1,859 research outputs found
Large Deployable Reflector Science and Technology Workshop. Volume 3: Systems and Technology Assessment
The results of five technology panels which convened to discuss the Large Deployable Reflector (LDR) are presented. The proposed LDR is a large, ambient-temperature, far infrared/submillimeter telescope designed for space. Panel topics included optics, materials and structures, sensing and control, science instruments, and systems and missions. The telescope requirements, the estimated technology levels, and the areas in which the generic technology work has to be augmented are enumerated
Parametric performance of circumferentially grooved heat pipes with homogeneous and graded-porosity slab wicks at cryogenic temperatures
A recently developed, potentially high-performance nonarterial wick has been extensively tested. This slab wick has an axially varying porosity which can be tailored to match the local stress imposed on the wick. The purpose of the tests was to establish the usefulness of the graded-porosity slab wick at cryogenic temperatures between 110 K and 260 K, with methane and ethane as working fluids. For comparison, a homogeneous (i.e., uniform porosity) slab wick was also tested. The tests included: (1) maximum heat pipe performance as a function of fluid inventory, (2) maximum performance as a function of operating temperature, (3) maximum performance as a function of evaporator elevation, and (4) influence of slab wick orientation on performance. The experimental data was compared with theoretical predictions obtained with the computer program GRADE
Investigation of a single-photon source based on quantum interference
We report on an experimental investigation of a single-photon source based on
a quantum interference effect first demonstrated by Koashi, Matsuoka, and
Hirano [Phys. Rev. A 53, 3621 (1996)]. For certain types of measurement-based
quantum information processing applications this technique may be useful as a
high rate, but random, source of single photons.Comment: Submitted to the New J. Phys. Focus Issue on "Measurement-based
quantum information processing
Time-bin entangled photon holes
The general concept of entangled photon holes is based on a correlated
absence of photon pairs in an otherwise constant optical background. Here we
consider the specialized case when this background is confined to two
well-defined time bins, which allows the formation of time-bin entangled photon
holes. We show that when the typical coherent state background is replaced by a
true single-photon (Fock state) background, the basic time-bin entangled
photon-hole state becomes equivalent to one of the time-bin entangled
photon-pair states. We experimentally demonstrate these ideas using a
parametric down-conversion photon-pair source, linear optics, and
post-selection to violate a Bell inequality with time-bin entangled photon
holes.Comment: 6 pages, 5 figure
Quantum interference by two temporally distinguishable pulses
We report a two-photon interference effect, in which the entangled photon
pairs are generated from two laser pulses well-separated in time. In a single
pump pulse case, interference effects did not occur in our experimental scheme.
However, by introducing a second pump pulse delayed in time, quantum
interference was then observed. The visibility of the interference fringes
shows dependence on the delay time between two laser pulses. The results are
explained in terms of indistinguishability of biphoton amplitudes which
originated from two temporally separated laser pulses.Comment: two-column, 4pages, submitted to PRA, minor change
The Plasmodium berghei Ca(2+)/H(+) exchanger, PbCAX, is essential for tolerance to environmental Ca(2+) during sexual development.
Ca(2+) contributes to a myriad of important cellular processes in all organisms, including the apicomplexans, Plasmodium and Toxoplasma. Due to its varied and essential roles, free Ca(2+) is tightly regulated by complex mechanisms. These mechanisms are therefore of interest as putative drug targets. One pathway in Ca(2+) homeostatic control in apicomplexans uses a Ca(2+)/H(+) exchanger (a member of the cation exchanger family, CAX). The P. falciparum CAX (PfCAX) has recently been characterised in asexual blood stage parasites. To determine the physiological importance of apicomplexan CAXs, tagging and knock-out strategies were undertaken in the genetically tractable T. gondii and P. berghei parasites. In addition, a yeast heterologous expression system was used to study the function of apicomplexan CAXs. Tagging of T. gondii and P. berghei CAXs (TgCAX and PbCAX) under control of their endogenous promoters could not demonstrate measureable expression of either CAX in tachyzoites and asexual blood stages, respectively. These results were consistent with the ability of parasites to tolerate knock-outs of the genes for TgCAX and PbCAX at these developmental stages. In contrast, PbCAX expression was detectable during sexual stages of development in female gametocytes/gametes, zygotes and ookinetes, where it was dispersed in membranous networks within the cytosol (with minimal mitochondrial localisation). Furthermore, genetically disrupted parasites failed to develop further from "round" form zygotes, suggesting that PbCAX is essential for ookinete development and differentiation. This impeded phenotype could be rescued by removal of extracellular Ca(2+). Therefore, PbCAX provides a mechanism for free living parasites to multiply within the ionic microenvironment of the mosquito midgut. Ca(2+) homeostasis mediated by PbCAX is critical and suggests plasmodial CAXs may be targeted in approaches designed to block parasite transmission
All-Optical Switching Demonstration using Two-Photon Absorption and the Classical Zeno Effect
Low-contrast all-optical Zeno switching has been demonstrated in a silicon
nitride microdisk resonator coupled to a hot atomic vapor. The device is based
on the suppression of the field build-up within a microcavity due to
non-degenerate two-photon absorption. This experiment used one beam in a
resonator and one in free-space due to limitations related to device physics.
These results suggest that a similar scheme with both beams resonant in the
cavity would correspond to input power levels near 20 nW.Comment: 4 pages, 5 figure
Validation of the Harvard Lyman-α in situ water vapor instrument: Implications for the mechanisms that control stratospheric water vapor
Building on previously published details of the laboratory calibrations of the Harvard Lyman-α photofragment fluorescence hygrometer (HWV) on the NASA ER-2 and WB-57 aircraft, we describe here the validation process for HWV, which includes laboratory calibrations and intercomparisons with other Harvard water vapor instruments at water vapor mixing ratios from 0 to 10 ppmv, followed by in-flight intercomparisons with the same Harvard hygrometers. The observed agreement exhibited in the laboratory and during intercomparisons helps corroborate the accuracy of HWV. In light of the validated accuracy of HWV, we present and evaluate a series of intercomparisons with satellite and balloon borne water vapor instruments made from the upper troposphere to the lower stratosphere in the tropics and midlatitudes. Whether on the NASA ER-2 or WB-57 aircraft, HWV has consistently measured about 1–1.5 ppmv higher than the balloon-borne NOAA/ESRL/GMD frost point hygrometer (CMDL), the NOAA Cryogenic Frost point Hygrometer (CFH), and the Microwave Limb Sounder (MLS) on the Aura satellite in regions of the atmosphere where water vapor is <10 ppmv. Comparisons in the tropics with the Halogen Occultation Experiment (HALOE) on the Upper Atmosphere Research Satellite show large variable differences near the tropopause that converge to ~10% above 460 K, with HWV higher. Results we show from the Aqua Validation and Intercomparison Experiment (AquaVIT) at the AIDA chamber in Karlsruhe do not reflect the observed in-flight differences. We illustrate that the interpretation of the results of comparisons between modeled and measured representations of the seasonal cycle of water entering the lower tropical stratosphere is dictated by which data set is used
- …