98 research outputs found

    Effect of Hypoxia-Induced Micro-RNAs Expression on Oncogenesis

    Get PDF
    MicroRNAs (miRNAs) are small non-coding RNAs that negatively regulate gene expression at the post-transcriptional level. An aberrant regulation of gene expression by miRNAs is associated with numerous diseases, including cancer. MiRNAs expression can be influenced by various stimuli, among which hypoxia; however, the effects of different types of continuous hypoxia (moderate or marked) on miRNAs are still poorly studied. Lately, some hypoxia-inducible miRNAs (HRMs, hypoxia-regulated miRNAs) have been identified. These HRMs are often activated in different types of cancers, suggesting their role in tumorigenesis. The aim of this study was to evaluate changes in miRNAs expression both in moderate continuous hypoxia and marked continuous hypoxia to better understand the possible relationship between hypoxia, miRNAs, and colorectal cancer. We used RT-PCR to detect the miRNAs expression in colorectal cancer cell lines in conditions of moderate and marked continuous hypoxia. The expression of miRNAs was analyzed using a two-way ANOVA test to compare the differential expression of miRNAs among groups. The levels of almost all analyzed miRNAs (miR-21, miR-23b, miR-26a, miR-27b, and miR-145) were greater in moderate hypoxia versus marked hypoxia, except for miR-23b and miR-21. This study identified a series of miRNAs involved in the response to different types of continuous hypoxia (moderate and marked), highlighting that they play a role in the development of cancer. To date, there are no other studies that demonstrate how these two types of continuous hypoxia could be able to activate different molecular pathways that lead to a different expression of specific miRNAs involved in tumorigenesis

    Comparison between First- and Second-Generation Cryoballoon for Paroxysmal Atrial Fibrillation Ablation

    Get PDF
    Introduction. Cryoballoon (CB) ablation has emerged as a novel treatment for pulmonary vein isolation (PVI) for patients with paroxysmal atrial fibrillation (PAF). The second-generation Arctic Front Advance (ADV) was redesigned with technical modifications aiming at procedural and outcome improvements. We aimed to compare the efficacy of the two different technologies over a long-term follow-up. Methods. A total of 120 patients with PAF were enrolled. Sixty patients underwent PVI using the first-generation CB and 60 patients with the ADV catheter. All patients were evaluated over a follow-up period of 2 years. Results. There were no significant differences between the two groups of patients. Procedures performed with the first-generation CB showed longer fluoroscopy time (36.3±16.8 versus 14.2±13.5 min, resp.; p=0.00016) and longer procedure times as well (153.1±32 versus 102±24.8 min, resp.; p=0.019). The overall long-term success was significantly different between the two groups (68.3 versus 86.7%, resp.; p=0.017). No differences were found in the lesion areas of left and right PV between the two groups (resp., p=0.61 and 0.57). There were no significant differences in procedural-related complications. Conclusion. The ADV catheter compared to the first-generation balloon allows obtaining a significantly higher success rate after a single PVI procedure during the long-term follow-up. Fluoroscopy and procedural times were significantly shortened using the ADV catheter

    Impact of CT Scan Phenotypes in Clinical Manifestations, Management and Outcomes of Hospitalised Patients with COVID-19

    Get PDF
    COVID-19 is such a heterogeneous disease that a one-size-fits-all approach is not recommended, so the management of patients has been based on their clinical and laboratory characteristics. We therefore investigated possible homogeneous groups presenting similar features of lung involvement based on chest CT and laboratory results. We designed a study to identify a possible correlation between CT scan phenotypes, laboratory exams, and clinical outcomes. We retrospectively analysed 120 adult patients with COVID-19 5who underwent chest CT scan during hospitalisation, between March and December 2020 at our COVID-19 Hospital in two different wards: Respiratory Intensive Care Unit (RICU) and Intensive Care Unit (ICU). The analysis of CT scans resulted in the identification of three radiological phenotypes by two blinded pulmonologists (Cohen's κ = 0.9 for Phenotype 1, 0.9 for Phenotype 2 and 0.89 for Phenotype 3), in accordance with what previously described by Robba et al. “Phenotype 1” (PH1) is characterised by modest interstitial oedema with presentation on chest CT of diffuse ground glass opacities (GGO). “Phenotype 2” (PH2) shows predominant consolidation at lung lobes. “Phenotype 3” (PH3) shows a typical CT pattern of moderate-to-severe ARDS, with alveolar oedema. Based on our results, we could hypothesise that phenotype 2 shows a different trend from all the others and would seem to be more related to a coagulopathy, although we cannot exclude the hypothesis that one phenotype evolves from the other. Further studies might focus on the predictive role of D-dimer, and its cut-offs, in delineating the PH2 patients, that could require an early CT scan to avoid excessive pressure support and finally prevent VILI. To further understand the exact basis of the different CT scan phenotype, a longer longitudinal analysis of clinical and laboratory features (e.g., timing of weaning, pressures and FiO2 delivered) in each phenotype and a comparison among them is needed

    Biomarkers of myocardial injury with different energy sources for atrial fibrillation catheter ablation

    Get PDF
    Background: Our study aims to compare acute myocardial injury biomarker rise after atrial fibrillation ablation performed with different technologies.Methods and Results: One hundred and ten patients were treated with pulmonary vein isolation with 4 different technologies: open-irrigated tip radiofrequency (RF) catheter in35 patients (Group A), cryoballoon in 35 patients (Group B), visually guided laser balloon in 20 patients (Group C), open-irrigated tip RF catheter with contact-force-sensing technology in 20 patients (Group D). Post-procedure samples of cardiac troponin I (cTnI) and creatinine kinase-MB (CK-MB) were collected at 19 ± 3 h and 43 ± 3 h after ablation. At the first postprocedural sample, cTnI and CK-MB levels were found elevated in all 110 patients with a median value of 2.11 ng/mL and 8.95 ng/mL, respectively. Group B showed cTnI levels increased (median 5.96 ng/mL) compared to other groups (median Group A: 1.72 ng/mL, Group C: 1.54 ng/mL, Group D: 2.0 ng/mL; p < 0.001). Also CK-MB levels resulted higher in cryoablation (median 26.4 ng/mL) compared to other groups (median Group A: 6.40 ng/mL, Group C: 7.15 ng/mL, Group D: 6.50 ng/mL; p < 0.001). No significant association was observed between biomarker levels and recurrences of atrial fibrillation after a mean follow-up of 369 ± 196 days.Conclusions: Highest markers for myocardial injury were observed in the cryoballoon group. It is possible that a longer delivery energy duration and other factors affecting lesion size resulted in higher amount of cardiac injury in cryoablation. The higher levels of cardiac biomarkers did not translate into a better outcome and its physiologic significance is unknown.

    Endo-Epicardial Homogenization of the Scar Versus Limited Substrate Ablation for the Treatment of Electrical Storms in Patients With Ischemic Cardiomyopathy

    Get PDF
    ObjectivesThis study investigated the impact on recurrences of 2 different substrate approaches for the treatment of these arrhythmias.BackgroundCatheter ablation of electrical storms (ES) for ventricular arrhythmias (VAs) has shown moderate long-term efficacy in patients with ischemic cardiomyopathy.MethodsNinety-two consecutive patients (81% male, age 62 ± 13 years) with ischemic cardiomyopathy and ES underwent catheter ablation. Patients were treated either by confining the radiofrequency lesions to the endocardial surface with limited substrate ablation (Group 1, n = 49) or underwent endocardial and epicardial ablation of abnormal potentials within the scar (homogenization of the scar, Group 2, n = 43). Epicardial access was obtained in all Group 2 patients, whereas epicardial ablation was performed in 33% (14) of these patients.ResultsMean ejection fraction was 27 ± 5. During a mean follow-up of 25 ± 10 months, the VAs recurrence rate of any ventricular tachycardia (VTs) was 47% (23 of 49 patients) in Group 1 and 19% (8 of 43 patients) in Group 2 (log-rank p = 0.006). One patient in Group 1 and 1 patient in Group 2 died at follow-up for noncardiac reasons.ConclusionsOur study demonstrates that ablation using endo-epicardial homogenization of the scar significantly increases freedom from VAs in ischemic cardiomyopathy patients

    Comparison between First-and Second-Generation Cryoballoon for Paroxysmal Atrial Fibrillation Ablation

    Get PDF
    Introduction. Cryoballoon (CB) ablation has emerged as a novel treatment for pulmonary vein isolation (PVI) for patients with paroxysmal atrial fibrillation (PAF). The second-generation Arctic Front Advance (ADV) was redesigned with technical modifications aiming at procedural and outcome improvements. We aimed to compare the efficacy of the two different technologies over a long-term follow-up. Methods. A total of 120 patients with PAF were enrolled. Sixty patients underwent PVI using the firstgeneration CB and 60 patients with the ADV catheter. All patients were evaluated over a follow-up period of 2 years. Results. There were no significant differences between the two groups of patients. Procedures performed with the first-generation CB showed longer fluoroscopy time (36.3 ± 16.8 versus 14.2 ± 13.5 min, resp.; = 0.00016) and longer procedure times as well (153.1 ± 32 versus 102±24.8 min, resp.; = 0.019). The overall long-term success was significantly different between the two groups (68.3 versus 86.7%, resp.; = 0.017). No differences were found in the lesion areas of left and right PV between the two groups (resp., = 0.61 and 0.57). There were no significant differences in procedural-related complications. Conclusion. The ADV catheter compared to the first-generation balloon allows obtaining a significantly higher success rate after a single PVI procedure during the long-term follow-up. Fluoroscopy and procedural times were significantly shortened using the ADV catheter
    corecore