2,469 research outputs found

    Array concepts for solid-state and vacuum microelectronics millimeter-wave generation

    Get PDF
    The authors have proposed that the increasing demand for contact watt-level coherent sources in the millimeter- and submillimeter-wave region can be satisfied by fabricating two-dimensional grids loaded with oscillators and multipliers for quasi-optical coherent spatial combining of the outputs of large numbers of low-power devices. This was first demonstrated through the successful fabrication of monolithic arrays with 2000 Schottky diodes. Watt-level power outputs were obtained in doubling to 66 GHz. In addition, a simple transmission-line model was verified with a quasi-optical reflectometer that measured the array impedance. This multiplier array work is being extended to novel tripler configurations using blocking barrier devices. The technique has also been extended to oscillator configurations where the grid structure is loaded with negative-resistance devices. This was first demonstrated using Gunn devices. More recently, a 25-element MESFET grid oscillating at 10 GHz exhibited power combining and self-locking. Currently, this approach is being extended to a 100-element monolithic array of Gunn diodes. This same approach should be applicable to planar vacuum electron devices such as the submillimeter-wave BWO (backward wave oscillator) and vacuum FET

    Imaging Polarimeter Arrays for Near-Millimeter Waves

    Get PDF
    An integrated-circuit antenna array has been developed that images both polarization and intensity. The array consists of a row of antennas that lean alternately left and right, creating two interlaced sub-arrays that respond to different polarizations. The arrays and the bismuth bolometer detectors are made by a photoresist shadowing technique that requires only one photolithographic mask. The array has measured polarization at a wavelength of 800 µm with an absolute accuracy of 0.8° and a relative precision of 7 arc min. and has demonstrated nearly diffraction-Iimited resolutiort of a 20° step in polarization

    Millimeter-wave diode-grid phase shifters

    Get PDF
    Monolithic diode grids have been fabricated on 2-cm square gallium-arsenide wafers with 1600 Schottky-barrier varactor diodes. Shorted diodes are detected with a liquid-crystal technique, and the bad diodes are removed with an ultrasonic probe. A small-aperture reflectometer that uses wavefront division interference was developed to measure the reflection coefficient of the grids. A Phase shift of 70° with a 7-dB loss was obtained at 93 GHz when the bias on the diode grid was changed from -3 V to 1 V. A simple transmission-line grid model, together with the measured low-frequency parameters for the diodes, was shown to predict the measured performance over the entire capacitive bias range of the diodes, as well as over the complete reactive tuning range provided by a reflector behind the grid, and over a wide range of frequencies form 33 GHz to 141 GHz. This shows that the transmission-line model and the measured low-frequency diode parameters can be used to design an electronic beam-steering array and to predict its performance. An electronic beam-steering array made of a pair of grids using state-of-the-art diodes with 5-Ω series resistances would have a loss of 1.4 dB at 90 GHz

    Energy and directional signatures for plane quantized gravity waves

    Get PDF
    Solutions are constructed to the quantum constraints for planar gravity (fields dependent on z and t only) in the Ashtekar complex connection formalism. A number of operators are constructed and applied to the solutions. These include the familiar ADM energy and area operators, as well as new operators sensitive to directionality (z+ct vs. z-ct dependence). The directionality operators are quantum analogs of the classical constraints proposed for unidirectional plane waves by Bondi, Pirani, and Robinson (BPR). It is argued that the quantum BPR constraints will predict unidirectionality reliably only for solutions which are semiclassical in a certain sense. The ADM energy and area operators are likely to have imaginary eigenvalues, unless one either shifts to a real connection, or allows the connection to occur other than in a holonomy. In classical theory, the area can evolve to zero. A quantum mechanical mechanism is proposed which would prevent this collapse.Comment: 54 pages; LaTe

    Millimeter-Wave Diode-Grid Frequency Doubler

    Get PDF
    Monolithic diode grid were fabricated on 2-cm^2 gallium-arsenide wafers in a proof-of-principle test of a quasi-optical varactor millimeter-wave frequency multiplier array concept. An equivalent circuit model based on a transmission-line analysis of plane wave illumination was applied to predict the array performance. The doubler experiments were performed under far-field illumination conditions. A second-harmonic conversion efficiency of 9.5% and output powers of 0.5 W were achieved at 66 GHz when the diode grid was pumped with a pulsed source at 33 GHz. This grid had 760 Schottky-barrier varactor diodes. The average series resistance was 27 Ω, the minimum capacitance was 18 fF at a reverse breakdown voltage of -3 V. The measurements indicate that the diode grid is a feasible device for generating watt-level powers at millimeter frequencies and that substantial improvement is possible by improving the diode breakdown voltage

    Mutagenicity testing of 9-N-substituted adenines and their N-oxidation products.

    Get PDF
    Adenine together with certain 9-N-substituted derivatives such as 9-methyl, 9-benzyl, 9-benzhydryl, and 9-trityl were tested against Salmonella typhimurium strains TA97, TA98, and TA100 in the absence and presence of rat hepatic S9 prepared from Aroclor 1254 pretreated rats. All compounds were positive toward TA98 in the presence of the metabolic activating system, whereas they all lacked mutagenic activity in the absence of S9, and toward TA97 and TA100 with or without S9 when tested at 100 ng/plate. A similar pattern was observed for the corresponding 1-N-oxides. 6-Hydroxylaminopurine was not mutagenic toward TA100 at 100 ng/plate, whereas it was toxic toward TA97 and TA98 at this level. When tested at 1 ng/plate, hydroxylaminopurine was still toxic to TA98 but produced twice the spontaneous reversion rate to TA97 without metabolic activation. Surprisingly, 9-methyl-6-hydroxylaminopurine was only active toward TA98 in the presence of S9, whereas 9-benzyl-6-hydroxylaminopurine was highly active toward TA97 and TA100 in the absence of S9 and even more active in the presence of S9. This compound was inactive toward TA98 in the absence of S9. The results generally support the concept that nuclear N-oxidation of aminoazaheterocycles is a detoxication process, whereas N-hydroxylation of the exo amino group is a toxication reaction

    Age and Prostate-Specific Antigen Level Prior to Diagnosis Predict Risk of Death from Prostate Cancer.

    Get PDF
    A single early prostate-specific antigen (PSA) level has been correlated with a higher likelihood of prostate cancer diagnosis and death in younger men. PSA testing in older men has been considered of limited utility. We evaluated prostate cancer death in relation to age and PSA level immediately prior to prostate cancer diagnosis. Using the Veterans Affairs database, we identified 230,081 men aged 50-89 years diagnosed with prostate cancer and at least one prior PSA test between 1999 and 2009. Prostate cancer-specific death over time was calculated for patients stratified by age group (e.g., 50-59 years, through 80-89 years) and PSA range at diagnosis (10 ranges) using Kaplan-Meier methods. Risk of 10-year prostate cancer mortality across age and PSA was compared using log-rank tests with a Bonferroni adjustment for multiple testing. 10.5% of men diagnosed with prostate cancer died of cancer during the 10-year study period (mean follow-up = 3.7 years). Higher PSA values prior to diagnosis predict a higher risk of death in all age groups (p < 0.0001). Within the same PSA range, older age groups are at increased risk for death from prostate cancer (p < 0.0001). For PSA of 7-10 ng/mL, cancer-specific death, 10 years after diagnosis, increased from 7% for age 50-59 years to 51% for age 80-89 years. Men older than 70 years are more likely to die of prostate cancer at any PSA level than younger men, suggesting prostate cancer remains a significant problem among older men (even those aged 80+) and deserves additional study

    Cardio-metabolic impact of changing sitting, standing, and stepping in the workplace

    Get PDF
    According to cross-sectional and acute experimental evidence, reducing sitting time should improve cardio-metabolic health risk biomarkers. Furthermore, the improvements obtained may depend on whether sitting is replaced with standing or ambulatory activities. Based on data from the Stand Up Victoria multi-component workplace intervention, we examined this issue using compositional data analysis - a method that can examine and compare all activity changes simultaneously.Participants receiving the intervention (n=136 ≥0.6 full-time equivalent desk-based workers, 65% women, mean±SD age=44.6 ±9.1 years from seven worksites) were asked to improve whole-of-day activity by standing up, sitting less and moving more. Their changes in the composition of daily waking hours (activPAL-assessed sitting, standing, stepping) were quantified, then tested for associations with concurrent changes in cardio-metabolic risk (CMR) scores and 14 biomarkers concerning body composition, glucose, insulin and lipid metabolism. Analyses were by mixed models, accounting for clustering (3 months, n=105-120; 12 months, n=80-97).Sitting reduction was significantly (

    Sitting Less and Moving More: Implications for Hypertension.

    Get PDF
    Through a hypertension lens, this review focuses on the serious health implications and potential counter-measures for the high volumes of uninterrupted sitting that characterises modern lifestyles. Reducing and breaking up sitting may represent a viable clinical and population health strategy to reduce blood pressure and related cardiovascular risk factors, which in contrast to moderate-vigorous physical activity, may have significant potential for widespread uptake. This review synthesises findings on the specific relationships of sedentary behaviour with BP - which primarily are from observational and acute experimental studies - including a discussion on the relevant cardiovascular mechanisms. It also considers what will need to be better understood as a basis for evidence-based recommendations on sedentary time in the context of BP control, and identify evidence gaps for future research

    Diode-grids for millimeter-wave phase-shifters and frequency doublers

    Get PDF
    Diode-grids have been fabricated on 2-cm square monolithic gallium-arsenide wafers with 1600 Schottky varactor-diodes. A computer-controlled reflectometer that uses a wave-front division interference technique was developed to measure the reflection coefficient of the diode-grids. A 70° phase shift with a 6-dB loss was obtained at 93 GHz when the bias on the diode-grid was changed from -3V to +1V. A second harmonic conversion efficiency of 16% and an output power of 0.5 W was obtained at 66 GHz when the diode-grid was pumped with a pulsed magnetron at 33 GHz
    corecore