498 research outputs found
High-Q trenched aluminum coplanar resonators with an ultrasonic edge microcutting for superconducting quantum devices
Dielectric losses are one of the key factors limiting the coherence of
superconducting qubits. The impact of materials and fabrication steps on
dielectric losses can be evaluated using coplanar waveguide (CPW) microwave
resonators. Here, we report on superconducting CPW microwave resonators with
internal quality factors systematically exceeding 5x106 at high powers and
2x106 (with the best value of 4.4x106) at low power. Such performance is
demonstrated for 100-nm-thick aluminum resonators with 7-10.5 um center trace
on high-resistivity silicon substrates commonly used in quantum Josephson
junction circuits. We investigate internal quality factors of the resonators
with both dry and wet aluminum etching, as well as deep and isotropic reactive
ion etching of silicon substrate. Josephson junction compatible CPW resonators
fabrication process with both airbridges and silicon substrate etching is
proposed. Finally, we demonstrate the effect of airbridges positions and extra
process steps on the overall dielectric losses. The best quality fa ctors are
obtained for the wet etched aluminum resonators and isotropically removed
substrate with the proposed ultrasonic metal edge microcutting.Comment: 6 pages, 2 figure
THE BEAM ENVELOPE CONTROL IN SC LINAC FOR THE PROTON RADIOTHERAPY
Abstract Proton cancer therapy is conventionally based on normal conducting synchrotrons and cyclotrons. The high electrical power consumption and especial devices necessary to energy variation are main problems of such facilities. Superconducting linacs based on short identical independently phased cavities have a seriously progress and it's development allow to propose their using for medical application. High accelerating gradient and small capacity losses nearly 10 -4 W/m are main advantages in advance of normal conducting facilities, the energy variation can be realized by means of RF field amplitude and phase variation in a number of cavities. Besides linac structures are lack of unwieldy magnetic system, simplicity of input and output of particles and high current densities. The parameters choose and the optimization for SC linac structure with energy up to 240 MeV and envelope control will discuss in this paper. The simulation was done using BEAMDULAC-SCL cod
Robust cryogenic matched low-pass coaxial filters for quantum computing applications
Electromagnetic noise is one of the key external factors decreasing
superconducting qubits coherence. Matched coaxial filters can prevent microwave
and IR photons negative influence on superconducting quantum circuits. Here, we
report on design and fabrication route of matched low-pass coaxial filters for
noise-sensitive measurements at milliKelvin temperatures. A robust transmission
coefficient with designed linear absorption (-1dB/GHz) and ultralow reflection
losses less than -20 dB up to 20 GHz is achieved. We present a mathematical
model for evaluating and predicting filters transmission parameters depending
on their dimensions. It is experimentally approved on two filters prototypes
different lengths with compound of Cu powder and Stycast commercial resin
demonstrating excellent matching. The presented design and assembly route are
universal for various compounds and provide high repeatability of geometrical
and microwave characteristics. Finally, we demonstrate three filters with
almost equal reflection and transmission characteristics in the range from 0 to
20 GHz, which is quite useful to control multiple channel superconducting
quantum circuits.Comment: 5 pages, 4 figure
Broadband SNAIL parametric amplifier with microstrip impedance transformer
Josephson parametric amplifiers have emerged as a promising platform for
quantum information processing and squeezed quantum states generation.
Travelling wave and impedance-matched parametric amplifiers provide broad
bandwidth for high-fidelity single-shot readout of multiple qubit
superconducting circuits. Here, we present a quantum-limited 3-wave-mixing
parametric amplifier based on superconducting nonlinear asymmetric inductive
elements (SNAILs), whose useful bandwidth is enhanced with an on-chip
two-section impedance-matching circuit based on microstrip transmission lines.
The amplifier dynamic range is increased using an array of sixty-seven SNAILs
with 268 Josephson junctions, forming a nonlinear quarter-wave resonator.
Operating in a current-pumped mode, we experimentally demonstrate an average
gain of across bandwidth, along with an average saturation
power of , which can go as high as with quantum-limited
noise performance. Moreover, the amplifier can be fabricated using a simple
technology with just a one e-beam lithography step. Its central frequency is
tuned over a several hundred megahertz, which in turn broadens the effective
operational bandwidth to around .Comment: 7 pages, 3 figure
Recommended from our members
STATUS OF ITEP DECABORANE ION SOURCE PROGRAM.
The joint research and development program is continued to develop steady-state ion source of decaborane beam for ion implantation industry. Both Freeman and Bemas ion sources for decaborane ion beam generation were investigated. Decaborane negative ion beam as well as positive ion beam were generated and delivered to the output of mass separator. Experimental results obtained in ITEP are presented
Recommended from our members
Ion Sources for Energy Extremes of Ion Implantation.
For the past four years a joint research and development effort designed to develop steady state, intense ion sources has been in progress with the ultimate goal to develop ion sources and techniques, which meet the two energy extreme range needs of mega-electron-volt and 100's of electron-volt ion implanters. This endeavor has already resulted in record steady state output currents of high charge state of Antimony and Phosphorous ions: P{sup 2+} (8.6 pmA), P{sup 3+} (1.9 pmA), and P{sup 4+} (0.12 pmA) and 16.2, 7.6, 3.3, and 2.2 pmA of Sb{sup 3+} Sb{sup 4+}, Sb{sup 5+}, and Sb{sup 6+} respectively. For low energy ion implantation our efforts involve molecular ions and a novel plasmaless/gasless deceleration method. To date, 1 emA of positive Decaborane ions were extracted at 10 keV and smaller currents of negative Decaborane ions were also extracted. Additionally, Boron current fraction of over 70% was extracted from a Bemas-Calutron ion source, which represents a factor of 3.5 improvement over currently employed ion sources
Search for associated production in collisions at
This report describes a search for associated production of and Higgs
bosons based on data corresponding to an integrated luminosity of collected with the D0 detector at the Fermilab
Tevatron Collider. Events containing a
candidate (with corresponding to or ) are selected in
association with two or three reconstructed jets. One or two of the jets are
required to be consistent with having evolved from a quark. A multivariate
discriminant technique is used to improve the separation of signal and
backgrounds. Expected and observed upper limits are obtained for the product of
the production cross section and branching ratios and reported in terms of
ratios relative to the prediction of the standard model as a function of the
mass of the Higgs boson (). The observed and expected 95% C.L. upper
limits obtained for an assumed are, respectively, factors
of 4.5 and 4.8 larger than the value predicted by the standard model.Comment: 25 pages, 14 figure
A search for charged massive long-lived particles
We report on a search for charged massive long-lived particles (CMLLPs),
based on 5.2 fb of integrated luminosity collected with the D0 detector
at the Fermilab Tevatron collider. We search for events in which one
or more particles are reconstructed as muons but have speed and ionization
energy loss inconsistent with muons produced in beam collisions.
CMLLPs are predicted in several theories of physics beyond the standard model.
We exclude pair-produced long-lived gaugino-like charginos below 267 GeV and
higgsino-like charginos below 217 GeV at 95% C.L., as well as long-lived scalar
top quarks with mass below 285 GeV.Comment: submitted to Phys. Rev. Letter
Precise measurement of the top quark mass in the dilepton channel at D0
We measure the top quark mass (mt) in ppbar collisions at a center of mass
energy of 1.96 TeV using dilepton ttbar->W+bW-bbar->l+nubl-nubarbbar events,
where l denotes an electron, a muon, or a tau that decays leptonically. The
data correspond to an integrated luminosity of 5.4 fb-1 collected with the D0
detector at the Fermilab Tevatron Collider. We obtain mt = 174.0 +- 1.8(stat)
+- 2.4(syst) GeV, which is in agreement with the current world average mt =
173.3 +- 1.1 GeV. This is currently the most precise measurement of mt in the
dilepton channel.Comment: 7 pages, 4 figure
- …