52 research outputs found
A clinical trial comparing ultrasound-guided ilioinguinal/iliohypogastric nerve block to transversus abdominis plane block for analgesia following open inguinal hernia repair
Objective: To compare the efficacy of ilioinguinal/iliohypogastric (IINB) nerve block to transversus abdominis plane (TAP) block in controlling incisional pain after open inguinal hernia repair. Patients and methods: This was a prospective randomized clinical trial of 90 patients who received either IINB (N=45) or TAP block (N=45) using 0.2 bupivacaine 15 mL under ultrasound (US) guidance based on a random assignment in the postanesthesia care unit after having an open repair of inguinal hernia. Numeric Rating Scale (NRS) scores were recorded immediately following, 4, 8, 12, and 24 hours after completion of the block. NRS scores at rest and during movement were recorded 24, 36, and 48 hours after surgery. Analgesic satisfaction level was also evaluated by a Likert-based patient questionnaire. Results: NRS scores were lower in the IINB group compared to the TAP block group both at rest and during movement. The difference in dynamic pain scores was statistically significant (P=0.017). In addition, analgesic satisfaction was significantly greater in the IINB group than the TAP block group (mean score 2.43 vs 1.84, P=0.001). Postoperative opioid requirements did not differ between the two groups. Conclusion: This study demonstrated that compared to TAP block, local blockade of ilioinguinal and iliohypogastric nerves provides better pain control after open repair of inguinal hernia when both blocks were administered under US guidance. Greater satisfaction scores also reflected superior analgesia in patients receiving IINB. © 2019 Faiz et al
Ion acoustic wave experiments in a high school plasma physics laboratory
We describe a successful alliance between a university and several high schools. The alliance is centered on a laboratory experiment constructed by students and faculty. The experiment involves sophisticated concepts and equipment not readily available in high schools. Much of the experiment is directly related to the science and mathematics learned in high school, with opportunities to extend their understanding by applying it to a research experience. The experiment is in plasma physics, but a similar alliance can be implemented in any area of science. Although the number of high school students affected by any one alliance is small, the impact is potentially large in the scientific life of a participating student or teacher
Energy-Spread Preservation and High Efficiency in a Plasma-Wakefield Accelerator
Energy-efficient plasma-wakefield acceleration of particle bunches with low energy spread is a promising path to realizing compact free-electron lasers and particle colliders. High efficiency and low energy spread can be achieved simultaneously by strong beam loading of plasma wakefields when accelerating bunches with carefully tailored current profiles [M. Tzoufras et al., Phys. Rev. Lett. 101, 145002 (2008)PRLTAO0031-900710.1103/PhysRevLett.101.145002]. We experimentally demonstrate such optimal beam loading in a nonlinear electron-driven plasma accelerator. Bunches with an initial energy of 1 GeV were accelerated by 45 MeV with an energy-transfer efficiency of (42±4)% at a gradient of 1.3 GV/m while preserving per-mille energy spreads with full charge coupling, demonstrating wakefield flattening at the few-percent level
Tunable and precise two-bunch generation at FLASHForward
Beam-driven plasma-wakefield acceleration based on external injection has the
potential to significantly reduce the size of future accelerators. Stability
and quality of the acceleration process substantially depends on the incoming
bunch parameters. Precise control of the current profile is essential for
optimising energy-transfer efficiency and preserving energy spread. At the
FLASHForward facility, driver--witness bunch pairs of adjustable bunch length
and separation are generated by a set of collimators in a dispersive section,
which enables fs-level control of the longitudinal bunch profile. The design of
the collimator apparatus and its commissioning is presented.Comment: 7 pages, 5 figures, to be published in the proceedings of the 4th
European Advanced Accelerator Concepts Workshop, 15-21 September 2019, La
Biodola Bay, Isola d'Elba, Ital
Status of the Horizon 2020 EuPRAXIA conceptual design study
The Horizon 2020 project EuPRAXIA (European Plasma Research Accelerator with eXcellence In Applications) is producing a conceptual design report for a highly compact and cost-effective European facility with multi-GeV electron beams accelerated using plasmas. EuPRAXIA will be set up as a distributed Open Innovation platform with two construction sites, one with a focus on beam-driven plasma acceleration (PWFA) and another site with a focus on laser-driven plasma acceleration (LWFA). User areas at both sites will provide access to free-electron laser pilot experiments, positron generation and acceleration, compact radiation sources, and test beams for high-energy physics detector development. Support centres in four different countries will complement the pan-European implementation of this infrastructure
Eupraxia, a step toward a plasma-wakefield based accelerator with high beam quality
The EuPRAXIA project aims at designing the world's first accelerator based on advanced plasma-wakefield techniques to deliver 5 GeV electron beams that simultaneously have high charge, low emittance and low energy spread, which are required for applications by future user communities. Meeting this challenging objective will only be possible through dedicated effort. Many injection/acceleration schemes and techniques have been explored by means of thorough simulations in more than ten European research institutes. This enables selection of the most appropriate methods for solving each particular problem. The specific challenge of generating, extracting and transporting high charge beams, while maintaining the high quality needed for user applications, are being tackled using innovative approaches. This article highlights preliminary results obtained by the EuPRAXIA collaboration, which also exhibit the required laser and plasma parameters
FLASHForward: plasma wakefield accelerator science for high-average-power applications
The FLASHForward experimental facility is a high-performance test-bed for precision plasma wakefield research, aiming to accelerate high-quality electron beams to GeV-levels in a few centimetres of ionized gas. The plasma is created by ionizing gas in a gas cell either by a high-voltage discharge or a high-intensity laser pulse. The electrons to be accelerated will either be injected internally from the plasma background or externally from the FLASH superconducting RF front end. In both cases, the wakefield will be driven by electron beams provided by the FLASH gun and linac modules operating with a 10 Hz macro-pulse structure, generating 1.25 GeV, 1 nC electron bunches at up to 3 MHz micro-pulse repetition rates. At full capacity, this FLASH bunch-train structure corresponds to 30 kW of average power, orders of magnitude higher than drivers available to other state-of-the-art LWFA and PWFA experiments. This high-power functionality means FLASHForward is the only plasma wakefield facility in the world with the immediate capability to develop, explore and benchmark high-average-power plasma wakefield research essential for next-generation facilities. The operational parameters and technical highlights of the experiment are discussed, as well as the scientific goals and high-average-power outlook.
This article is part of the Theo Murphy meeting issue ‘Directions in particle beam-driven plasma wakefield acceleration’
EuPRAXIA - A compact, cost-efficient particle and radiation source
Plasma accelerators present one of the most suitable candidates for the development of more compact particle acceleration technologies, yet they still lag behind radiofrequency (RF)-based devices when it comes to beam quality, control, stability and power efficiency. The Horizon 2020-funded project EuPRAXIA ("European Plasma Research Accelerator with eXcellence In Applications") aims to overcome the first three of these hurdles by developing a conceptual design for a first international user facility based on plasma acceleration. In this paper we report on the main features, simulation studies and potential applications of this future research infrastructure
Horizon 2020 EuPRAXIA design study
The Horizon 2020 Project EuPRAXIA ("European Plasma Research Accelerator with eXcellence In Applications") is preparing a conceptual design report of a highly compact and cost-effective European facility with multi-GeV electron beams using plasma as the acceleration medium. The accelerator facility will be based on a laser and/or a beam driven plasma acceleration approach and will be used for photon science, high-energy physics (HEP) detector tests, and other applications such as compact X-ray sources for medical imaging or material processing. EuPRAXIA started in November 2015 and will deliver the design report in October 2019. EuPRAXIA aims to be included on the ESFRI roadmap in 2020
- …