131 research outputs found

    Search for a stochastic background of 100-MHz gravitational waves with laser interferometers

    Full text link
    This letter reports the results of a search for a stochastic background of gravitational waves (GW) at 100 MHz by laser interferometry. We have developed a GW detector, which is a pair of 75-cm baseline synchronous recycling (resonant recycling) interferometers. Each interferometer has a strain sensitivity of ~ 10^{-16} Hz^{-1/2} at 100 MHz. By cross-correlating the outputs of the two interferometers within 1000 seconds, we found h_{100}^2 Omega_{gw} < 6 times 10^{25} to be an upper limit on the energy density spectrum of the GW background in a 2-kHz bandwidth around 100 MHz, where a flat spectrum is assumed.Comment: Accepted by Phys.Rev.Lett.; 10 pages, 4 figure

    Relevance of the Core 70 and IL-28B polymorphism and response-guided therapy of peginterferon alfa-2a ± ribavirin for chronic hepatitis C of Genotype 1b: a multicenter randomized trial, ReGIT-J study

    Get PDF
    BACKGROUND: We conducted a multicenter randomized clinical trial to determine the optimal treatment strategy against chronic hepatitis C virus (HCV) with genotype 1b and a high viral load (G1b/high). METHODS: The study subjects included 153 patients with G1b/high. Patients were initially treated with PEG-IFNα-2a alone and then randomly assigned to receive different treatment regimens. Ribavirin (RBV) was administered to all patients with HCV RNA at week 4. Patients negative for HCV RNA at week 4 were randomly assigned to receive PEG-IFNα-2a (group A) or PEG-IFNα-2a/RBV (group B). Patients who showed HCV RNA at week 4 but were negative at week 12 were randomly assigned to receive weekly PEG-IFNα-2a (group C) or biweekly therapy (group D). Patients who showed HCV RNA at week 12 but were negative at week 24 were randomly assigned to receive PEG-IFNα-2a/RBV (group E) or PEG-IFNα-2a/RBV/fluvastatin (group F). RESULTS: Overall, the rate of sustained virological response (SVR) was 46 % (70/153). The total SVR rate in the group (A, D, and F) of response-guided therapy was significantly higher than that in the group (B, C, and E) of conventional therapy [70 % (38/54) versus 52 % (32/61), p = 0.049]. Although IL28-B polymorphism and Core 70 mutation were significantly associated with efficacy, patients with rapid virological response (RVR) and complete early virological response (cEVR) achieved high SVR rates regardless of their status of IL-28B polymorphism and Core 70 mutation. CONCLUSION: In addition to knowing the IL-28B polymorphism and Core 70 mutation status, understanding the likelihood of virological response during treatment is critical in determining the appropriate treatment strategy

    Optimal Location of Two Laser-interferometric Detectors for Gravitational Wave Backgrounds at 100 MHz

    Full text link
    Recently, observational searches for gravitational wave background (GWB) have been developed and given constraints on the energy density of GWB in a broad range of frequencies. These constraints have already resulted in the rejection of some theoretical models of relatively large GWB spectra. However, at 100 MHz, there is no strict upper limit from direct observation, though an indirect limit exists due to He4 abundance due to big-bang nucleosynthesis. In our previous paper, we investigated the detector designs that can effectively respond to GW at high frequencies, where the wavelength of GW is comparable to the size of a detector, and found that the configuration, a so-called synchronous-recycling interferometer is best at these sensitivity. In this paper, we investigated the optimal location of two synchronous-recycling interferometers and derived their cross-correlation sensitivity to GWB. We found that the sensitivity is nearly optimized and hardly changed if two coaligned detectors are located within a range 0.2 m, and that the sensitivity achievable in an experiment is far below compared with the constraint previously obtained in experiments.Comment: 17 pages, 6 figure

    Immunological Microenvironment Predicts the Survival of the Patients with Hepatocellular Carcinoma Treated with Anti-PD-1 Antibody

    Get PDF
    Introduction: Although immune checkpoint inhibitors (ICIs) have been considered as promising agents for the treatment of advanced hepatocellular carcinoma (HCC), previous clinical trials revealed that the response to anti-programmed cell death protein 1 (anti-PD-1) monotherapy was as low as 20%. Identifying subgroups that respond well to ICIs is clinically important. Here, we studied the prognostic factors for anti-PD-1 antibody treatment based on the molecular and immunological features of HCC. Methods: Patients who were administered anti-PD1 antibody for advanced HCC at Kindai University Hospital were included. Clinicopathological backgrounds and antitumor responses were examined in 34 cases where tumor tissues before treatment were available. Transcriptome analysis was performed using 40 HCC samples obtained from surgical resection, and immune status was compared between 20 HCCs with activating mutations in β-catenin and those without the mutations using transcriptome-based immunogram. Results: Univariate analysis showed that the disease control rate was significantly better in patients with α-fetoprotein &#x3c; 400 ng/mL, negative for β-catenin/glutamate synthetase (GS) staining, high combined positive score (CPS) of programmed death-ligand 1 (PD-L1), and increased infiltration of CD8+ cells in tumor tissues. Among them, negative staining of β-catenin/GS, CPS of PD-L1 ≥ 1, and high degree of CD8+ tumor-infiltrating lymphocytes (TILs) were significantly associated with longer survival in both progression-free survival (PFS) and overall survival (OS). The combination of these factors well stratified the survival of the patients on anti-PD-1 antibody in both PFS and OS (p &#x3c; 0.0001 and p = 0.0048 for PFS and OS, respectively). In addition, the immunogram revealed that tumor-carrying mutations in β-catenin showed downregulation of immune-related genes, especially in those related to priming and activation by dendritic cells, interferon-γ response, inhibitory molecules, and regulatory T cells. Discussion/Conclusion: The combined score including Wnt/β-catenin activation, CPS of PD-L1, and degree of CD8+ TILs in HCC is informative for predicting the response to ICI in HCC cases. Constitutive activation of β-catenin can induce an immune cold phenotype with downregulation of immune-related genes, and immunohistochemistry-based evaluation is beneficial for identifying the subgroup that shows a good response to ICI

    Bispectral index-guided propofol sedation during endoscopic ultrasonography

    Get PDF
    Background/Aims Bispectral index (BIS) monitors process and display electroencephalographic data are used to assess the depth of anesthesia. This study retrospectively evaluated the usefulness of BIS monitoring during endoscopic ultrasonography (EUS). Methods This study included 725 consecutive patients who underwent EUS under sedation with propofol. BIS monitoring was used in 364 patients and was not used in 361. The following parameters were evaluated: (1) median dose of propofol; (2) respiratory and circulatory depression; (3) occurrence of body movements; (4) awakening score >8 at the time; and (5) awakening score 2 hours after leaving the endoscopy room. Results The BIS group received a significantly lower median dose of propofol than the non-BIS group (159.2 mg vs. 167.5 mg; p=0.015) in all age groups. For patients aged ≥75 years, the reduction in heart rate was significantly lower in the BIS group than in the non-BIS group (1.2% vs. 9.1%; p=0.023). Moreover, the occurrence of body movements was markedly lower in the BIS group than in the non-BIS group (8.5% vs. 39.4%; p<0.001). Conclusions During EUS examination, BIS monitoring is useful for maintaining a constant depth of anesthesia, especially in patients 75 years of age or older

    Impact of Baseline ALBI Grade on the Outcomes of Hepatocellular Carcinoma Patients Treated with Lenvatinib: A Multicenter Study

    Get PDF
    Background: This study investigated the impact of baseline liver function according to the Child–Pugh score and ALBI (albumin-bilirubin) grade on the outcomes of patients with unresectable hepatocellular carcinoma treated with lenvatinib. Methods: A total of 82 lenvatinib treated patients were included. The correlations of baseline liver function according to the Child–Pugh score and ALBI grade with treatment outcomes, including objective response rate per mRECIST (modified Response Evaluation Criteria in the Solid Tumor), time to treatment failure, treatment duration, and likelihood of treatment discontinuation due to adverse events, were assessed in patients with hepatocellular carcinoma treated with lenvatinib. Patients were divided into four groups: (1) Child–Pugh score 5 and ALBI grade 1 (group 1), (2) Child–Pugh score 5 and ALBI grade 2 (group 2), (3) Child–Pugh score 6 (group 3), and (4) Child–Pugh score ≥7 (group 4). Univariate and multivariate analyses were performed to identify the factors contributing to the objective response rate and likelihood of discontinuation due to adverse events. Results: Among the 82 patients analyzed, group 1 had the highest objective response rate (57.1%) and the lowest likelihood of treatment discontinuation because of adverse events (11.1%) among the four groups (p &lt; 0.05 and p &lt; 0.05). Multivariate analysis identified ALBI grade 1 and baseline AFP level &lt;200 ng/mL as the significant predictors of a high objective response rate (p &lt; 0.05 and p &lt; 0.01), and confirmed that patients with ALBI grade 1 had the lowest probability of treatment discontinuation due to adverse events (p &lt; 0.01). Conclusions: Patients with Child–Pugh score of 5 and ALBI grade 1 predicted a higher response rate and lower treatment discontinuation due to adverse events by lenvatinib treatment

    The Japanese space gravitational wave antenna; DECIGO

    Get PDF
    DECi-hertz Interferometer Gravitational wave Observatory (DECIGO) is the future Japanese space gravitational wave antenna. DECIGO is expected to open a new window of observation for gravitational wave astronomy especially between 0.1 Hz and 10 Hz, revealing various mysteries of the universe such as dark energy, formation mechanism of supermassive black holes, and inflation of the universe. The pre-conceptual design of DECIGO consists of three drag-free spacecraft, whose relative displacements are measured by a differential Fabry– Perot Michelson interferometer. We plan to launch two missions, DECIGO pathfinder and pre- DECIGO first and finally DECIGO in 2024
    • …
    corecore