54 research outputs found
Frenkel and charge transfer excitons in C60
We have studied the low energy electronic excitations of C60 using momentum
dependent electron energy-loss spectroscopy in transmission. The momentum
dependent intensity of the gap excitation allows the first direct experimental
determination of the energy of the 1Hg excitation and thus also of the total
width of the multiplet resulting from the gap transition. In addition, we could
elucidate the nature of the following excitations - as either Frenkel or charge
transfer excitons.Comment: RevTEX, 3 Figures, to appear in Phys. Rev.
Is Landscape Context Important for Riparian Conservation? Birds in Grassy Woodland
An important challenge for riparian management is to determine the extent to which landscape context influences the faunal assemblages of riparian habitats. We examined this challenge in the variegated landscapes of southeastern Queensland, Australia where riparian vegetation is surrounded by both extensive grazing and intensive cropping. We investigated whether riparian habitats adjacent to different landuses support similar bird assemblages. Three types of riparian habitat condition were sampled (uncleared ungrazed; uncleared grazed; cleared grazed) in four different land-use contexts (ungrazed woodland; grazed woodland; native pasture; crop) although only six of the twelve possible treatment combinations were available. Eighty percent of bird species responded significantly to changes in both riparian habitat condition and landscape context, while fewer than 50% of species were significantly influenced by landscape context alone. The influence of landscape context on the bird assemblage increased as the surrounding land use became more intensive (e.g. woodland to native pasture to crop). Riparian zones have been shown to have consistently high biodiversity values relative to their extent. These findings suggest it is not enough to conserve riparian habitats alone, conservation and restoration plans must also take into consideration landscape context, particularly when that context is intensively used land
The Creation and Physiological Relevance of Divergent Hydroxylation Patterns in the Flavonoid Pathway
Flavonoids and biochemically-related chalcones are important secondary metabolites, which are ubiquitously present in plants and therefore also in human food. They fulfill a broad range of physiological functions in planta and there are numerous reports about their physiological relevance for humans. Flavonoids have in common a basic C6-C3-C6 skeleton structure consisting of two aromatic rings (A and B) and a heterocyclic ring (C) containing one oxygen atom, whereas chalcones, as the intermediates in the formation of flavonoids, have not yet established the heterocyclic C-ring. Flavonoids are grouped into eight different classes, according to the oxidative status of the C-ring. The large number of divergent chalcones and flavonoid structures is from the extensive modification of the basic molecules. The hydroxylation pattern influences physiological properties such as light absorption and antioxidative activity, which is the base for many beneficial health effects of flavonoids. In some cases antiinfective properties are also effected
Evaluating and Minimizing Distributed Cavity Phase Errors in Atomic Clocks
We perform 3D finite element calculations of the fields in microwave cavities
and analyze the distributed cavity phase errors of atomic clocks that they
produce. The fields of cylindrical cavities are treated as an azimuthal Fourier
series. Each of the lowest components produces clock errors with unique
characteristics that must be assessed to establish a clock's accuracy. We
describe the errors and how to evaluate them. We prove that sharp structures in
the cavity do not produce large frequency errors, even at moderately high
powers, provided the atomic density varies slowly. We model the amplitude and
phase imbalances of the feeds. For larger couplings, these can lead to
increased phase errors. We show that phase imbalances produce a novel
distributed cavity phase error that depends on the cavity detuning. We also
design improved cavities by optimizing the geometry and tuning the mode
spectrum so that there are negligible phase variations, allowing this source of
systematic error to be dramatically reduced.Comment: To appear in Metrologi
Rationale and design of the PeriOperative ISchemic Evaluation-3 (POISE-3): a randomized controlled trial evaluating tranexamic acid and a strategy to minimize hypotension in noncardiac surgery
Background
For patients undergoing noncardiac surgery, bleeding and hypotension are frequent and associated with increased mortality and cardiovascular complications. Tranexamic acid (TXA) is an antifibrinolytic agent with the potential to reduce surgical bleeding; however, there is uncertainty about its efficacy and safety in noncardiac surgery. Although usual perioperative care is commonly consistent with a hypertension-avoidance strategy (i.e., most patients continue their antihypertensive medications throughout the perioperative period and intraoperative mean arterial pressures of 60 mmHg are commonly accepted), a hypotension-avoidance strategy may improve perioperative outcomes.
Methods
The PeriOperative Ischemic Evaluation (POISE)-3 Trial is a large international randomized controlled trial designed to determine if TXA is superior to placebo for the composite outcome of life-threatening, major, and critical organ bleeding, and non-inferior to placebo for the occurrence of major arterial and venous thrombotic events, at 30 days after randomization. Using a partial factorial design, POISE-3 will additionally determine the effect of a hypotension-avoidance strategy versus a hypertension-avoidance strategy on the risk of major cardiovascular events, at 30 days after randomization. The target sample size is 10,000 participants. Patients ≥45 years of age undergoing noncardiac surgery, with or at risk of cardiovascular and bleeding complications, are randomized to receive a TXA 1 g intravenous bolus or matching placebo at the start and at the end of surgery. Patients, health care providers, data collectors, outcome adjudicators, and investigators are blinded to the treatment allocation. Patients on ≥ 1 chronic antihypertensive medication are also randomized to either of the two blood pressure management strategies, which differ in the management of patient antihypertensive medications on the morning of surgery and on the first 2 days after surgery, and in the target mean arterial pressure during surgery. Outcome adjudicators are blinded to the blood pressure treatment allocation. Patients are followed up at 30 days and 1 year after randomization.
Discussion
Bleeding and hypotension in noncardiac surgery are common and have a substantial impact on patient prognosis. The POISE-3 trial will evaluate two interventions to determine their impact on bleeding, cardiovascular complications, and mortality.
Trial registration
ClinicalTrials.gov
NCT03505723. Registered on 23 April 2018
A new strategy to count and sort neutrophil‐derived extracellular vesicles: Validation in infectious disorders
International audienceNewly recognized polymorphonuclear neutrophil (PMNs) functions include the ability to release subcellular mediators such as neutrophil-derived extracellular vesicles (NDEVs) involved in immune and thrombo-inflammatory responses. Elevation of their plasmatic level has been reported in a variety of infectious and cardiovascular disorders, but the clinical use of this potential biomarker is hampered by methodological issues. Although flow cytometry (FCM) is currently used to detect NDEVs in the plasma of patients, an extensive characterization of NDEVs has never been done. Moreover, their detection remains challenging because of their small size and low antigen density. Therefore, the objective of the present study was first to establish a surface antigenic signature of NDEVs detectable by FCM and therefore to improve their detection in biological fluids by developing a strategy allowing to overcome their low fluorescent signal and reduce the background noise. By testing a large panel of 54 antibody specificities already reported to be positive on PMNs, we identified a profile of 15 membrane protein markers, including 4 (CD157, CD24, CD65 and CD66c) never described on NDEVs. Among them, CD15, CD66b and CD66c were identified as the most sensitive and specific markers to detect NDEVs by FCM. Using this antigenic signature, we developed a new strategy combining the three best antibodies in a cocktail and reducing the background noise by size exclusion chromatography (SEC). This strategy allowed a significant improvement in NDEVs enumeration in plasma from sepsis patients and made it feasible to efficiently sort NDEVs from COVID-19 patients. Altogether, this work opens the door to a more valuable measurement of NDEVs as a potential biomarker in clinical practice. A similar strategy could also be applied to improve detection by FCM of other rare subpopulations of EVs generated by tissues with limited access, such as vascular endothelium, cancer cells or placenta
- …