114 research outputs found

    Clinical characteristics and outcome of patients with autoimmune hemolytic anemia (AIHA) uniformly defined as primary by a diagnostic work-up

    Get PDF
    Primary autoimmune hemolytic anemia (P-AIHA) is a relatively uncommon and hetereogeneous disease characterized by the destruction of red blood cells due to anti-erythrocyte autoantibodies (AeAbs) in the absence of an associated disease [1–3]. Secondary AHIA is frequently associated with lymphoproliferative diseases (LD) in particular, chronic lymphocytic leukemia, aggressive or indolent lymphomas, autoimmune disorders, malignancies other than lymphoid, and infections [1,2,4]. On the hypothetical assumption that in a significant proportion of cases defined as P-AIHA the clinical heterogeneity could be due to an ignored associated disease, we retrospectively analyzed the clinical characteristics and outcome of patients with a diagnosis of P-AIHA based on a diagnostic work-up aimed at excluding or identifying an associated disease. ..

    Transmission through graphene of electrons in the 30 – 900 eV range

    Get PDF
    Here, we report on accurate transmission measurements of electrons below 1 keV through suspended monolayer graphene. Monolayer graphene was grown via chemical vapor deposition and transferred onto transmission electron microscopy (TEM) grids. A monochromatic electron gun has been employed to perform the measurements in the 30 – 900 eV range in ultra-high vacuum. The graphene transparency is obtained from the absolute measurement of the direct beam current and the transmitted one, by means of a Faraday cup. We observed a transmission going from 20 to 80% for monolayer graphene within the experimental electron energy range. The high quality and the grid coverage of the suspended graphene has been proved via micro-Raman, X-ray photoemission, electron energy loss spectroscopies and field-emission scanning electron microscopy. After a 550 °C in-vacuum annealing of the samples, the main contribution to the C 1s spectrum is due to the component and the evidence of suspended monolayer graphene has been observed through the -plasmon excitation

    Safety of extended interval dosing immune checkpoint inhibitors:a multicenter cohort study

    Get PDF
    BACKGROUND: Real-life spectrum and survival implications of immune-related adverse events (irAEs) in patients treated with extended interval dosing (ED) immune checkpoint inhibitors (ICIs) are unknown. METHODS: Characteristics of 812 consecutive solid cancer patients who received at least 1 cycle of ED monotherapy (pembrolizumab 400 mg Q6W or nivolumab 480 mg Q4W) after switching from canonical interval dosing (CD; pembrolizumab 200 mg Q3W or nivolumab 240 mg Q2W) or treated upfront with ED were retrieved. The primary objective was to compare irAEs patterns within the same population (before and after switch to ED). irAEs spectrum in patients treated upfront with ED and association between irAEs and overall survival were also described. RESULTS: A total of 550 (68%) patients started ICIs with CD and switched to ED. During CD, 225 (41%) patients developed any grade and 17 (3%) G3 or G4 irAEs; after switching to ED, any grade and G3 or G4 irAEs were experienced by 155 (36%) and 20 (5%) patients. Switching to ED was associated with a lower probability of any grade irAEs (adjusted odds ratio [aOR] = 0.83, 95% confidence interval [CI] = 0.64 to 0.99; P = .047), whereas no difference for G3 or G4 events was noted (aOR = 1.55, 95% CI = 0.81 to 2.94; P = .18). Among patients who started upfront with ED (n = 232, 32%), 107 (41%) developed any grade and 14 (5%) G3 or G4 irAEs during ED. Patients with irAEs during ED had improved overall survival (adjusted hazard ratio [aHR] = 0.53, 95% CI = 0.34 to 0.82; P = .004 after switching; aHR = 0.57, 95% CI = 0.35 to 0.93; P = .025 upfront). CONCLUSIONS: Switching ICI treatment from CD and ED did not increase the incidence of irAEs and represents a safe option also outside clinical trials.</p

    Mass testing of the JUNO experiment 20-inch PMTs readout electronics

    Full text link
    The Jiangmen Underground Neutrino Observatory (JUNO) is a multi-purpose, large size, liquid scintillator experiment under construction in China. JUNO will perform leading measurements detecting neutrinos from different sources (reactor, terrestrial and astrophysical neutrinos) covering a wide energy range (from 200 keV to several GeV). This paper focuses on the design and development of a test protocol for the 20-inch PMT underwater readout electronics, performed in parallel to the mass production line. In a time period of about ten months, a total number of 6950 electronic boards were tested with an acceptance yield of 99.1%

    Implementation and performances of the IPbus protocol for the JUNO Large-PMT readout electronics

    Full text link
    The Jiangmen Underground Neutrino Observatory (JUNO) is a large neutrino detector currently under construction in China. Thanks to the tight requirements on its optical and radio-purity properties, it will be able to perform leading measurements detecting terrestrial and astrophysical neutrinos in a wide energy range from tens of keV to hundreds of MeV. A key requirement for the success of the experiment is an unprecedented 3% energy resolution, guaranteed by its large active mass (20 kton) and the use of more than 20,000 20-inch photo-multiplier tubes (PMTs) acquired by high-speed, high-resolution sampling electronics located very close to the PMTs. As the Front-End and Read-Out electronics is expected to continuously run underwater for 30 years, a reliable readout acquisition system capable of handling the timestamped data stream coming from the Large-PMTs and permitting to simultaneously monitor and operate remotely the inaccessible electronics had to be developed. In this contribution, the firmware and hardware implementation of the IPbus based readout protocol will be presented, together with the performances measured on final modules during the mass production of the electronics

    Validation and integration tests of the JUNO 20-inch PMTs readout electronics

    Full text link
    The Jiangmen Underground Neutrino Observatory (JUNO) is a large neutrino detector currently under construction in China. JUNO will be able to study the neutrino mass ordering and to perform leading measurements detecting terrestrial and astrophysical neutrinos in a wide energy range, spanning from 200 keV to several GeV. Given the ambitious physics goals of JUNO, the electronic system has to meet specific tight requirements, and a thorough characterization is required. The present paper describes the tests performed on the readout modules to measure their performances.Comment: 20 pages, 13 figure

    SARS-CoV-2 omicron (B.1.1.529)-related COVID-19 sequelae in vaccinated and unvaccinated patients with cancer: results from the OnCovid registry

    Full text link
    Background COVID-19 sequelae can affect about 15% of patients with cancer who survive the acute phase of SARS-CoV-2 infection and can substantially impair their survival and continuity of oncological care. We aimed to investigate whether previous immunisation affects long-term sequelae in the context of evolving variants of concern of SARS-CoV-2. Methods OnCovid is an active registry that includes patients aged 18 years or older from 37 institutions across Belgium, France, Germany, Italy, Spain, and the UK with a laboratory-confirmed diagnosis of COVID-19 and a history of solid or haematological malignancy, either active or in remission, followed up from COVID-19 diagnosis until death. We evaluated the prevalence of COVID-19 sequelae in patients who survived COVID-19 and underwent a formal clinical reassessment, categorising infection according to the date of diagnosis as the omicron (B.1.1.529) phase from Dec 15, 2021, to Jan 31, 2022; the alpha (B.1.1.7)-delta (B.1.617.2) phase from Dec 1, 2020, to Dec 14, 2021; and the pre-vaccination phase from Feb 27 to Nov 30, 2020. The prevalence of overall COVID-19 sequelae was compared according to SARS-CoV-2 immunisation status and in relation to post-COVID-19 survival and resumption of systemic anticancer therapy. This study is registered with ClinicalTrials.gov, NCT04393974. Findings At the follow-up update on June 20, 2022, 1909 eligible patients, evaluated after a median of 39 days (IQR 24-68) from COVID-19 diagnosis, were included (964 [ 50 center dot 7%] of 1902 patients with sex data were female and 938 [49 center dot 3%] were male). Overall, 317 (16 center dot 6%; 95% CI 14 center dot 8-18 center dot 5) of 1909 patients had at least one sequela from COVID-19 at the first oncological reassessment. The prevalence of COVID-19 sequelae was highest in the prevaccination phase (191 [19 center dot 1%; 95% CI 16 center dot 4-22 center dot 0] of 1000 patients). The prevalence was similar in the alpha-delta phase (110 [16 center dot 8%; 13 center dot 8- 20 center dot 3] of 653 patients, p=0 center dot 24), but significantly lower in the omicron phase (16 [6 center dot 2%; 3 center dot 5-10 center dot 2] of 256 patients, p<0 center dot 0001). In the alpha- delta phase, 84 (18 center dot 3%; 95% CI 14 center dot 6-22 center dot 7) of 458 unvaccinated patients and three (9 center dot 4%; 1 center dot 9- 27 center dot 3) of 32 unvaccinated patients in the omicron phase had sequelae. Patients who received a booster and those who received two vaccine doses had a significantly lower prevalence of overall COVID-19 sequelae than unvaccinated or partially vaccinated patients (ten [7 center dot 4%; 95% CI 3 center dot 5-13 center dot 5] of 136 boosted patients, 18 [9 center dot 8%; 5 center dot 8-15 center dot 5] of 183 patients who had two vaccine doses vs 277 [ 18 center dot 5%; 16 center dot 5-20 center dot 9] of 1489 unvaccinated patients, p=0 center dot 0001), respiratory sequelae (six [4 center dot 4%; 1 center dot 6-9 center dot 6], 11 [6 center dot 0%; 3 center dot 0-10 center dot 7] vs 148 [9 center dot 9%; 8 center dot 4- 11 center dot 6], p= 0 center dot 030), and prolonged fatigue (three [2 center dot 2%; 0 center dot 1-6 center dot 4], ten [5 center dot 4%; 2 center dot 6-10 center dot 0] vs 115 [7 center dot 7%; 6 center dot 3-9 center dot 3], p=0 center dot 037)

    Potential of Core-Collapse Supernova Neutrino Detection at JUNO

    Get PDF
    JUNO is an underground neutrino observatory under construction in Jiangmen, China. It uses 20kton liquid scintillator as target, which enables it to detect supernova burst neutrinos of a large statistics for the next galactic core-collapse supernova (CCSN) and also pre-supernova neutrinos from the nearby CCSN progenitors. All flavors of supernova burst neutrinos can be detected by JUNO via several interaction channels, including inverse beta decay, elastic scattering on electron and proton, interactions on C12 nuclei, etc. This retains the possibility for JUNO to reconstruct the energy spectra of supernova burst neutrinos of all flavors. The real time monitoring systems based on FPGA and DAQ are under development in JUNO, which allow prompt alert and trigger-less data acquisition of CCSN events. The alert performances of both monitoring systems have been thoroughly studied using simulations. Moreover, once a CCSN is tagged, the system can give fast characterizations, such as directionality and light curve
    • …
    corecore