32 research outputs found
Effects of chin advancement surgery in hyoid bone and tongue positions and in the dimension of the oropharynx
INTRODUCTION: Advancement genioplasty has been increasingly indicated for the correction of anterior mandibular deficiency as it balances the patient's profile and generates functional changes. OBJECTIVE: Thus, the aim of this study was to assess the effects of advancement genioplasty in the oropharyngeal size and in the position of the hyoid bone and tongue. METHODS: The sample comprised 22 lateral cephalometric radiographs of 11 individuals who had undergone advancement genioplasty alone. Eleven of these radiographs depicted the immediate preoperative period (T0) and the other 11 the postoperative period after at least four months (T1). The radiographs were scanned and exported to the Radiocef Studio 2.0® software (Radio Memory Ltda., Belo Horizonte, MG, Brazil). The landmarks were then identified and automatically measured by the program. RESULTS: The results showed statistically significant differences between the horizontal position of the hyoid bone and tongue and in the oropharyngeal size. The hyoid bone and tongue were repositioned anteriorly after surgery (p = 0.01), thereby increasing the dimension of the oropharyngeal airspace (p = 0.01). CONCLUSIONS: The oropharyngeal dimension increased as the tongue base and hyoid bone were repositioned more anteriorlyINTRODUÇÃO: a cirurgia de avanço de mento isolado tem sido cada vez mais indicada para a correção de deficiência anterior da mandíbula, harmonizando o perfil e gerando alterações funcionais. OBJETIVO: essa pesquisa teve a finalidade de avaliar os efeitos da cirurgia de avanço de mento no tamanho da orofaringe e nas posições do osso hioide e da língua. MÉTODOS: a amostra constou de 22 radiografias cefalométricas de perfil de 11 indivíduos que se submeteram à cirurgia de mentoplastia de avanço isolada. Dessas radiografias, 11 retratavam o período imediatamente pré-cirúrgico (T0) e 11 o pós-cirúrgico de, pelo menos, quatro meses (T1). As radiografias foram digitalizadas e transferidas para o programa Radiocef Studio 2.0, por meio do qual foram feitas as medições entre os pontos demarcados. RESULTADOS: verificaram-se diferenças estatisticamente significativas entre T0 e T1 quanto à posição do osso hioide e da língua no sentido horizontal e ao tamanho da orofaringe. O osso hioide se apresentou posicionado mais anterior em T1 (p = 0,01), assim como a língua, aumentando o tamanho da orofaringe (p = 0,01). CONCLUSÃO: houve aumento do espaço aéreo da orofaringe com o posicionamento mais anterior da base da língua, bem como a reposição do osso hioide anteriormente.646
Stafne's Defect with Buccal Cortical Expansion: A Case Report
A rare case of Stafne's bone cavity, type III-G, is reported in a 49-year-old male patient who had been referred to a private clinic for a routine evaluation. The final diagnosis was based on computed tomography. Scintigraphy played a fundamental role in determining the most likely etiology
Querubismo: revisão de literatura
This review aimed at reporting on cherubism, a hereditary form of benign fibro-osseous lesion thought to be inherited as an autosomal dominant trait with a great deal of variability in its expression. Bone lesions begin in early childhood as multiple litic areas of characteristic expansile slow-growing development that lead to severe facial deformity. As the patient reaches puberty the lesions stabilize but the disfigured appearance (characteristic cherubistic facies) jeopardizes the patient's social relationship. Considering the critical role played by image-based examinations where pathological anatomy is inconclusive, we have proposed, as part of the diagnostic approach, taking first the panoramic radiograph and finally the CT as definitive examination. The appropriateness of including the craniofacial fibrous dysplasia in the differential diagnosis is discussed, with emphasis on the clinical and image differences between the conditions.O querubismo é um distúrbio genético que exibe um padrão de hereditariedade autossômica dominante. Sua manifestação ocorre na infância, com múltiplas lesões osteolíticas que resultam em assimetrias faciais grotescas, comprometedoras da integração social de seus portadores. Diferentemente da maior parte das patologias, as análises histológicas das lesões do querubismo são inconclusivas e seu diagnóstico depende do papel decisivo dos exames por imagem. Pretendemos abordar, em caráter revisional, as peculiaridades clínicas, radiográficas e histológicas do querubismo, bem como propor um protocolo de diagnóstico por imagem, com o objetivo de agregar subsídios à conduta diagnóstica a ser adotada. A pertinácia da inclusão da displasia fibrosa crânio-facial no diagnóstico diferencial é discutida, realçando-se as diferenças clínico-imagenológicas entre as condições
Determination of zygomatic implants' length based on computed tomography-establishment of a protocol
Orientador: Paulo Sergio Flores CamposTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de PiracicabaResumo: As fixações zigomáticas são uma alternativa aos enxertos ósseos na reabilitação de maxilas severamente atróficas. Os implantes zigomáticos possuem comprimento três a quatro vezes maior que os implantes convencionais e sua colocação requer muita habilidade e precisão cirúrgica, já que sua trajetória passa pelo interior do seio maxilar e seu ponto de travamento é no corpo do osso zigomático. Desvios do ângulo de inserção e erros de estimativa do comprimento do implante colocam em risco estruturas tão nobres quanto a órbita. O objetivo no presente estudo foi estabelecer e validar um protocolo de exame por tomografia computadorizada que permitisse ao radiologista estimar o comprimento do implante, tornando o procedimento cirúrgico mais previsível e seguro, com o mínimo de exposição do paciente à radiação. Foram utilizados dez crânios humanos secos com maxilas edêntulas e processos alveolares completamente reabsorvidos. Cortes tomográficos paracoronais foram executados e os comprimentos e ângulos horizontais de inserção foram estimados. Em seguida, os espécimes foram submetidos a um procedimento cirúrgico para colocação de implantes zigomáticos (n=20) e conseqüente determinação dos comprimentos real e clínico dos sítios de implante. As médias dos comprimentos tomográfico (CTC), clínico (CCLIN) e real (CREAL) foram: 45,73 ±4,82mm, 42,63 ±4,33mm e 44,73 ±4,53mm, respectivamente. O teste t de Student não revelou diferença estatisticamente significante entre as médias de CREAL e CTC (P=0,1532), ao passo que as médias de CREAL e CCLIN foram estatisticamente diferentes entre si (P<0,0001). O estudo de correlação (Coeficiente de Pearson) revelou que as variáveis analisadas correlacionavam-se significativamente entre si, de forma direta. O protocolo proposto mostrou-se preciso e eficaz na determinação do comprimento de implantes zigomáticos, o que garante ao paciente uma exposição à radiação relativamente baixa, em função da pequena quantidade de cortes tomográficos utilizadaAbstract: Zygomatic fixations offer an alternative to bone grafts in the rehabilitation of severely atrophic maxillas. Zygomatic implants are three to four times longer than conventional implants, and their positioning requires extreme surgical precision and skill, since they must be inserted in the maxillary sinus and their locking point is situated in the body of the zygomatic bone. Deviations in the angle of insertion and miscalculated estimates of the length of the implants may pose a risk to such important structures as the orbit. The present study aimed to establish and validate a testing protocol based on computed tomography that would allow radiologists to better estimate the length of the implants, making the surgical procedure more predictable and safer, and minimizing the patients¿ exposure to radiation. Ten dry edentulous human skulls with completely reabsorbed alveolar processes were used. Tomographic paracoronal images were obtained, and the lengths and horizontal angles of insertion were estimated. Next, the specimens underwent a surgical procedure for insertion of zygomatic implants (n=20) and determination of both actual and clinical lengths of the implants¿ locations. The tomographic, clinical and actual average lengths obtained were 45.73 ±4.82mm, 42.63 ±4.33mm, and 44.73 ±4.53mm, respectively. While Student¿s t-test did not reveal any statistically significant difference between the actual and the tomographic average lengths (P=0.1532), the actual and the clinical average lengths were statistically different (P<0.0001). The correlation study (Pearson¿s coefficient) revealed a significant and direct correlation among the analyzed variables. The proposed protocol proved to be not only precise but also efficient in determining the length of zygomatic implants, ensuring relatively low exposure of patients to radiation due to the small amount of tomographic scans needed.DoutoradoRadiologia OdontologicaDoutor em Radiologia Odontológic
SECAGEM EM CAMADA DELGADA DA FIBRA RESIDUAL DO MARACUJÁ
Estudou-se a secagem em camada delgada do resíduo da industrialização do suco de maracujá (Passiflora edulis), em diferentes condições de temperatura (50 a 70°C) e velocidade do ar de secagem (2,0 a 3,0 m/s). Foram obtidas isotermas de adsorção e dessorção de umidade a 25 e 40°C, visando avaliar o comportamento higroscópico do produto. Avaliou-se a aplicabilidade das equações de Kuhn, Handerson, Oswin, Halsey, Smith, GAB e BET na predição dos dados de sorção. A adsorção indicou que o produto estará microbiologicamente estável (a w < 0,6) quando apresentar umidade inferior a 18 g/100 g (b.s). A monocamada indicou que o resíduo não deve ser seco a umidades inferiores a 7,4 g H2O/100 g (b.s). para evitar desperdício de energia. Os calores de dessorção indicaram que a maior parte da água adsorvida no produto está combinada aos solutos. As equações de Kuhn, Oswin, Halsey, GAB e BET podem ser utilizadas na predição das isotermas de sorção de umidade do produto
Revista de Ciências Médicas e Biológicas
O presente trabalho teve como objetivo analisar dados epidemiológicos de dentes supranumerários diagnosticados por
meio de radiografias panorâmicas. Foram avaliadas 1475 radiografias panorâmicas e verificada a prevalência de gênero,
idade do paciente, relação de acometimento maxila–mandíbula e localização dos supranumerários. Constatou-se a
prevalência de dentes supranumerários em aproximadamente 3,7% da amostra, com maior ocorrência no gênero feminino,
predominância na região de pré-molares inferiores, seguida da região de molares superiores e da região de pré-maxila.
Pôde-se inferir, com os resultados obtidos, que a ocorrência de dentes supranumerários representa uma anormalidade
relativamente incomum, com predominância na maxila.Salvado
Levantamento das anomalias dentárias de número (supranumerários) em radiografias panorâmicas de um serviço de documentação odontológica da cidade do Salvador –Bahia
O presente trabalho teve como objetivo analisar dados epidemiológicos de dentes supranumerários diagnosticados por meio de radiografias panorâmicas. Foram avaliadas 1475 radiografias panorâmicas e verificada a prevalência de gênero, idade do paciente, relação de acometimento maxila–mandíbula e localização dos supranumerários. Constatou-se a prevalência de dentes supranumerários em aproximadamente 3,7% da amostra, com maior ocorrência no gênero feminino, predominância na região de pré-molares inferiores, seguida da região de molares superiores e da região de pré-maxila. Pôde-se inferir, com os resultados obtidos, que a ocorrência de dentes supranumerários representa uma anormalidade relativamente incomum, com predominância na maxila
Revista Dental Press de Ortodontia e Ortopedia Facial
P. 95-106,set./outOBJETIVO: avaliar a efetividade de métodos de diagnóstico por imagem utilizados na localização vertical de sítios eleitos para inserção de mini-implantes.
METODOLOGIA: a amostra foi composta de quatro pacientes, nos quais foram estabelecidos 32 sítios inter-radiculares, na região posterior, para instalação de mini-implantes, sítios estes representados por orifícios preenchidos com guta-percha em moldeiras de acetato (PCg - ponto de contato das coroas dentárias na moldeira de acetato; PIg - ponto de inserção do mini-implante na moldeira de acetato). Foram feitas radiografias periapicais, interproximais e tomografias computadorizadas de feixe cônico, com as moldeiras posicionadas em boca, sendo considerados os seguintes pontos: PC - imagem radiodensa do ponto PCg; PI - imagem radiodensa do ponto PIg; PCx - ponto de contato entre as coroas dentárias, determinado sobre a radiografia. Medidas verticais utilizadas: padrão-ouro - de PCg a PIg; medida 1 - de PC a PI; e medida 2 - de PCx a PI. As medidas foram comparadas através de análise descritiva e do teste t de Student.
RESULTADOS: para a medida 1, foi observada diferença estatisticamente significante, em relação ao padrão-ouro, em 4,1%, 25% e 100% das medidas avaliadas nas tomografias computadorizadas, radiografias interproximais e periapicais, respectivamente. Para a medida 2, foi observada diferença estatisticamente significante, em relação ao padrão-ouro, em 4,1%, 56,2% e 100% das medidas avaliadas nas tomografias computadorizadas, radiografias interproximais e periapicais, respectivamente
CONCLUSÕES: a tomografia computadorizada de feixe cônico foi o exame mais preciso na avaliação da posição vertical dos sítios eleitos para instalação de mini-implantes; a radiografia interproximal pode, com reserva, ser utilizada; a radiografia periapical apresentou resultados insatisfatórios, sendo contra-indicada para este fim.Maring