19 research outputs found
The relation between endothelial dependent flow mediated dilation of the brachial artery and coronary collateral development – a cross sectional study
<p>Abstract</p> <p>Background</p> <p>Endothelial dysfunction is thought to be a potential mechanism for the decreased presence of coronary collaterals. The aim of the study was to investigate the association between systemic endothelial function and the extent of coronary collaterals.</p> <p>Methods</p> <p>We investigated the association between endothelial function assessed via flow mediated dilation (FMD) of the brachial artery following reactive hyperemia and the extent of coronary collaterals graded from 0 to 3 according to Rentrop classification in a cohort of 171 consecutive patients who had high grade coronary stenosis or occlusion on their angiograms.</p> <p>Results</p> <p>Mean age was 61 years and 75% were males. Of the 171 patients 88 (51%) had well developed collaterals (grades of 2 or 3) whereas 83 (49%) had impaired collateral development (grades of 0 or 1). Patients with poor collaterals were significantly more likely to have diabetes (<it>p </it>= 0.001), but less likely to have used statins (<it>p </it>= 0.083). FMD measurements were not significantly different among good and poor collateral groups (11.5 ± 5.6 vs. 10.4 ± 6.2% respectively, <it>p </it>= 0.214). Nitroglycerin mediated dilation was also similar (13.4 ± 5.9 vs. 12.8 ± 6.5%, <it>p </it>= 0.521).</p> <p>Conclusion</p> <p>No significant association was found between the extent of angiographically visible coronary collaterals and systemic endothelial function assessed by FMD of the brachial artery.</p
Diagnostic value of acustic radiation force impulse imaging in the assessment of salivary gland involvement in primary Sjogren's sydrome
Aims: The aim of this study is to investigate the diagnostic value of Acoustic Radiation Force Impulse (ARFI) imaging in the assessment of salivary gland involvement in primary Sjogren's syndrome (pSS). Material and methods: Twenty five patients with pSS and 25 healthy volunteers were included. First, echostructures and the thickness of the submandibular and parotid glands were evaluated by B-mode ultrasonography. Then, ARFI imaging with Virtual Touch Quantification (R) was performed. Ten independent shear wave velocity measurements were taken from each gland. Finally, the mean shear wave velocity (SWV) values were calculated, and used for further analysis. Results: The mean SWV values of parotid and submandibular glands were significantly higher in the pSS patients than in the healthy control group (p 0.005). Conclusions: Our findings indicate that ARFI imaging may provide a non-invasive, simple and fast means of assessment of glandular impairment as an alternative test when other salivary gland tests are inconclusive or cannot be performed. ARFI may be a valuable adjunct for the clinical diagnosis of pSS
Interobserver and intermethod variability in data interpretation of breast strain elastography in suspicious breast lesions
Background/aim: Strain elastography has the disadvantage of being operator-dependent. Interobserver variability is observed during image acquisition and interpretation. This study aimed to analyze the interobserver and intermethod variability of strain elastography in image interpretation and evaluate the diagnostic performance combining elasticity score and strain ratio with ultrasonography
Value of shear wave elastography by virtual touch tissue imaging quantification in patients with diffuse thyroid gland pathology
Background/aim: This study was performed to assess the diagnostic accuracy of shear wave elastography by virtual touch tissue imaging quantification in patients with diffuse thyroid gland pathology and to differentiate Graves' disease from Hashimoto's thyroiditis.
Materials and methods: Thirty patients with Hashimoto's thyroiditis and 22 patients with Graves' disease were evaluated with conventional ultrasonography and shear wave elastography by virtual touch tissue imaging quantification. Thirty healthy participants formed the control group. Ten elastographic measurements of each thyroid lobe were performed in all three study groups. The mean shear wave velocity was calculated and compared between the patients and controls.
Results: The mean shear wave velocity of the controls (1.92 +/- 0.14 m/s) was significantly lower than that of the patients with Graves' disease (2.71 +/- 0.22 m/s) and Hashimoto's thyroiditis (2.50 +/- 0.20 m/s). Patients with Graves' disease had significantly higher shear wave velocities than those with Hashimoto's thyroiditis (P < 0.001).
Conclusion: Shear wave elastography by virtual touch tissue imaging quantification can be used to discriminate a normal thyroid gland from diffuse thyroid gland pathology after conventional sonography and may assist in the diagnosis of Graves' disease and Hashimoto's thyroiditis