445 research outputs found

    Running performance of an aerodynamic journal bearing with squeeze film effect

    Get PDF
    Results of theoretical and experimental studies concerning the performance of an aerodynamic journal bearing which running is assisted by squeeze film ultrasonic levitation (SFUL) are presented in this paper. The SFUL mechanism not only can separate journal from the bearing at the start and stop phases of operation but also can significantly contribute to the dynamic stability of the bearing when it runs at speed. Computer calculations and validating experimental testing of a prototype device were carried out. It was found that that SFUL mechanism, when combined with aerodynamic lift, extends the threshold speed of bearing’s instability by almost four times comparing to that of a bearing operating without SFUL. Typically, the bearing running without SFUL became unstable at the speed of 300 rpm while with the SFUL the speed at which instability became apparent was 10,000 rpm (calculated result) or 13,200 (experimental result)

    Appropriate margin for planning target volume for breast radiotherapy during deep inspiration breath-hold by variance component analysis

    Get PDF
    BACKGROUND: This study aimed to quantify errors by using a cine electronic portal imaging device (cine EPID) during deep inspiration breath-hold (DIBH) for left-sided breast cancer and to estimate the planning target volume (PTV) by variance component analysis. METHODS: This study included 25 consecutive left-sided breast cancer patients treated with whole-breast irradiation (WBI) using DIBH. Breath-holding was performed while monitoring abdominal anterior-posterior (AP) motion using the Real-time Position Management (RPM) system. Cine EPID was used to evaluate the chest wall displacements in patients. Cine EPID images of the patients (309, 609 frames) were analyzed to detect the edges of the chest wall using a Canny filter. The errors that occurred during DIBH included differences between the chest wall position detected by digitally reconstructed radiographs and that of all cine EPID images. The inter-patient, inter-fraction, and intra-fractional standard deviations (SDs) in the DIBH were calculated, and the PTV margin was estimated by variance component analysis. RESULTS: The median patient age was 55 (35-79) years, and the mean irradiation time was 20.4 ± 1.7 s. The abdominal AP motion was 1.36 ± 0.94 (0.14-5.28) mm. The overall mean of the errors was 0.30 mm (95% confidence interval: - 0.05-0.65). The inter-patient, inter-fraction, and intra-fractional SDs in the DIBH were 0.82 mm, 1.19 mm, and 1.63 mm, respectively, and the PTV margin was calculated as 3.59 mm. CONCLUSIONS: Errors during DIBH for breast radiotherapy were monitored using EPID images and appropriate PTV margins were estimated by variance component analysis

    An Assessment of Radioactivity Levels of 210Pb and 40K in Tobacco and Radiation Exposure from Smoking

    Get PDF
    No research has been conducted on the radiation influence of tobacco on the alimentary system, although there have been some previous works on the respiratory system. In this study, the radioactive concentrations of 210Pb and 40K in a cigarette sample were first measured. The transfer factors of the nuclides from tobacco into smoke and solution (saliva and/or alcohol) were then examined. Moreover, the radiation doses from smoke inhalation were also evaluated. The radioactive concentrations of 210Pb and 40K in the cigarette tobacco were 0.01 and 0.3 Bq/cigarette. Since this 210Pb activity and the 210Po activity previously reported for the same sample were comparable, it can be concluded that there was a radioactive equilibrium between the 2 nuclides. The observed transfer factor of 210Pb (12%) into smoke was almost the same as that of 40K (15%), whereas the reported value for 210Po (60%) was significantly higher. The radiation doses due to inhalation of cigarette smoke varied from organ to organ, depending on the organotropic properties of the nuclide. For example, the kidneys, respiratory tract, and spleen showed relatively high doses from 210Pb and 210Po. The leaching rates indicated an inconsistent tendency related to solution types. This result could suggest that alcohol drinking, which is common in smokers, does not especially enhance the leaching characteristics

    Automatic measurement of beam‐positioning accuracy at off‐isocenter positions

    Get PDF
    [Purpose] This study performed an automatic measurement of the off-axis beam-positioning accuracy at a single isocenter via the TrueBeam Developer mode and evaluated the beam-positioning accuracy considering the effect of couch rotational errors. [Methods] TrueBeam STx and the Winston–Lutz test-dedicated phantom, with a 3 mm diameter steel ball, were used in this study. The phantom was placed on the treatment couch, and the Winston–Lutz test was performed at the isocenter for four gantry angles (0°, 90°, 180°, and 270°) using an electronic portal imaging device. The phantom offset positions were at distances of 0, 25, 50, 75, and 100 mm from the isocenter along the superior–inferior, anterior–posterior, and left–right directions. Seventeen patterns of multileaf collimator-shaped square fields of 10 × 10 mm² were created at the isocenter and off-axis positions for each gantry angle. The beam-positioning accuracy was evaluated with couch rotation along the yaw-axis (0°, ± 0.5°, and ± 1.0°). [Results] The mean beam-positioning errors at the isocenter and off-isocenter distances (from the isocenter to ±100 mm) were 0.46–0.60, 0.44–0.91, and 0.42–1.11 mm for the couch angles of 0°, ±0.5°, and ±1°, respectively. The beam-positioning errors increased as the distance from the isocenter and couch rotation increased. [Conclusion] These findings suggest that the beam-positioning accuracy at the isocenter and off-isocenter positions can be evaluated quickly and automatically using the TrueBeam Developer mode. The proposed procedure is expected to contribute to an efficient evaluation of the beam-positioning accuracy at off-isocenter positions
    corecore