10 research outputs found

    Output-only Modal Identification of beams with different boundary condition

    Full text link
    Structural Health Monitoring (SHM) evaluates the integrity of a structure by observing its dynamic responses by an array of sensors over time to determine the current health state of the structure. The most important step of SHM is system identification which in civil structures is the identification of modal parameters of structures. Due to numerous limitations of input-output methods, system identification of ambient vibration structures using output-only identification techniques has become a key issue in structural health monitoring and assessment of engineering structures. In this paper, four beams with different boundary conditions and with arbitrary loading have been modeled in finite element software, ANSYS, and the responses (Acceleration of nodes) have been achieved. By using these data and the codes written in MATLAB software, the modal parameters (natural frequencies, mode shapes) of the beams are identified with FDD (frequency Domain Decomposition) and PP (Peak Picking) methods and then justified with the results of input-output method which was determined by frequency relation function (FRF). The results indicate a good agreement between the three methods for determining the dynamic characteristics of beams.Comment: Conference paper. arXiv admin note: substantial text overlap with arXiv:2010.0749

    Attenuation of hemodynamic responses to laryngoscopy and tracheal intubation: Propacetamol versus lidocaine - A randomized clinical trial

    Get PDF
    The purpose of this study is to assess the effects of propacetamol on attenuating hemodynamic responses subsequent laryngoscopy and tracheal intubation compared to lidocaine. In this randomized clinical trial, 62 patients with the American Anesthesiologists Society (ASA) class I/II who required laryngoscopy and tracheal intubation for elective surgery were assigned to receive propacetamol 2 g/I.V./infusion (group P) or lidocaine 1.5 mg/kg (group L) prior to laryngoscopy. Systolic and diastolic blood pressures (SBP, DBP), mean arterial pressure (MAP), and heart rate (HR) were recorded at baseline, before laryngoscopy and within nine minutes after intubation. In both groups P and L, MAP increased after laryngoscopy and the changes were statistically significant (P < 0.001). There were significant changes of HR in both groups after intubation (P < 0.02), but the trend of changes was different between two groups (P < 0.001). In group L, HR increased after intubation and its change was statistically significant within 9 minutes after intubation (P < 0.001), while in group P, HR remained stable after intubation (P = 0.8). Propacetamol 2 gr one hour prior intubation attenuates heart rate responses after laryngoscopy but is not effective to prevent acute alterations in blood pressure after intubation. © 2014 Ali Kord Valeshabad et al

    The Iranian Study of Opium and Cancer (IROPICAN): Rationale, design, and initial findings

    No full text
    Background: The International Agency for Research on Cancer (IARC) recently classified opium use as a Group 1 carcinogen. However, much remains to be studied on the relation between opium and cancer. We designed the Iranian Opium and Cancer (IROPICAN) study to further investigate the association of opium use and cancers of the head and neck, bladder, lung, and colon and rectum. In this paper, we describe the rationale, design, and some initial results of the IROPICAN Study. Methods: The IROPICAN is a multi-center case-control study conducted in 10 provinces of Iran. The cases were all histologically confirmed and the controls were selected from hospital visitors who were free of cancer, were not family members or friends of the cancer patients, and were visiting the hospital for reasons other than their own ailment. The questionnaires included detailed questions on opium use (including age at initiation, duration, frequency, typical amount, and route), and potential confounders, such as tobacco use (e.g., cigarettes, nass and water-pipe), and dietary factors. Biological samples, including blood and saliva, were also collected. Results: The validation and pilot phases showed reasonably good validity, with sensitivities of 70% and 69% for the cases and controls, respectively, in reporting opium use. The results also showed excellent reliability, with intra-class correlation coefficients of 0.96 for ever opium use and 0.88 (95% CI: 0.80, 0.92) for regular opium use. In the main phase, we recruited 3299 cancer cases (99% response rate) and 3477 hospital visitor controls (89% response rate). The proportion of ever-use of opium was 40% among cases and 18% among controls. Conclusion: The IROPICAN study will serve as a major resource in studies addressing the effect of opium on risk of cancers of the head and neck, bladder, lung, and colon and rectum

    Phase Transition Enthalpy Measurements of Organic and Organometallic Compounds. Sublimation, Vaporization and Fusion Enthalpies From 1880 to 2015. Part 1. C 1

    No full text
    corecore