44 research outputs found

    Right to Occupational Safety: Prevalence of Latent Tuberculosis Infection in Healthcare Workers. A 1-Year Retrospective Survey Carried out at Hospital of Lecce (Italy)

    Get PDF
    Prevention of latent tuberculosis infection (LTBI) in healthcare workers (HCWs) to ensure the “Right to Occupational Safety” is a special challenge globally, as HCWs have a higher risk of acquiring the infection in hospital settings because of frequent close exposure to patients suffering from tuberculosis (TB). Methods: Aretrospective study was performed with the aim of assessing the prevalence of LTBI related to demographical and occupational risk factors among HCWs employed in a large hospital in Italy. The study involved 1461 HCWs screened for LTBI by Mantoux tuberculin skin test (TST) and then confirmed with Interferon Gamma Release Assay (IGRA) test in case of positivity. Immunosuppressed and BGC-vaccinated workers were tested directly with IGRA. Results: LTBI was diagnosed in 4.1% of the HCWs and the prevalence resulted lower than other studies conducted in low TB incidence countries. The variables significantly linked with higher frequency of the infection were: age ≥40 years (OR = 3.14; 95% CI: 1.13–8.74; p < 0.05), length of service ≥15 years (OR = 4.11; 95% CI: 1.48–11.43; p < 0.05) and not being trained on TB prevention (OR = 3.46; 95% CI: 1.85–6.46; p < 0.05). Not trained HCWs presented a higher risk of LTBI also after adjustment for age and length of service, compared to trained HCWs. Conclusions: screening of HCWs for LTBI should be always considered in routinely occupational surveillance in order to early diagnose the infection and prevent its progression. Safety policies in hospital settings centered on workers’ training on TB prevention is crucial to minimize LTBI occurrence in HCWs

    Central Precocious Puberty in Italian Boys: Data From a Large Nationwide Cohort

    Get PDF
    Context: There are only a few nationwide studies on boys with central precocious puberty (CPP) and the last Italian study is a case series of 45 boys that dates back to 2000. Objective: We aimed to evaluate the causes of CPP in boys diagnosed during the last 2 decades in Italy and the relative frequency of forms with associated central nervous system (CNS) abnormalities on magnetic resonance imaging (MRI) compared to idiopathic ones. Methods: We performed a national multicenter retrospective study collecting data from 193 otherwise normal healthy boys with a diagnosis of CPP. Based on MRI findings, the patients were divided into: Group 1, no CNS abnormalities; Group 2, mild abnormalities (incidental findings) unrelated to CPP; and Group 3, causal pathological CNS abnormalities. Results: The MRI findings show normal findings in 86%, mild abnormalities (incidental findings) in 8.3%, and causal pathological CNS abnormalities in 5.7% of the cases. In Group 3, we found a higher proportion of patients with chronological age at diagnosis < 7 years (P = .00001) and body mass index greater than +2 SDS (P < .01). Gonadotropin-releasing hormone analogue therapy was started in 183/193 subjects. The final height appeared in the range of the target height in all groups and in 9 patients in whom the therapy was not started. Conclusion: In our study on a large nationwide cohort of boys referred for precocious puberty signs, the percentage of forms associated with CNS abnormalities was one of the lowest reported in the literature

    Multicentre Italian study of SARS-CoV-2 infection in children and adolescents, preliminary data as at 10 April 2020

    Get PDF
    Data on features of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in children and adolescents are scarce. We report preliminary results of an Italian multicentre study comprising 168 laboratory-confirmed paediatric cases (median: 2.3 years, range: 1 day-17.7 years, 55.9% males), of which 67.9% were hospitalised and 19.6% had comorbidities. Fever was the most common symptom, gastrointestinal manifestations were frequent; two children required intensive care, five had seizures, 49 received experimental treatments and all recovered

    Data of cost-optimal solutions and retrofit design methods for school renovation in a warm climate

    No full text
    "Efficient Solutions and Cost-Optimal Analysis for Existing School Buildings" (Paolo Maria Congedo, Delia D’Agostino, Cristina Baglivo, Giuliano Tornese, Ilaria Zacà) [1] is the paper that refers to this article. It reports the data related to the establishment of several variants of energy efficient retrofit measures selected for two existing school buildings located in the Mediterranean area. In compliance with the cost-optimal analysis described in the Energy Performance of Buildings Directive and its guidelines (EU, Directive, EU 244,) [2] and [3], these data are useful for the integration of renewable energy sources and high performance technical systems for school renovation. The data of cost-efficient high performance solutions are provided in tables that are explained within the following sections. The data focus on the describe school refurbishment sector to which European policies and investments are directed. A methodological approach already used in previous studies about new buildings is followed (Baglivo Cristina, Congedo Paolo Maria, D׳Agostino Delia, Zacà Ilaria, 2015; IlariaZacà, Delia D’Agostino, Paolo Maria Congedo, Cristina Baglivo; Baglivo Cristina, Congedo Paolo Maria, D’Agostino Delia, Zacà Ilaria, 2015; Ilaria Zacà, Delia D’Agostino, Paolo Maria Congedo, Cristina Baglivo, 2015; Paolo Maria Congedo, Cristina Baglivo, IlariaZacà, Delia D’Agostino,2015) [4], [5], [6], [7] and [8]. The files give the cost-optimal solutions for a kindergarten (REF1) and a nursery (REF2) school located in Sanarica and Squinzano (province of Lecce Southern Italy). The two reference buildings differ for construction period, materials and systems. The eleven tables provided contain data about the localization of the buildings, geometrical features and thermal properties of the envelope, as well as the energy efficiency measures related to walls, windows, heating, cooling, dhw and renewables. Output values of energy consumption, gas emission and costs are given for a financial and a macro-economic analysis.This data article provides 288 and 96 combinations for REF1 and REF2, respectively. The output values are obtained using the software ProCasaClima 2015v.2.0.JRC.C.2-Energy Efficiency and Renewable

    Data of cost-optimal solutions and retrofit design methods for school renovation in a warm climate

    Get PDF
    "Efficient Solutions and Cost-Optimal Analysis for Existing School Buildings" (Paolo Maria Congedo, Delia D'Agostino, Cristina Baglivo, Giuliano Tornese, Ilaria Zacà) [1] is the paper that refers to this article. It reports the data related to the establishment of several variants of energy efficient retrofit measures selected for two existing school buildings located in the Mediterranean area. In compliance with the cost-optimal analysis described in the Energy Performance of Buildings Directive and its guidelines (EU, Directive, EU 244,) [2], [3], these data are useful for the integration of renewable energy sources and high performance technical systems for school renovation. The data of cost-efficient high performance solutions are provided in tables that are explained within the following sections. The data focus on the describe school refurbishment sector to which European policies and investments are directed. A methodological approach already used in previous studies about new buildings is followed (Baglivo Cristina, Congedo Paolo Maria, D׳Agostino Delia, Zacà Ilaria, 2015; IlariaZacà, Delia D'Agostino, Paolo Maria Congedo, Cristina Baglivo; Baglivo Cristina, Congedo Paolo Maria, D'Agostino Delia, Zacà Ilaria, 2015; Ilaria Zacà, Delia D'Agostino, Paolo Maria Congedo, Cristina Baglivo, 2015; Paolo Maria Congedo, Cristina Baglivo, IlariaZacà, Delia D'Agostino,2015) [4], [5], [6], [7], [8]. The files give the cost-optimal solutions for a kindergarten (REF1) and a nursery (REF2) school located in Sanarica and Squinzano (province of Lecce Southern Italy). The two reference buildings differ for construction period, materials and systems. The eleven tables provided contain data about the localization of the buildings, geometrical features and thermal properties of the envelope, as well as the energy efficiency measures related to walls, windows, heating, cooling, dhw and renewables. Output values of energy consumption, gas emission and costs are given for a financial and a macro-economic analysis. This data article provides 288 and 96 combinations for REF1 and REF2, respectively. The output values are obtained using the software ProCasaClima 2015v.2.0

    Efficient Solutions and Cost-Optimal Analysis for Existing School Buildings

    Get PDF
    The recast of the energy performance of buildings directive (EPBD) describes a comparative methodological framework to promote energy efficiency and establish minimum energy performance requirements in buildings at the lowest costs. The aim of the cost-optimal methodology is to foster the achievement of nearly zero energy buildings (nZEBs), the new target for all new buildings by 2020, characterized by a high performance with a low energy requirement almost covered by renewable sources. The paper presents the results of the application of the cost-optimal methodology in two existing buildings located in the Mediterranean area. These buildings are a kindergarten and a nursery school that differ in construction period, materials and systems. Several combinations of measures have been applied to derive cost-effective efficient solutions for retrofitting. The cost-optimal level has been identified for each building and the best performing solutions have been selected considering both a financial and a macroeconomic analysis. The results illustrate the suitability of the methodology to assess cost-optimality and energy efficiency in school building refurbishment. The research shows the variants providing the most cost-effective balance between costs and energy saving. The cost-optimal solution reduces primary energy consumption by 85% and gas emissions by 82%–83% in each reference building

    Differences in taste and smell perception between type 2 diabetes mellitus patients and healthy controls

    No full text
    Background and Aims: Taste and smell senses are essential determinants of food choice which, in turn, may contribute to the development of chronic diseases, including diabetes. Although past studies have evaluated the relationship between type 2 diabetes mellitus (DM2) and senses disorders, this relationship still remains controversial. In this study, we evaluated taste and smell perception in DM2 patients and healthy controls (HC). Moreover, in DM2 patients we analyzed the association of chemosensory impairments with anthropometric and clinical outcomes (e.g. Body Mass Index (BMI), Fasting blood glucose (FBG), drugs, cardiovascular diseases (CVD) and hypertension). Methods and Results: The study included 94 DM2 patients and 244 HC. Taste recognition for 6-n-propylthiouracil (PROP), quinine, citric acid, sucrose and sodium chloride (NaCl) compounds was assessed using a filter paper method, while smell recognition of 12 odorants was performed using a sniffing sticks test. We found that a higher percentage of DM2 patients showed identification impairment in salt taste (22% vs. 5%, p-value<0.0009) and smell recognition (55% vs. 27%, p-value=0.03) compared to HC. We also observed that 65% of hypertensive DM2 subjects presented smell identification impairment respect to 18% of non-hypertensive patients (p-value=0.019). Finally, patients with impairments in both taste and smell showed elevated FBG compared to patients without impairment (149.6 vs.124.3 mg/dL, p-value=0.04). Conclusion: The prevalence of taste and smell identification impairments was higher in DM2 patients compared with HC and a possible relationship with glycemic levels emerged
    corecore