724 research outputs found
The effects of intramuscular tenotomy on the lengthening characteristics of tibialis posterior: high versus low intramuscular tenotomy
BACKGROUND: Lengthening of soft-tissue contractures is frequently required in children with a wide variety of congenital and acquired deformities. However, little is known about the biomechanics of surgical procedures which are commonly used in contracture surgery, or if variations in technique may have a bearing on surgical outcomes. We investigated the hypothesis that the site of intramuscular tenotomy (IMT) within the muscle-tendon-unit (MTU) of the tibialis posterior (TP) would affect the lengthening characteristics. METHODS: We performed a randomized trial on paired cadaver tibialis posterior muscle-tendon-units (TP-MTUs). By random allocation, one of each pair of formalin-preserved TP-MTUs received a high IMT, and the other a low IMT. These were individually tensile-tested with an Instron(Âź) machine under controlled conditions. A graph of load (Newtons) versus displacement (millimetres) was generated for each pair of tests. The differences in lengthening and load at failure for each pair of TP-MTUs were noted and compared using paired t tests. RESULTS: We found 48% greater lengthening for low IMT compared to high IMT for a given load (PÂ =Â 0.004, two tailed t test). Load at failure was also significantly lower for the low IMT. These findings confirm our hypothesis that the site of the tenotomy affects the amount of lengthening achieved. This may contribute to the reported variability in clinical outcome. CONCLUSIONS: Understanding the relationship between tenotomy site and lengthening may allow surgeons to vary the site of the tenotomy in order to achieve pre-determined surgical goals. It may be possible to control the surgical "dose" by altering the position of the intramuscular tenotomy within the muscle-tendon-unit
WARP: a WIMP double phase Argon detector
The WARP programme for dark matter search with a double phase argon detector
is presented. In such a detector both excitation and ionization produced by an
impinging particle are evaluated by the contemporary measurement of primary
scintillation and secondary (proportional) light signal, this latter being
produced by extracting and accelerating ionization electrons in the gas phase.
The proposed technique, verified on a 2.3 liters prototype, could be used to
efficiently discriminate nuclear recoils, induced by WIMP's interactions, and
measure their energy spectrum. An overview of the 2.3 liters results and of the
proposed 100 liters detector is shown.Comment: Proceeding for IDM200
Demonstration and Comparison of Operation of Photomultiplier Tubes at Liquid Argon Temperature
Liquified noble gases are widely used as a target in direct Dark Matter
searches. Signals from scintillation in the liquid, following energy deposition
from the recoil nuclei scattered by Dark Matter particles (e.g. WIMPs), should
be recorded down to very low energies by photosensors suitably designed to
operate at cryogenic temperatures. Liquid Argon based detectors for Dark Matter
searches currently implement photo multiplier tubes for signal read-out. In the
last few years PMTs with photocathodes operating down to liquid Argon
temperatures (87 K) have been specially developed with increasing Quantum
Efficiency characteristics. The most recent of these, Hamamatsu Photonics Mod.
R11065 with peak QE up to about 35%, has been extensively tested within the R&D
program of the WArP Collaboration. During these testes the Hamamatsu PMTs
showed superb performance and allowed obtaining a light yield around 7
phel/keVee in a Liquid Argon detector with a photocathodic coverage in the 12%
range, sufficient for detection of events down to few keVee of energy
deposition. This shows that this new type of PMT is suited for experimental
applications, in particular for new direct Dark Matter searches with LAr-based
experiments
- âŠ