605 research outputs found

    Human Fetal Osteoblast Response on Poly (Methyl Methacrylate)/Polystyrene Demixed Thin Film Blends: Surface Chemistry Vs Topography Effects

    Get PDF
    Recent advances in materials sciences have allowed for the development and fabrication of biomaterials that are capable of providing requisite cues to instigate cells to respond in a predictable fashion. We have developed a series of poly(methyl methacrylate)/polystyrene (PMMA/PS) polymer demixed thin films with nanotopographies ranging from nanoislands to nanopits to study the response of human fetal osteoblast cells (hFOBs). When PMMA was in excess in the blend composition, a nanoisland topography dominated, whereas a nanopit topography dominated when PS was in excess. PMMA was found to segregate to the top of the nanoisland morphology with PS preferring the substrate interface. To further ascertain the effects of surface chemistry vs topography, we plasma treated the polymer demixed films using an atmospheric pressure dielectric barrier discharge reactor to alter the surface chemistry. Our results have shown that hFOBs did not have an increased short-term cellular response on pristine polymer demixed surfaces. However, increasing the hydrophilicty/wettability of the surfaces by oxygen functionalization causes an increase in the cellular response. These results indicate that topography alone is not sufficient to induce a positive cellular response, but the underlying surface chemistry is also important in regulating cell function

    A transient helix in the disordered region of dynein light intermediate chain links the motor to structurally diverse adaptors for cargo transport

    Get PDF
    All animal cells use the motor cytoplasmic dynein 1 (dynein) to transport diverse cargo toward microtubule minus ends and to organize and position microtubule arrays such as the mitotic spindle. Cargo-specific adaptors engage with dynein to recruit and activate the motor, but the molecular mechanisms remain incompletely understood. Here, we use structural and dynamic nuclear magnetic resonance (NMR) analysis to demonstrate that the C-terminal region of human dynein light intermediate chain 1 (LIC1) is intrinsically disordered and contains two short conserved segments with helical propensity. NMR titration experiments reveal that the first helical segment (helix 1) constitutes the main interaction site for the adaptors Spindly (SPDL1), bicaudal D homolog 2 (BICD2), and Hook homolog 3 (HOOK3). In vitro binding assays show that helix 1, but not helix 2, is essential in both LIC1 and LIC2 for binding to SPDL1, BICD2, HOOK3, RAB-interacting lysosomal protein (RILP), RAB11 family-interacting protein 3 (RAB11FIP3), ninein (NIN), and trafficking kinesin-bind-ing protein 1 (TRAK1). Helix 1 is sufficient to bind RILP, whereas other adaptors require additional segments preceding helix 1 for efficient binding. Point mutations in the C-terminal helix 1 of Caenorhabditis elegans LIC, introduced by genome editing, severely affect development, locomotion, and life span of the animal and disrupt the distribution and transport kinetics of membrane cargo in axons of mechanosensory neurons, identical to what is observed when the entire LIC C-terminal region is deleted. Deletion of the C-terminal helix 2 delays dynein-dependent spindle positioning in the one-cell embryo but overall does not significantly perturb dynein function. We conclude that helix 1 in the intrinsically disordered region of LIC provides a conserved link between dynein and structurally diverse cargo adaptor families that is critical for dynein function in vivo.This work was financed by the Fundo Europeu de Desenvolvimento Regional (FEDER) through the Norte Portugal Regional Operational Programme (NORTE 2020), Portugal 2020 (RG); by the Fundação para a Ciência e a Tecnologia (FCT)/Ministério da Ciência, Tecnologia e Ensino Superior in the framework of the project NORTE-01-0145-FEDER-030507 (RG); by FCT fellowships IF/01015/2013/CP1157/CT0006 (RG) and SFRH/ BPD/101898/2014 (DJB); by the European Research Council under the European Union’s Seventh Framework Programme, ERC grant agreement no. ERC-2013-StG-338410-DYNEINOME (RG), and by a start-up package of the University of Colorado (BV). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript

    Variable-focus microlenses as a potential technology for endoscopy

    Get PDF
    Using a new device which contains an array of microlenses whose focal lengths can be electrically varied, we have been able to control the input from one microlens to a single mode fibre using an applied voltage. For such a microlens array many closely-spaced focal spots can be generated in parallel, and electrically switched to address, potentially, an array of receiver fibres. We show how the particular switching characteristics of the device, whereby the lenses switch from diverging to converging, serves in turn to disperse light and to focus it into the fibre

    Stent Design, Restenosis and Recurrent Stroke After Carotid Artery Stenting in the International Carotid Stenting Study

    Get PDF
    BACKGROUND AND PURPOSE: Open-cell carotid artery stents are associated with a higher peri-procedural stroke risk than closed-cell stents. However, the effect of stent design on long-term durability of carotid artery stenting (CAS) is unknown. We compared the medium- to long-term risk of restenosis and ipsilateral stroke between patients treated with open-cell stents versus closed-cell stents in the ICSS (International Carotid Stenting Study). METHODS: Patients with symptomatic carotid stenosis were randomized to CAS or endarterectomy and followed with duplex ultrasound for a median of 4.0 years. We analyzed data from patients with completed CAS procedures, known stent design, and available ultrasound follow-up. The primary outcome, moderate or higher restenosis (≥50%) was defined as a peak systolic velocity of >1.3 m/s on ultrasound or occlusion of the treated internal carotid artery and analyzed with interval-censored models. RESULTS: Eight hundred fifty-five patients were allocated to CAS. Seven hundred fourteen patients with completed CAS and known stent design were included in the current analysis. Of these, 352 were treated with open-cell and 362 with closed-cell stents. Moderate or higher restenosis occurred significantly less frequently in patients treated with open-cell (n=113) than closed-cell stents (n=154; 5-year risks were 35.5% versus 46.0%; unadjusted hazard ratio, 0.68; 95% CI, 0.53–0.88). There was no significant difference in the risk of severe restenosis (≥70%) after open-cell stenting (n=27) versus closed-cell stenting (n=43; 5-year risks, 8.6% versus 12.7%; unadjusted hazard ratio, 0.63; 95% CI, 0.37–1.05). The risk of ipsilateral stroke beyond 30 days after treatment was similar with open-cell and closed-cell stents (hazard ratio, 0.78; 95% CI, 0.35–1.75). CONCLUSIONS: Moderate or higher restenosis after CAS occurred less frequently in patients treated with open-cell stents than closed-cell stents. However, both stent designs were equally effective at preventing recurrent stroke during follow-up. CLINICAL TRIAL REGISTRATION: URL: http://www.isrctn.com/. Unique identifier: ISRCTN25337470

    Placenta microstructure and microcirculation imaging with diffusion MRI

    Get PDF
    PURPOSE: To assess which microstructural models best explain the diffusion-weighted MRI signal in the human placenta. METHODS: The placentas of nine healthy pregnant subjects were scanned with a multishell, multidirectional diffusion protocol at 3T. A range of multicompartment biophysical models were fit to the data, and ranked using the Bayesian information criterion. RESULTS: Anisotropic extensions to the intravoxel incoherent motion model, which consider the effect of coherent orientation in both microvascular structure and tissue microstructure, consistently had the lowest Bayesian information criterion values. Model parameter maps and model selection results were consistent with the physiology of the placenta and surrounding tissue. CONCLUSION: Anisotropic intravoxel incoherent motion models explain the placental diffusion signal better than apparent diffusion coefficient, intravoxel incoherent motion, and diffusion tensor models, in information theoretic terms, when using this protocol. Future work will aim to determine if model-derived parameters are sensitive to placental pathologies associated with disorders, such as fetal growth restriction and early-onset pre-eclampsia

    Game theory of mind

    Get PDF
    This paper introduces a model of ‘theory of mind’, namely, how we represent the intentions and goals of others to optimise our mutual interactions. We draw on ideas from optimum control and game theory to provide a ‘game theory of mind’. First, we consider the representations of goals in terms of value functions that are prescribed by utility or rewards. Critically, the joint value functions and ensuing behaviour are optimised recursively, under the assumption that I represent your value function, your representation of mine, your representation of my representation of yours, and so on ad infinitum. However, if we assume that the degree of recursion is bounded, then players need to estimate the opponent's degree of recursion (i.e., sophistication) to respond optimally. This induces a problem of inferring the opponent's sophistication, given behavioural exchanges. We show it is possible to deduce whether players make inferences about each other and quantify their sophistication on the basis of choices in sequential games. This rests on comparing generative models of choices with, and without, inference. Model comparison is demonstrated using simulated and real data from a ‘stag-hunt’. Finally, we note that exactly the same sophisticated behaviour can be achieved by optimising the utility function itself (through prosocial utility), producing unsophisticated but apparently altruistic agents. This may be relevant ethologically in hierarchal game theory and coevolution

    Emerging pharmacotherapy of tinnitus

    Get PDF
    Tinnitus, the perception of sound in the absence of an auditory stimulus, is perceived by about 1 in 10 adults, and for at least 1 in 100, tinnitus severely affects their quality of life. Because tinnitus is frequently associated with irritability, agitation, stress, insomnia, anxiety and depression, the social and economic burdens of tinnitus can be enormous. No curative treatments are available. However, tinnitus symptoms can be alleviated to some extent. The most widespread management therapies consist of auditory stimulation and cognitive behavioral treatment, aiming at improving habituation and coping strategies. Available clinical trials vary in methodological rigor and have been performed for a considerable number of different drugs. None of the investigated drugs have demonstrated providing replicable long-term reduction of tinnitus impact in the majority of patients in excess of placebo effects. Accordingly, there are no FDA or European Medicines Agency approved drugs for the treatment of tinnitus. However, in spite of the lack of evidence, a large variety of different compounds are prescribed off-label. Therefore, more effective pharmacotherapies for this huge and still growing market are desperately needed and even a drug that produces only a small but significant effect would have an enormous therapeutic impact. This review describes current and emerging pharmacotherapies with current difficulties and limitations. In addition, it provides an estimate of the tinnitus market. Finally, it describes recent advances in the tinnitus field which may help overcome obstacles faced in the pharmacological treatment of tinnitus. These include incomplete knowledge of tinnitus pathophysiology, lack of well-established animal models, heterogeneity of different forms of tinnitus, difficulties in tinnitus assessment and outcome measurement and variability in clinical trial methodology. © 2009 Informa UK Ltd.Fil: Langguth, Berthold. Universitat Regensburg; AlemaniaFil: Salvi, Richard. State University of New York; Estados UnidosFil: Elgoyhen, Ana Belen. Consejo Nacional de Investigaciones Científicas y Técnicas. Instituto de Investigaciones en Ingeniería Genética y Biología Molecular "Dr. Héctor N. Torres"; Argentin

    Optimal cut-off criteria for duplex ultrasound for the diagnosis of restenosis in stented carotid arteries: Review and protocol for a diagnostic study

    Get PDF
    Background: Carotid angioplasty with stenting is a relatively new, increasingly used, less-invasive treatment for the treatment of symptomatic carotid artery stenosis. It is being evaluated in ongoing and nearly finished randomized trials. An important factor in the evaluation of stents is the occurrence of in-stent restenosis. An un-stented carotid artery is likely to have a more elastic vessel wall than a stented one, even if stenosis is present. Therefore, duplex ultrasound cut-off criteria for the degrees of an in-stent stenosis, based on blood velocity parameters, are probably different from the established cut-offs used for un-stented arteries. Routine criteria can not be applied to stented arteries but new criteria need to be established for this particular purpose. Methods/Design: Current literature was systematically reviewed. From the selected studies, the following data were extracted: publication year, population size, whether the study was prospective, which reference test was used, and if there was an indication for selection bias and for verification bias in particular. Previous studies often were retrospective, or the reference test (DSA or CTA) was carried out only when a patient was suspected of having restenosis at DUS, which may result in verification bias. Results: In general, the cut-off values are higher than those reported for unstented arteries. Previous studies often were retrospective, or the reference test (DSA or CTA) was carried out only when a patient was suspected of having restenosis at DUS, which may result in verification bias. Discussion: To address the deficiencies of the existing studies, we propose a prospective cohort study nested within the International Carotid Stenting Study (ICSS), an international multi-centre trial in which over 1,700 patients have been randomised between stenting and CEA. In this cohort we will enrol a minimum of 300 patients treated with a stent. All patients undergo regular DUS examination at the yearly follow-up visit according to the ICSS protocol. To avoid verification bias, an additional computed tomography angiography (CTA) will be performed as a reference test in all consecutive patients, regardless of the degree of stenosis on the initial DUS test

    Light dark matter and Z′Z' dark force at colliders

    Full text link
    Light Dark Matter, <10<10 GeV, with sizable direct detection rate is an interesting and less explored scenario. Collider searches can be very powerful, such as through the channel in which a pair of dark matter particle are produced in association with a jet. It is a generic possibility that the mediator of the interaction between DM and the nucleus will also be accessible at the Tevatron and the LHC. Therefore, collider search of the mediator can provide a more comprehensive probe of the dark matter and its interactions. In this article, to demonstrate the complementarity of these two approaches, we focus on the possibility of the mediator being a new U(1)′U(1)' gauge boson, which is probably the simplest model which allows a large direct detection cross section for a light dark matter candidate. We combine searches in the monojet+MET channel and dijet resonance search for the mediator. We find that for the mass of Z′Z' between 250 GeV and 4 TeV, resonance searches at the colliders provide stronger constraints on this model than the monojet+MET searches.Comment: 23 pages and 14 figure
    • …
    corecore