can be reduced to obtain reduced graphene oxide (RGO) with a variety of strategies. GO flakes are also employed to prepare three-dimensional (3d) low density structures, such as sponges, foams, hydro- or aerogels. The assembly of flakes into 3d structures can provide improved mechanical properties. Aerogels with a highly open structure, with interconnected hierarchical pores, can enhance the accessibility to the whole surface area, as relevant for a number of applications, such as energy storage. The main recipes to yield graphite intercalation compounds (GICs) are also discussed. GICs are suitable precursors for covalent functionalization of graphene, but can also be used for the synthesis of uncharged graphene in solution. Degradation of the molecules intercalated in GICs can be triggered by high temperature treatment or microwave irradiation, creating a gas pressure surge in graphite and exfoliation. Electrochemical exfoliation by applying a voltage in an electrolyte to a graphite electrode can be tuned by varying precursors, electrolytes and potential. Graphite electrodes can be either negatively or positively intercalated to obtain GICs that are subsequently exfoliated. We also discuss the materials that can be amenable to exfoliation, by employing a theoretical data-mining approach. The exfoliation of LMs usually results in a heterogeneous dispersion of flakes with different lateral size and thickness. This is a critical bottleneck for applications, and hinders the full exploitation of GRMs produced by solution processing. The establishment of procedures to control the morphological properties of exfoliated GRMs, which also need to be industrially scalable, is one of the key needs. Section III deals with the processing of flakes. (Ultra)centrifugation techniques have thus far been the most investigated to sort GRMs following ultrasonication, shear mixing, ball milling, microfluidization, and wet-jet milling. It allows sorting by size and thickness. Inks formulated from GRM dispersions can be printed using a number of processes, from inkjet to screen printing. Each technique has specific rheological requirements, as well as geometrical constraints. The solvent choice is critical, not only for the GRM stability, but also in terms of optimizing printing on different substrates, such as glass, Si, plastic, paper, etc, all with different surface energies. Chemical modifications of such substrates is also a key step. Sections IV-VII are devoted to the growth of GRMs on various substrates and their processing after growth to place them on the surface of choice for specific applications. The substrate for graphene growth is a key determinant of the nature and quality of the resultant film. The lattice mismatch between graphene and substrate influences the resulting crystallinity. Growth on insulators, such as SiO2, typically results in films with small crystallites, whereas growth on the close-packed surfaces of metals yields highly crystalline films. Section IV outlines the growth of graphene on SiC substrates. This satisfies the requirements for electronic applications, with well-defined graphene-substrate interface, low trapped impurities and no need for transfer. It also allows graphene structures and devices to be measured directly on the growth substrate. The flatness of the substrate results in graphene with minimal strain and ripples on large areas, allowing spectroscopies and surface science to be performed. We also discuss the surface engineering by intercalation of the resulting graphene, its integration with Si-wafers and the production of nanostructures with the desired shape, with no need for patterning. Section V deals with chemical vapour deposition (CVD) onto various transition metals and on insulators. Growth on Ni results in graphitized polycrystalline films. While the thickness of these films can be optimized by controlling the deposition parameters, such as the type of hydrocarbon precursor and temperature, it is difficult to attain single layer graphene (SLG) across large areas, owing to the simultaneous nucleation/growth and solution/precipitation mechanisms. The differing characteristics of polycrystalline Ni films facilitate the growth of graphitic layers at different rates, resulting in regions with differing numbers of graphitic layers. High-quality films can be grown on Cu. Cu is available in a variety of shapes and forms, such as foils, bulks, foams, thin films on other materials and powders, making it attractive for industrial production of large area graphene films. The push to use CVD graphene in applications has also triggered a research line for the direct growth on insulators. The quality of the resulting films is lower than possible to date on metals, but enough, in terms of transmittance and resistivity, for many applications as described in section V. Transfer technologies are the focus of section VI. CVD synthesis of graphene on metals and bottom up molecular approaches require SLG to be transferred to the final target substrates. To have technological impact, the advances in production of high-quality large-area CVD graphene must be commensurate with those on transfer and placement on the final substrates. This is a prerequisite for most applications, such as touch panels, anticorrosion coatings, transparent electrodes and gas sensors etc. New strategies have improved the transferred graphene quality, making CVD graphene a feasible option for CMOS foundries. Methods based on complete etching of the metal substrate in suitable etchants, typically iron chloride, ammonium persulfate, or hydrogen chloride although reliable, are time- and resourceconsuming, with damage to graphene and production of metal and etchant residues. Electrochemical delamination in a low-concentration aqueous solution is an alternative. In this case metallic substrates can be reused. Dry transfer is less detrimental for the SLG quality, enabling a deterministic transfer. There is a large range of layered materials (LMs) beyond graphite. Only few of them have been already exfoliated and fully characterized. Section VII deals with the growth of some of these materials. Amongst them, h-BN, transition metal tri- and di-chalcogenides are of paramount importance. The growth of h-BN is at present considered essential for the development of graphene in (opto) electronic applications, as h-BN is ideal as capping layer or substrate. The interesting optical and electronic properties of TMDs also require the development of scalable methods for their production. Large scale growth using chemical/physical vapour deposition or thermal assisted conversion has been thus far limited to a small set, such as h-BN or some TMDs. Heterostructures could also be directly grown
    corecore