751 research outputs found

    Hilbert Lattice Equations

    Full text link
    There are five known classes of lattice equations that hold in every infinite dimensional Hilbert space underlying quantum systems: generalised orthoarguesian, Mayet's E_A, Godowski, Mayet-Godowski, and Mayet's E equations. We obtain a result which opens a possibility that the first two classes coincide. We devise new algorithms to generate Mayet-Godowski equations that allow us to prove that the fourth class properly includes the third. An open problem related to the last class is answered. Finally, we show some new results on the Godowski lattices characterising the third class of equations.Comment: 24 pages, 3 figure

    GePEToS : A Geant4 Monte Carlo simulation package for Positron Emission Tomography

    Full text link
    GePEToS is a simulation framework developed over the last few years for assessing the instrumental performance of future PET scanners. It is based on Geant4, written in Object-Oriented C++ and runs on Linux platforms. The validity of GePEToS has been tested on the well-known Siemens ECAT EXACT HR+ camera. The results of two application examples are presented : the design optimization of a liquid Xe micro-PET camera dedicated to small animal imaging as well as the evaluation of the effect of a strong axial magnetic field on the image resolution of a Concorde P4 micro-PET camera.Comment: 5 pages, 12 figures, submitted to IEEE Transactions on Nuclear Scienc

    MIMAC-He3 : A Micro-TPC Matrix of Chambers of He3 for direct detection of Wimps

    Full text link
    The project of a micro-TPC matrix of chambers of \hetrois for direct detection of non-baryonic dark matter is presented. The privileged properties of He3 are highlighted. The double detection (ionization - projection of tracks) is explained and its rejection evaluated. The potentialities of MIMAC-He3 for supersymmetric dark matter search are discussed.Comment: to appear in Proc. of the 9th International Conference on Topics in Astroparticle and Underground Physics (TAUP 2005), Zaragoza, Sept. 200

    Thigh fat and muscle each contribute to excess cardiometabolic risk in South Asians, independent of visceral adipose tissue.

    Get PDF
    OBJECTIVE: To compare fat distribution and associations between fat depots and cardiometabolic traits in South Asians and Europeans. METHODS: Five hundred and fourteen South Asians and 669 Europeans, aged 56-86. Questionnaires, record review, blood testing, and coronary artery calcification scores provided diabetes and clinical plus subclinical coronary heart disease (CHD) diagnoses. Abdominal visceral (VAT) and subcutaneous adipose tissue, thigh subcutaneous adipose tissue (TSAT), intermuscular and intramuscular thigh fat and thigh muscle were measured by CT. RESULTS: Accounting for body size, South Asians had greater VAT and TSAT than Europeans, but less thigh muscle. Associations between depots and disease were stronger in South Asians than Europeans. In multivariable analyses in South Asians, VAT was positively associated with diabetes and CHD, while TSAT and thigh muscle were protective for diabetes, and thigh muscle for CHD. Differences in VAT and thigh muscle only partially explained the excess diabetes and CHD in South Asians versus Europeans. Insulin resistance did not account for the effects of TSAT or thigh muscle. CONCLUSIONS: Greater VAT and TSAT and lesser thigh muscle in South Asians contributed to ethnic differences in cardiometabolic disease. Effects of TSAT and thigh muscle were independent of insulin resistance

    Evidence that conflict regarding size of haemodynamic response to interventricular delay optimization of cardiac resynchronization therapy may arise from differences in how atrioventricular delay is kept constant.

    Get PDF
    Aims: Whether adjusting interventricular (VV) delay changes haemodynamic efficacy of cardiac resynchronization therapy (CRT) is controversial, with conflicting results. This study addresses whether the convention for keeping atrioventricular (AV) delay constant during VV optimization might explain these conflicts. / Method and results: Twenty-two patients in sinus rhythm with existing CRT underwent VV optimization using non-invasive systolic blood pressure. Interventricular optimization was performed with four methods for keeping the AV delay constant: (i) atrium and left ventricle delay kept constant, (ii) atrium and right ventricle delay kept constant, (iii) time to the first-activated ventricle kept constant, and (iv) time to the second-activated ventricle kept constant. In 11 patients this was performed with AV delay of 120 ms, and in 11 at AV optimum. At AV 120 ms, time to the first ventricular lead (left or right) was the overwhelming determinant of haemodynamics (13.75 mmHg at ±80 ms, P < 0.001) with no significant effect of time to second lead (0.47 mmHg, P = 0.50), P < 0.001 for difference. At AV optimum, time to first ventricular lead again had a larger effect (5.03 mmHg, P < 0.001) than time to second (2.92 mmHg, P = 0.001), P = 0.02 for difference. / Conclusion: Time to first ventricular activation is the overwhelming determinant of circulatory function, regardless of whether this is the left or right ventricular lead. If this is kept constant, the effect of changing time to the second ventricle is small or nil, and is not beneficial. In practice, it may be advisable to leave VV delay at zero. Specifying how AV delay is kept fixed might make future VV delay research more enlightening

    Low energy measurements with Helium Micromegas micro-TPC

    Full text link
    The measurement of the ionization produced by particles in a medium presents a great interest in several fields from metrology to particule physics and cosmology. The ionization quenching factor is defined as the fraction of energy released by ionisation by a recoil in a medium compared with its kinetic energy. At low energy, in the range of a few keV, the ionization falls rapidly and systematic measurement are needed. We have developped an experimental setup devoted to the measurement of low energy (keV) ionization quenching factor for the MIMAC project. The ionization produced in the gas has been measured with a Micromegas detector filled with Helium gas mixture.Comment: Proceedings of the fourth international symposium on large TPCs for low energy rare event detection, Paris, France, Dec. 2008 To appear in Journal of Physic

    Dark matter directional detection with MIMAC

    Full text link
    MiMac is a project of micro-TPC matrix of gaseous (He3, CF4) chambers for direct detection of non-baryonic dark matter. Measurement of both track and ionization energy will allow the electron-recoil discrimination, while access to the directionnality of the tracks will open a unique way to distinguish a geniune WIMP signal from any background. First reconstructed tracks of 5.9 keV electrons are presented as a proof of concept.Comment: 4 pages, proc. of the 44th Rencontres De Moriond: Electroweak Interactions And Unified Theories, 7-14 Mar 2009, La Thuile, Ital

    Measurement of the electron drift velocity for directional dark matter detectors

    Full text link
    Three-dimensional track reconstruction is a key issue for directional Dark Matter detection. It requires a precise knowledge of the electron drift velocity. Magboltz simulations are known to give a good evaluation of this parameter. However, large TPC operated underground on long time scale may be characterized by an effective electron drift velocity that may differ from the value evaluated by simulation. In situ measurement of this key parameter is hence a way to avoid bias in the 3D track reconstruction. We present a dedicated method for the measurement of the electron drift velocity with the MIMAC detector. It is tested on two gas mixtures : CF4\rm CF_4 and CF4+CHF3\rm CF_4+CHF_3. We also show that adding CHF3\rm CHF_3 allows us to lower the electron drift velocity while keeping almost the same Fluorine content of the gas mixture.Comment: Proceedings of the 4th international conference on Directional Detection of Dark Matter (CYGNUS 2013), 10-12 June 2013, Toyama, Japa

    In situ measurement of the electron drift velocity for upcoming directional Dark Matter detectors

    Full text link
    Three-dimensional track reconstruction is a key issue for directional Dark Matter detection and it requires a precise knowledge of the electron drift velocity. Magboltz simulations are known to give a good evaluation of this parameter. However, large TPC operated underground on long time scale may be characterized by an effective electron drift velocity that may differ from the value evaluated by simulation. In situ measurement of this key parameter is hence needed as it is a way to avoid bias in the 3D track reconstruction. We present a dedicated method for the measurement of the electron drift velocity with the MIMAC detector. It is tested on two gas mixtures: CF4 and CF4 + CHF3. The latter has been chosen for the MIMAC detector as we expect that adding CHF3 to pure CF4 will lower the electron drift velocity. This is a key point for directional Dark Matter as the track sampling along the drift field will be improved while keeping almost the same Fluorine content of the gas mixture. We show that the drift velocity at 50 mbar is reduced by a factor of about 5 when adding 30% of CHF3.Comment: 19 pages, 14 figures. Minor corrections, matches published version in JINS
    corecore