4 research outputs found
Review of Clinical Recommendations for Kawasaki Disease/Syndrome
The article presents the detailed key provisions of the clinical recommendations on providing medical care to children with Kawasaki syndrome/illness, developed by the professional association of pediatric specialists β the Union of Pediatricians of Russia. The current data on the prevalence of pathology is presented, the characteristic diagnostic signs of the disease are given that allow to make a diagnosis as soon as possible and immediately appoint a specific treatment. Therapeutic measures carried out in the required volume determine the further prognosis. The comprehensive approach to the management of pediatric patients with this nosology presented in the article will ensure a high level of medical care quality provided to children with Kawasaki syndrome
ΠΠ±Π·ΠΎΡ ΠΊΠ»ΠΈΠ½ΠΈΡΠ΅ΡΠΊΠΈΡ ΡΠ΅ΠΊΠΎΠΌΠ΅Π½Π΄Π°ΡΠΈΠΉ ΠΏΠΎ Π±ΠΎΠ»Π΅Π·Π½ΠΈ/ΡΠΈΠ½Π΄ΡΠΎΠΌΡ ΠΠ°Π²Π°ΡΠ°ΠΊΠΈ
The article presents the detailed key provisions of the clinical recommendations on providing medical care to children with Kawasaki syndrome/illness, developed by the professional association of pediatric specialists β the Union of Pediatricians of Russia. The current data on the prevalence of pathology is presented, the characteristic diagnostic signs of the disease are given that allow to make a diagnosis as soon as possible and immediately appoint a specific treatment. Therapeutic measures carried out in the required volume determine the further prognosis. The comprehensive approach to the management of pediatric patients with this nosology presented in the article will ensure a high level of medical care quality provided to children with Kawasaki syndrome.Π ΡΡΠ°ΡΡΠ΅ ΠΏΠΎΠ΄ΡΠΎΠ±Π½ΠΎ ΠΏΡΠ΅Π΄ΡΡΠ°Π²Π»Π΅Π½Ρ ΠΊΠ»ΡΡΠ΅Π²ΡΠ΅ ΠΏΠΎΠ»ΠΎΠΆΠ΅Π½ΠΈΡ ΠΊΠ»ΠΈΠ½ΠΈΡΠ΅ΡΠΊΠΈΡ
ΡΠ΅ΠΊΠΎΠΌΠ΅Π½Π΄Π°ΡΠΈΠΉ ΠΏΠΎ ΠΎΠΊΠ°Π·Π°Π½ΠΈΡ ΠΌΠ΅Π΄ΠΈΡΠΈΠ½ΡΠΊΠΎΠΉ ΠΏΠΎΠΌΠΎΡΠΈ Π΄Π΅ΡΡΠΌ Ρ ΡΠΈΠ½Π΄ΡΠΎΠΌΠΎΠΌ/Π±ΠΎΠ»Π΅Π·Π½ΡΡ ΠΠ°Π²Π°ΡΠ°ΠΊΠΈ, ΡΠ°Π·ΡΠ°Π±ΠΎΡΠ°Π½Π½ΡΡ
ΠΏΡΠΎΡΠ΅ΡΡΠΈΠΎΠ½Π°Π»ΡΠ½ΠΎΠΉ Π°ΡΡΠΎΡΠΈΠ°ΡΠΈΠ΅ΠΉ Π΄Π΅ΡΡΠΊΠΈΡ
ΡΠΏΠ΅ΡΠΈΠ°Π»ΠΈΡΡΠΎΠ² β Π‘ΠΎΡΠ·ΠΎΠΌ ΠΏΠ΅Π΄ΠΈΠ°ΡΡΠΎΠ² Π ΠΎΡΡΠΈΠΈ. ΠΠ·Π»ΠΎΠΆΠ΅Π½Ρ ΡΠΎΠ²ΡΠ΅ΠΌΠ΅Π½Π½ΡΠ΅ Π΄Π°Π½Π½ΡΠ΅ ΠΎ ΡΠ°ΡΠΏΡΠΎΡΡΡΠ°Π½Π΅Π½Π½ΠΎΡΡΠΈ ΠΏΠ°ΡΠΎΠ»ΠΎΠ³ΠΈΠΈ, ΠΏΡΠΈΠ²Π΅Π΄Π΅Π½Ρ Ρ
Π°ΡΠ°ΠΊΡΠ΅ΡΠ½ΡΠ΅ Π΄ΠΈΠ°Π³Π½ΠΎΡΡΠΈΡΠ΅ΡΠΊΠΈΠ΅ ΠΏΡΠΈΠ·Π½Π°ΠΊΠΈ Π±ΠΎΠ»Π΅Π·Π½ΠΈ, ΠΏΠΎΠ·Π²ΠΎΠ»ΡΡΡΠΈΠ΅ ΠΌΠ°ΠΊΡΠΈΠΌΠ°Π»ΡΠ½ΠΎ ΡΠ²ΠΎΠ΅Π²ΡΠ΅ΠΌΠ΅Π½Π½ΠΎ ΡΡΡΠ°Π½ΠΎΠ²ΠΈΡΡ Π΄ΠΈΠ°Π³Π½ΠΎΠ· ΠΈ Π½Π΅Π·Π°ΠΌΠ΅Π΄Π»ΠΈΡΠ΅Π»ΡΠ½ΠΎ Π½Π°Π·Π½Π°ΡΠΈΡΡ ΡΠΏΠ΅ΡΠΈΡΠΈΡΠ΅ΡΠΊΠΎΠ΅ Π»Π΅ΡΠ΅Π½ΠΈΠ΅. Π’Π΅ΡΠ°ΠΏΠ΅Π²ΡΠΈΡΠ΅ΡΠΊΠΈΠ΅ ΠΌΠ΅ΡΠΎΠΏΡΠΈΡΡΠΈΡ, ΠΏΡΠΎΠ²Π΅Π΄Π΅Π½Π½ΡΠ΅ Π² Π½Π΅ΠΎΠ±Ρ
ΠΎΠ΄ΠΈΠΌΠΎΠΌ ΠΎΠ±ΡΠ΅ΠΌΠ΅, ΠΎΠΏΡΠ΅Π΄Π΅Π»ΡΡΡ Π΄Π°Π»ΡΠ½Π΅ΠΉΡΠΈΠΉ ΠΏΡΠΎΠ³Π½ΠΎΠ·. ΠΡΠ΅Π΄ΡΡΠ°Π²Π»Π΅Π½Π½ΡΠΉ Π² ΡΡΠ°ΡΡΠ΅ ΠΊΠΎΠΌΠΏΠ»Π΅ΠΊΡΠ½ΡΠΉ ΠΏΠΎΠ΄Ρ
ΠΎΠ΄ ΠΊ Π²Π΅Π΄Π΅Π½ΠΈΡ ΠΏΠ°ΡΠΈΠ΅Π½ΡΠΎΠ² Π΄Π΅ΡΡΠΊΠΎΠ³ΠΎ Π²ΠΎΠ·ΡΠ°ΡΡΠ° Ρ Π΄Π°Π½Π½ΠΎΠΉ Π½ΠΎΠ·ΠΎΠ»ΠΎΠ³ΠΈΠ΅ΠΉ ΠΏΠΎΠ·Π²ΠΎΠ»ΠΈΡ ΠΎΠ±Π΅ΡΠΏΠ΅ΡΠΈΡΡ Π²ΡΡΠΎΠΊΠΈΠΉ ΡΡΠΎΠ²Π΅Π½Ρ ΠΊΠ°ΡΠ΅ΡΡΠ²Π° ΠΎΠΊΠ°Π·ΡΠ²Π°Π΅ΠΌΠΎΠΉ ΠΌΠ΅Π΄ΠΈΡΠΈΠ½ΡΠΊΠΎΠΉ ΠΏΠΎΠΌΠΎΡΠΈ Π΄Π΅ΡΡΠΌ Ρ ΡΠΈΠ½Π΄ΡΠΎΠΌΠΎΠΌ ΠΠ°Π²Π°ΡΠ°ΠΊΠΈ
Sorption of Copper (II) from Aqueous Solutions on Complexing Ion Exchangers and Determination of Copper by Diffuse Reflectance Spectroscopy
ΠΠ°Π½Π½Π°Ρ ΡΠ°Π±ΠΎΡΠ° ΠΏΠΎΡΠ²ΡΡΠ΅Π½Π° ΡΠΎΡΠ±ΡΠΈΠΎΠ½Π½ΠΎΠΌΡ ΠΊΠΎΠ½ΡΠ΅Π½ΡΡΠΈΡΠΎΠ²Π°Π½ΠΈΡ ΠΌΠ΅Π΄ΠΈ (II) ΠΈΠ· ΡΠ°Π·Π»ΠΈΡΠ½ΡΡ
ΡΠ°ΡΡΠ²ΠΎΡΠΎΠ² Π½Π° ΡΡΠ΄Π΅ ΠΊΠΎΠΌΠΏΠ»Π΅ΠΊΡΠΎΠΎΠ±ΡΠ°Π·ΡΡΡΠΈΡ
ΠΈΠΎΠ½ΠΈΡΠΎΠ² ΠΈ ΠΏΠΎΡΠ»Π΅Π΄ΡΡΡΠ΅ΠΌΡ ΠΎΠΏΡΠ΅Π΄Π΅Π»Π΅Π½ΠΈΡ Cu (II) Π² ΡΠ°Π·Π΅ Π°ΠΌΡΠΎΡΠ΅ΡΠ½ΠΎΠ³ΠΎ ΠΈΠΎΠ½ΠΈΡΠ° ΠΠΠ€-2Π’ ΠΌΠ°ΠΊΡΠΎΡΠ΅ΡΡΠ°ΡΠΎΠΉ ΡΡΡΡΠΊΡΡΡΡ ΡΠΏΠ΅ΠΊΡΡΠΎΡΠΊΠΎΠΏΠΈΠ΅ΠΉ Π΄ΠΈΡΡΡΠ·Π½ΠΎΠ³ΠΎ ΠΎΡΡΠ°ΠΆΠ΅Π½ΠΈΡ. ΠΡΡΠ»Π΅Π΄ΠΎΠ²Π°Π½Ρ ΡΠΎΡΠ±ΡΠΈΠΎΠ½Π½ΡΠ΅ ΡΠ²ΠΎΠΉΡΡΠ²Π° ΠΈΠΎΠ½ΠΈΡΠΎΠ² ΠΈ ΡΠ°ΡΡΡΠΈΡΠ°Π½Ρ ΠΊΠ°ΠΆΡΡΠΈΠ΅ΡΡ ΠΊΠΎΠ½ΡΡΠ°Π½ΡΡ ΡΡΡΠΎΠΉΡΠΈΠ²ΠΎΡΡΠΈ ΠΊΠΎΠΌΠΏΠ»Π΅ΠΊΡΠΎΠ² ΠΌΠ΅Π΄ΠΈ Π² ΡΠ°Π·Π΅ ΠΈΠΎΠ½ΠΎΠΎΠ±ΠΌΠ΅Π½Π½ΠΈΠΊΠΎΠ². ΠΡΠ΅Π΄Π»ΠΎΠΆΠ΅Π½ ΡΠΎΡΠ±ΡΠΈΠΎΠ½Π½ΠΎ-ΡΠΏΠ΅ΠΊΡΡΠΎΡΠΊΠΎΠΏΠΈΡΠ΅ΡΠΊΠΈΠΉ ΠΌΠ΅ΡΠΎΠ΄ ΠΎΠΏΡΠ΅Π΄Π΅Π»Π΅Π½ΠΈΡ Cu (II) Π² Π²ΠΎΠ΄Π½ΡΡ
ΡΠ°ΡΡΠ²ΠΎΡΠ°Ρ
. ΠΡΠ°Π΄ΡΠΈΡΠΎΠ²ΠΎΡΠ½ΡΠΉ Π³ΡΠ°ΡΠΈΠΊ Π»ΠΈΠ½Π΅Π΅Π½ Π² ΠΈΠ½ΡΠ΅ΡΠ²Π°Π»Π΅ ΠΊΠΎΠ½ΡΠ΅Π½ΡΡΠ°ΡΠΈΠΉ 0.05 - 3.0 ΠΌΠ³/Π» (ΠΎΠ±ΡΠ΅ΠΌ ΠΏΡΠΎΠ±Ρ 25.0 ΠΌΠ»), ΠΏΡΠ΅Π΄Π΅Π» ΠΎΠ±Π½Π°ΡΡΠΆΠ΅Π½ΠΈΡ ΡΠΎΡΡΠ°Π²Π»ΡΠ΅Ρ 0.03 ΠΌΠΊΠ³/ΠΌΠ». ΠΡΠΈΡΡΡΡΡΠ²ΠΈΠ΅ Ni (II), Co (II), Cr (III), Fe (II,III), Zn (II), Π° ΡΠ°ΠΊΠΆΠ΅ ΠΈΠΎΠ½ΠΎΠ² C2O42- ΠΈ PO43- (100-ΠΊΡΠ°ΡΠ½ΡΠ΅ ΠΈΠ·Π±ΡΡΠΊΠΈ) Π½Π΅ ΠΌΠ΅ΡΠ°Π΅Ρ ΠΎΠΏΡΠ΅Π΄Π΅Π»Π΅Π½ΠΈΡ Cu (II).The present paper is devoted to sorption concentration of copper (II) from different solutions on a number of complexing ion exchangers and subsequent determination of Cu (II) in a phase of amphoteric ion exchanger AMF-2T of macroreticular structure by diffuse reflectance spectroscopy. The sorption properties of the sorbents were investigated. The apparent stability constants for copper complexes in ion exchanger phase were calculated. The sorption-spectroscopic method is proposed for Cu (II) determination in aqueous solutions. The calibration curve is linear at concentration range 0.05 - 3.0 mg/L (sample volume is 25.0 mL) and the detection limit is 0.03 ΞΌg/mL. The presence of Ni (II), Co (II), Cr (III), Fe (II,III), Zn (II) as well as C2O42-and PO43-(100-fold excesses) does not hinder the determination of Cu (II)
Sorption of Copper (II) from Aqueous Solutions on Complexing Ion Exchangers and Determination of Copper by Diffuse Reflectance Spectroscopy
ΠΠ°Π½Π½Π°Ρ ΡΠ°Π±ΠΎΡΠ° ΠΏΠΎΡΠ²ΡΡΠ΅Π½Π° ΡΠΎΡΠ±ΡΠΈΠΎΠ½Π½ΠΎΠΌΡ ΠΊΠΎΠ½ΡΠ΅Π½ΡΡΠΈΡΠΎΠ²Π°Π½ΠΈΡ ΠΌΠ΅Π΄ΠΈ (II) ΠΈΠ· ΡΠ°Π·Π»ΠΈΡΠ½ΡΡ
ΡΠ°ΡΡΠ²ΠΎΡΠΎΠ² Π½Π° ΡΡΠ΄Π΅ ΠΊΠΎΠΌΠΏΠ»Π΅ΠΊΡΠΎΠΎΠ±ΡΠ°Π·ΡΡΡΠΈΡ
ΠΈΠΎΠ½ΠΈΡΠΎΠ² ΠΈ ΠΏΠΎΡΠ»Π΅Π΄ΡΡΡΠ΅ΠΌΡ ΠΎΠΏΡΠ΅Π΄Π΅Π»Π΅Π½ΠΈΡ Cu (II) Π² ΡΠ°Π·Π΅ Π°ΠΌΡΠΎΡΠ΅ΡΠ½ΠΎΠ³ΠΎ ΠΈΠΎΠ½ΠΈΡΠ° ΠΠΠ€-2Π’ ΠΌΠ°ΠΊΡΠΎΡΠ΅ΡΡΠ°ΡΠΎΠΉ ΡΡΡΡΠΊΡΡΡΡ ΡΠΏΠ΅ΠΊΡΡΠΎΡΠΊΠΎΠΏΠΈΠ΅ΠΉ Π΄ΠΈΡΡΡΠ·Π½ΠΎΠ³ΠΎ ΠΎΡΡΠ°ΠΆΠ΅Π½ΠΈΡ. ΠΡΡΠ»Π΅Π΄ΠΎΠ²Π°Π½Ρ ΡΠΎΡΠ±ΡΠΈΠΎΠ½Π½ΡΠ΅ ΡΠ²ΠΎΠΉΡΡΠ²Π° ΠΈΠΎΠ½ΠΈΡΠΎΠ² ΠΈ ΡΠ°ΡΡΡΠΈΡΠ°Π½Ρ ΠΊΠ°ΠΆΡΡΠΈΠ΅ΡΡ ΠΊΠΎΠ½ΡΡΠ°Π½ΡΡ ΡΡΡΠΎΠΉΡΠΈΠ²ΠΎΡΡΠΈ ΠΊΠΎΠΌΠΏΠ»Π΅ΠΊΡΠΎΠ² ΠΌΠ΅Π΄ΠΈ Π² ΡΠ°Π·Π΅ ΠΈΠΎΠ½ΠΎΠΎΠ±ΠΌΠ΅Π½Π½ΠΈΠΊΠΎΠ². ΠΡΠ΅Π΄Π»ΠΎΠΆΠ΅Π½ ΡΠΎΡΠ±ΡΠΈΠΎΠ½Π½ΠΎ-ΡΠΏΠ΅ΠΊΡΡΠΎΡΠΊΠΎΠΏΠΈΡΠ΅ΡΠΊΠΈΠΉ ΠΌΠ΅ΡΠΎΠ΄ ΠΎΠΏΡΠ΅Π΄Π΅Π»Π΅Π½ΠΈΡ Cu (II) Π² Π²ΠΎΠ΄Π½ΡΡ
ΡΠ°ΡΡΠ²ΠΎΡΠ°Ρ
. ΠΡΠ°Π΄ΡΠΈΡΠΎΠ²ΠΎΡΠ½ΡΠΉ Π³ΡΠ°ΡΠΈΠΊ Π»ΠΈΠ½Π΅Π΅Π½ Π² ΠΈΠ½ΡΠ΅ΡΠ²Π°Π»Π΅ ΠΊΠΎΠ½ΡΠ΅Π½ΡΡΠ°ΡΠΈΠΉ 0.05 - 3.0 ΠΌΠ³/Π» (ΠΎΠ±ΡΠ΅ΠΌ ΠΏΡΠΎΠ±Ρ 25.0 ΠΌΠ»), ΠΏΡΠ΅Π΄Π΅Π» ΠΎΠ±Π½Π°ΡΡΠΆΠ΅Π½ΠΈΡ ΡΠΎΡΡΠ°Π²Π»ΡΠ΅Ρ 0.03 ΠΌΠΊΠ³/ΠΌΠ». ΠΡΠΈΡΡΡΡΡΠ²ΠΈΠ΅ Ni (II), Co (II), Cr (III), Fe (II,III), Zn (II), Π° ΡΠ°ΠΊΠΆΠ΅ ΠΈΠΎΠ½ΠΎΠ² C2O42- ΠΈ PO43- (100-ΠΊΡΠ°ΡΠ½ΡΠ΅ ΠΈΠ·Π±ΡΡΠΊΠΈ) Π½Π΅ ΠΌΠ΅ΡΠ°Π΅Ρ ΠΎΠΏΡΠ΅Π΄Π΅Π»Π΅Π½ΠΈΡ Cu (II).The present paper is devoted to sorption concentration of copper (II) from different solutions on a number of complexing ion exchangers and subsequent determination of Cu (II) in a phase of amphoteric ion exchanger AMF-2T of macroreticular structure by diffuse reflectance spectroscopy. The sorption properties of the sorbents were investigated. The apparent stability constants for copper complexes in ion exchanger phase were calculated. The sorption-spectroscopic method is proposed for Cu (II) determination in aqueous solutions. The calibration curve is linear at concentration range 0.05 - 3.0 mg/L (sample volume is 25.0 mL) and the detection limit is 0.03 ΞΌg/mL. The presence of Ni (II), Co (II), Cr (III), Fe (II,III), Zn (II) as well as C2O42-and PO43-(100-fold excesses) does not hinder the determination of Cu (II)