1,268 research outputs found

    Two-dimensional Dirac fermions in a topological insulator: transport in the quantum limit

    Full text link
    Pulsed magnetic fields of up to 55T are used to investigate the transport properties of the topological insulator Bi_2Se_3 in the extreme quantum limit. For samples with a bulk carrier density of n = 2.9\times10^16cm^-3, the lowest Landau level of the bulk 3D Fermi surface is reached by a field of 4T. For fields well beyond this limit, Shubnikov-de Haas oscillations arising from quantization of the 2D surface state are observed, with the \nu =1 Landau level attained by a field of 35T. These measurements reveal the presence of additional oscillations which occur at fields corresponding to simple rational fractions of the integer Landau indices.Comment: 5 pages, 4 figure

    Heavy Flavour Production at Tevatron and Parton Shower Effects

    Get PDF
    We present hadron-level predictions from the Monte Carlo generator Cascade and numerical calculations of charm and beauty production at the Fermilab Tevatron within the framework of the kTk_T-factorization QCD approach. Our consideration is based on the CCFM-evolved unintegrated gluon densities in a proton. The performed analysis covers the total and differential cross sections of open charm and beauty quarks, BB and DD mesons (or rather muons from their semileptonic decays) and the total and differential cross sections of bbˉb \bar b di-jet hadroproduction. We study the theoretical uncertainties of our calculations and investigate the effects coming from parton showers in initial and final states. Our predictions are compared with the recent experimental data taken by the D0 and CDF collaborations. Special attention is put on the specific angular correlations between the final-state particles. We demonstrate that the final state parton shower plays a crucial role in the description of such observables. The decorrelated part of angular separations can be fully described, if the process gggggg^*\rightarrow gg is included.Comment: Fig 8,9 10 replaced, small corrections in text A discussion of the delta phi results is adde

    Mortality and morbidity in community-acquired sepsis in European pediatric intensive care units: a prospective cohort study from the European Childhood Life-threatening Infectious Disease Study (EUCLIDS)

    Get PDF
    BACKGROUND: Sepsis is one of the main reasons for non-elective admission to pediatric intensive care units (PICUs), but little is known about determinants influencing outcome. We characterized children admitted with community-acquired sepsis to European PICUs and studied risk factors for mortality and disability. METHODS: Data were collected within the collaborative Seventh Framework Programme (FP7)-funded EUCLIDS study, which is a prospective multicenter cohort study aiming to evaluate genetic determinants of susceptibility and/or severity in sepsis. This report includes 795 children admitted with community-acquired sepsis to 52 PICUs from seven European countries between July 2012 and January 2016. The primary outcome measure was in-hospital death. Secondary outcome measures were PICU-free days censured at day 28, hospital length of stay, and disability. Independent predictors were identified by multivariate regression analysis. RESULTS: Patients most commonly presented clinically with sepsis without a source (n = 278, 35%), meningitis/encephalitis (n = 182, 23%), or pneumonia (n = 149, 19%). Of 428 (54%) patients with confirmed bacterial infection, Neisseria meningitidis (n = 131, 31%) and Streptococcus pneumoniae (n = 78, 18%) were the main pathogens. Mortality was 6% (51/795), increasing to 10% in the presence of septic shock (45/466). Of the survivors, 31% were discharged with disability, including 24% of previously healthy children who survived with disability. Mortality and disability were independently associated with S. pneumoniae infections (mortality OR 4.1, 95% CI 1.1-16.0, P = 0.04; disability OR 5.4, 95% CI 1.8-15.8, P < 0.01) and illness severity as measured by Pediatric Index of Mortality (PIM2) score (mortality OR 2.8, 95% CI 1.3-6.1, P < 0.01; disability OR 3.4, 95% CI 1.8-6.4, P < 0.001). CONCLUSIONS: Despite widespread immunization campaigns, invasive bacterial disease remains responsible for substantial morbidity and mortality in critically ill children in high-income countries. Almost one third of sepsis survivors admitted to the PICU were discharged with some disability. More research is required to delineate the long-term outcome of pediatric sepsis and to identify interventional targets. Our findings emphasize the importance of improved early sepsis-recognition programs to address the high burden of disease

    A combined analysis technique for the search for fast magnetic monopoles with the MACRO detector

    Full text link
    We describe a search method for fast moving (β>5×103\beta > 5 \times 10^{-3}) magnetic monopoles using simultaneously the scintillator, streamer tube and track-etch subdetectors of the MACRO apparatus. The first two subdetectors are used primarily for the identification of candidates while the track-etch one is used as the final tool for their rejection or confirmation. Using this technique, a first sample of more than two years of data has been analyzed without any evidence of a magnetic monopole. We set a 90% CL upper limit to the local monopole flux of 1.5×1015cm2s1sr11.5 \times 10^{-15} cm^{-2} s^{-1} sr^{-1} in the velocity range 5×103β0.995 \times 10^{-3} \le \beta \le 0.99 and for nucleon decay catalysis cross section smaller than 1mb\sim 1 mb.Comment: 29 pages (12 figures). Accepted by Astroparticle Physic

    Final results of magnetic monopole searches with the MACRO experiment

    Get PDF
    We present the final results obtained by the MACRO experiment in the search for GUT magnetic monopoles in the penetrating cosmic radiation, for the range 4×105<β<14\times 10^{-5}< \beta < 1. Several searches with all the MACRO sub-detectors (i.e. scintillation counters, limited streamer tubes and nuclear track detectors) were performed, both in stand alone and combined ways. No candidates were detected and a 90% Confidence Level (C.L.) upper limit to the local magnetic monopole flux was set at the level of 1.4×10161.4\times 10^{-16} cm2^{-2} s1^{-1} sr1^{-1}. This result is the first experimental limit obtained in direct searches which is well below the Parker bound in the whole β\beta range in which GUT magnetic monopoles are expected.Comment: 12 pages, Latex, 9 figures and 2 Table

    The Observation of Up-going Charged Particles Produced by High Energy Muons in Underground Detectors

    Get PDF
    An experimental study of the production of up-going charged particles in inelastic interactions of down-going underground muons is reported, using data obtained from the MACRO detector at the Gran Sasso Laboratory. In a sample of 12.2 10^6 single muons, corresponding to a detector livetime of 1.55 y, 243 events are observed having an up-going particle associated with a down-going muon. These events are analysed to determine the range and emission angle distributions of the up-going particle, corrected for detection and reconstruction efficiency. Measurements of the muon neutrino flux by underground detectors are often based on the observation of through-going and stopping muons produced in νμ\nu_\mu interactions in the rock below the detector. Up-going particles produced by an undetected down-going muon are a potential background source in these measurements. The implications of this background for neutrino studies using MACRO are discussed.Comment: 18 pages, 9 figures. Accepted by Astrop. Physic

    Nuclearite search with the MACRO detector at Gran Sasso

    Full text link
    In this paper we present the results of a search for nuclearites in the penetrating cosmic radiation using the scintillator and track-etch subdetectors of the MACRO apparatus. The analyses cover the beta =v/c range at the detector depth (3700 hg/cm^2) 10^-5 < beta < 1; for beta = 2 x 10^-3 the flux limit is 2.7 x 10^-16 cm^-2 s^-1 sr^-1 for an isotropic flux of nuclearites, and twice this value for a flux of downgoing nuclearites.Comment: 16 pages, 4 Encapsulated Postscript figures, uses article.sty. Submitted to The European Physical Journal

    Atmospheric neutrino induced muons in the MACRO detector

    Get PDF
    A measurement of the flux of neutrino-induced muons using the MACRO detector is presented. Different event topologies, corresponding to different neutrino parent energies can be detected. The upward throughgoing muon sample is the larger event sample. The observed upward-throughgoing muons are 26% fewer than expected and the zenith angle distribution does not fit with the expected one. Assuming neutrino oscillations, both measurements suggest maximum mixing and Dm2 of a few times 10-3 eV2. The other samples are due to the internally produced events and to upward-going stopping muons. These data show a regular deficit of observed events in each angular bin, as expected assuming neutrino oscillations with maximum mixing, in agreement with the analysis of the upward-throughgoing muon sample.Comment: 7 pages 6 figures to appear in the proceedings of XVIII International Conference on Neutrino Physics and Astrophysics (Neutrino'98), Takayama, Japan 4-9 June, 199

    Hemorrhagic shock and encephalopathy syndrome – the markers for an early HSES diagnosis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The hemorrhagic shock and encephalopathy syndrome (HSES) is a devastating disease that affects young children. The outcomes of HSES patients are often fatal or manifesting severe neurological sequelae. We reviewed the markers for an early diagnosis of HSES.</p> <p>Methods</p> <p>We examined the clinical, biological and radiological findings of 8 patients (4 months to 9 years old) who met the HSES criteria.</p> <p>Results</p> <p>Although cerebral edema, disseminated intravascular coagulopathy (DIC), and multiple organ failure were seen in all 8 cases during their clinical courses, brain computed tomography (CT) scans showed normal or only slight edema in 5 patients upon admission. All 8 patients had normal platelet counts, and none were in shock. However, they all had severe metabolic acidosis, which persisted even after 3 hours (median base excess (BE), -7.6 mmol/L). And at 6 hours after admission (BE, -5.7 mmol/L) they required mechanical ventilation. Within 12 hours after admission, fluid resuscitation and vasopressor infusion for hypotension was required. Seven of the patients had elevated liver enzymes and creatine kinase (CK) upon admission. Twenty-four hours after admission, all 8 patients needed vasopressor infusion to maintain blood pressure.</p> <p>Conclusion</p> <p>CT scan, platelet count, hemoglobin level and renal function upon admission are not useful for an early diagnosis of HSES. However, the elevated liver enzymes and CK upon admission, hypotension in the early stage after admission with refractory acid-base disturbance to fluid resuscitation and vasopressor infusion are useful markers for an early HSES diagnosis and helpful to indicate starting intensive neurological treatment.</p

    New MACRO results on atmospheric neutrino oscillations

    Full text link
    The final results of the MACRO experiment on atmospheric neutrino oscillations are presented and discussed. The data concern different event topologies with average neutrino energies of ~3 and ~50 GeV. Multiple Coulomb Scattering of the high energy muons in absorbers was used to estimate the neutrino energy of each event. The angular distributions, the L/E_nu distribution, the particle ratios and the absolute fluxes all favour nu_mu --> nu_tau oscillations with maximal mixing and Delta m^2 =0.0023 eV^2. A discussion is made on the Monte Carlos used for the atmospheric neutrino flux. Some results on neutrino astrophysics are also briefly discussed.Comment: Invited Paper at the NANP03 Int. Conf., Dubna, 200
    corecore