231 research outputs found
Suzaku observation of IGR J16318-4848
We report on the first Suzaku observation of IGR J16318-4848, the most
extreme example of a new group of highly absorbed X-ray binaries that have
recently been discovered by the International Gamma-Ray Astrophysics Laboratory
INTEGRAL. The Suzaku observation was carried out between 2006 August 14 and 17,
with a net exposure time of 97 ks.
The average X-ray spectrum of the source can be well described with a
continuum model typical for neutron stars i.e., a strongly absorbed power law
continuum with a photon index of 0.676(42) and an exponential cutoff at 20.5(6)
keV. The absorbing column is 1.95(3)x10e24 cm-2. Consistent with earlier work,
strong fluorescent emission lines of Fe Kalpha, Fe Kbeta, and Ni Kalpha are
observed. Despite the large absorbing column, no Compton shoulder is seen in
the lines, arguing for a non-spherical and inhomogeneous absorber.
Seen at an average 5-60 keV absorbed flux of 3.4x10e-10 erg cm-2 s-1, the
source exhibits significant variability on timescales of hours.Comment: 5 pages, 5 figures, 1 table. Accepted for publication in A&
Communication and patient safety in gynecology and obstetrics - study protocol of an intervention study.
BACKGROUND: Patient safety is a key target in public health, health services and medicine. Communication between all parties involved in gynecology and obstetrics (clinical staff/professionals, expectant mothers/patients and their partners, close relatives or friends providing social support) should be improved to ensure patient safety, including the avoidance of preventable adverse events (pAEs). Therefore, interventions including an app will be developed in this project through a participatory approach integrating two theoretical models. The interventions will be designed to support participants in their communication with each other and to overcome difficulties in everyday hospital life. The aim is to foster effective communication in order to reduce the frequency of pAEs. If communication is improved, clinical staff should show an increase in work satisfaction and patients should show an increase in patient satisfaction. METHODS: The study will take place in two maternity clinics in Germany. In line with previous studies of complex interventions, it is divided into three interdependent phases. Each phase provides its own methods and data. Phase 1: Needs assessment and a training for staff (n = 140) tested in a pre-experimental study with a pre/post-design. Phase 2: Assessment of communication training for patients and their social support providers (n = 423) in a randomized controlled study. Phase 3: Assessment of an app supporting the communication between staff, patients, and their social support providers (n = 423) in a case-control study. The primary outcome is improvement of communication competencies. A range of other implementation outcomes will also be assessed (i.e. pAEs, patient/treatment satisfaction, work satisfaction, safety culture, training-related outcomes). DISCUSSION: This is the first large intervention study on communication and patient safety in gynecology and obstetrics integrating two theoretical models that have not been applied to this setting. It is expected that the interventions, including the app, will improve communication practice which is linked to a lower probability of pAEs. The app will offer an effective and inexpensive way to promote effective communication independent of users' motivation. Insights gained from this study can inform other patient safety interventions and health policy developments. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT03855735; date of registration: February 27, 2019
Structure of Kα1,2 - And Kβ1,3 -emission x-ray spectra for Se, Y, and Zr
UID/FIS/04559/2020
UID/MULTI/04046/2020
Project No. PTDC/FIS-AQM/31969/20
Grant No. 2017/25/B/ST2/00901The Kα and Kβ x-ray spectra of Se, Y, and Zr were studied experimentally and theoretically in order to obtain information on the Kα1 line asymmetry and the spin doublet in Kβ1,3 diagram lines. Using a high-resolution antiparallel double-crystal x-ray spectrometer, we obtained the line shapes, that is, asymmetry index and natural linewidths. We found that the corrected full width at half maximum of the Kα1 and Kα2 lines as a function of Z is in good agreement with the data in the literature. Furthermore, satellite lines arising from shake-off appear in the low-energy side of the Kα1 and Kα2 lines in Se but, in Y and Zr, it was very difficult to identify the contribution of the shake process to the overall lines. The Kβ1,3 natural linewidth of these elements was also corrected using the appropriate instrumental function for this type of x-ray spectrometer, and the spin doublet energies were obtained from the peak positions. The corrected full width at half maximum (FWHM) of the Kβ1 x-ray lines increases linearly with Z, but this tendency was found to be, in general, not linear for Kβ3 x-ray lines. This behavior may be due to the existence of satellite lines originated from shake processes. Simulated line profiles, obtained using the multiconfiguration Dirac-Fock formalism, accounting for radiative and radiationless transitions and shake-off processes, show a very good agreement with the high-resolution experimental spectra.publishersversionpublishe
Velocity-space sensitivity of the time-of-flight neutron spectrometer at JET
The velocity-space sensitivities of fast-ion diagnostics are often described by so-called weight functions. Recently, we formulated weight functions showing the velocity-space sensitivity of the often dominant beam-target part of neutron energy spectra. These weight functions for neutron emission spectrometry (NES) are independent of the particular NES diagnostic. Here we apply these NES weight functions to the time-of-flight spectrometer TOFOR at JET. By taking the instrumental response function of TOFOR into account, we calculate time-of-flight NES weight functions that enable us to directly determine the velocity-space sensitivity of a given part of a measured time-of-flight spectrum from TOFOR
Relationship of edge localized mode burst times with divertor flux loop signal phase in JET
A phase relationship is identified between sequential edge localized modes (ELMs) occurrence times in a set of H-mode tokamak plasmas to the voltage measured in full flux azimuthal loops in the divertor region. We focus on plasmas in the Joint European Torus where a steady H-mode is sustained over several seconds, during which ELMs are observed in the Be II emission at the divertor. The ELMs analysed arise from intrinsic ELMing, in that there is no deliberate intent to control the ELMing process by external means. We use ELM timings derived from the Be II signal to perform direct time domain analysis of the full flux loop VLD2 and VLD3 signals, which provide a high cadence global measurement proportional to the voltage induced by changes in poloidal magnetic flux. Specifically, we examine how the time interval between pairs of successive ELMs is linked to the time-evolving phase of the full flux loop signals. Each ELM produces a clear early pulse in the full flux loop signals, whose peak time is used to condition our analysis. The arrival time of the following ELM, relative to this pulse, is found to fall into one of two categories: (i) prompt ELMs, which are directly paced by the initial response seen in the flux loop signals; and (ii) all other ELMs, which occur after the initial response of the full flux loop signals has decayed in amplitude. The times at which ELMs in category (ii) occur, relative to the first ELM of the pair, are clustered at times when the instantaneous phase of the full flux loop signal is close to its value at the time of the first ELM
- …