1,938 research outputs found
White Paper: Measuring the Neutrino Mass Hierarchy
This white paper is a condensation of a report by a committee appointed
jointly by the Nuclear Science and Physics Divisions at Lawrence Berkeley
National Laboratory (LBNL). The goal of this study was to identify the most
promising technique(s) for resolving the neutrino mass hierarchy. For the most
part, we have relied on calculations and simulations presented by the
proponents of the various experiments. We have included evaluations of the
opportunities and challenges for these experiments based on what is available
already in the literature.Comment: White paper prepared for Snowmass-201
Opportunities and Challenges for Error Correction Scheme for Wireless Body Area Network: A Survey
This paper offers a review of different types of Error Correction Scheme (ECS) used in communication systems in general, which is followed by a summary of the IEEE standard for Wireless Body Area Network (WBAN). The possible types of channels and network models for WBAN are presented that are crucial to the design and implementation of ECS. Following that, a literature review on the proposed ECSs for WBAN is conducted based on different aspects. One aspect of the review is to examine what type of parameters are considered during the research work. The second aspect of the review is to analyse how the reliability is measured and whether the research works consider the different types of reliability and delay requirement for different data types or not. The review indicates that the current literatures do not utilize the constraints that are faced by WBAN nodes during ECS design. Subsequently, we put forward future research challenges and opportunities on ECS design and the implementation for WBAN when considering computational complexity and the energy-constrained nature of nodes
Search for extraterrestrial antineutrino sources with the KamLAND detector
We present the results of a search for extraterrestrial electron
antineutrinos ('s) in the energy range using the KamLAND detector. In an exposure of
4.53 kton-year, we identify 25 candidate events. All of the candidate events
can be attributed to background, most importantly neutral current atmospheric
neutrino interactions, setting an upper limit on the probability of B
solar 's converting into 's at
(90% C.L.), if we assume an undistorted shape. This limit
corresponds to a solar flux of or an event
rate of above the energy threshold
. The present data also allows us to set more
stringent limits on the diffuse supernova neutrino flux and on the annihilation
rates for light dark matter particles.Comment: 22 pages, 6 figure
Measurement of the 8B Solar Neutrino Flux with the KamLAND Liquid Scintillator Detector
We report a measurement of the neutrino-electron elastic scattering rate from
8B solar neutrinos based on a 123 kton-day exposure of KamLAND. The
background-subtracted electron recoil rate, above a 5.5 MeV analysis threshold
is 1.49+/-0.14(stat)+/-0.17(syst) events per kton-day. Interpreted as due to a
pure electron flavor flux with a 8B neutrino spectrum, this corresponds to a
spectrum integrated flux of 2.77+/-0.26(stat)+/-0.32(syst) x 10^6 cm^-2s^-1.
The analysis threshold is driven by 208Tl present in the liquid scintillator,
and the main source of systematic uncertainty is due to background from
cosmogenic 11Be. The measured rate is consistent with existing measurements and
with Standard Solar Model predictions which include matter enhanced neutrino
oscillation.Comment: 6 pages, 3 figure
CUORE and beyond: bolometric techniques to explore inverted neutrino mass hierarchy
The CUORE (Cryogenic Underground Observatory for Rare Events) experiment will
search for neutrinoless double beta decay of Te. With 741 kg of TeO
crystals and an excellent energy resolution of 5 keV (0.2%) at the region of
interest, CUORE will be one of the most competitive neutrinoless double beta
decay experiments on the horizon. With five years of live time, CUORE projected
neutrinoless double beta decay half-life sensitivity is y
at ( y at the 90% confidence level), which
corresponds to an upper limit on the effective Majorana mass in the range
40--100 meV (50--130 meV). Further background rejection with auxiliary light
detector can significantly improve the search sensitivity and competitiveness
of bolometric detectors to fully explore the inverted neutrino mass hierarchy
with Te and possibly other double beta decay candidate nuclei.Comment: Submitted to the Proceedings of TAUP 2013 Conferenc
Exploring the Neutrinoless Double Beta Decay in the Inverted Neutrino Hierarchy with Bolometric Detectors
Neutrinoless double beta decay (0nubb) is one of the most sensitive probes
for physics beyond the Standard Model, providing unique information on the
nature of neutrinos. In this paper we review the status and outlook for
bolometric 0nubb decay searches. We summarize recent advances in background
suppression demonstrated using bolometers with simultaneous readout of heat and
light signals. We simulate several configurations of a future CUORE-like
bolometer array which would utilize these improvements and present the
sensitivity reach of a hypothetical next-generation bolometric 0nubb
experiment. We demonstrate that a bolometric experiment with the isotope mass
of about 1 ton is capable of reaching the sensitivity to the effective Majorana
neutrino mass (|mee|) of order 10-20 meV, thus completely exploring the
so-called inverted neutrino mass hierarchy region. We highlight the main
challenges and identify priorities for an R&D program addressing them.Comment: 22 pages, 15 figures, submitted to EPJ
Validation of techniques to mitigate copper surface contamination in CUORE
In this article we describe the background challenges for the CUORE
experiment posed by surface contamination of inert detector materials such as
copper, and present three techniques explored to mitigate these backgrounds.
Using data from a dedicated test apparatus constructed to validate and compare
these techniques we demonstrate that copper surface contamination levels better
than 10E-07 - 10E-08 Bq/cm2 are achieved for 238U and 232Th. If these levels
are reproduced in the final CUORE apparatus the projected 90% C.L. upper limit
on the number of background counts in the region of interest is 0.02-0.03
counts/keV/kg/y depending on the adopted mitigation technique.Comment: 10 pages, 6 figures, 6 table
Search for Neutrinoless Double-Beta Decay of Te with CUORE-0
We report the results of a search for neutrinoless double-beta decay in a
9.8~kgyr exposure of Te using a bolometric detector array,
CUORE-0. The characteristic detector energy resolution and background level in
the region of interest are FWHM and ~counts/(keVkgyr), respectively. The
median 90%~C.L. lower-limit sensitivity of the experiment is and surpasses the sensitivity of previous searches. We find
no evidence for neutrinoless double-beta decay of Te and place a
Bayesian lower bound on the decay half-life, ~ at 90%~C.L. Combining CUORE-0 data with the 19.75~kgyr
exposure of Te from the Cuoricino experiment we obtain at 90%~C.L.~(Bayesian), the most stringent
limit to date on this half-life. Using a range of nuclear matrix element
estimates we interpret this as a limit on the effective Majorana neutrino mass,
-- .Comment: 6 pages, 5 figures, updated version as published in PR
Search for 14.4 keV solar axions from M1 transition of Fe-57 with CUORE crystals
We report the results of a search for axions from the 14.4 keV M1 transition
from Fe-57 in the core of the sun using the axio-electric effect in TeO2
bolometers. The detectors are 5x5x5 cm3 crystals operated at about 10 mK in a
facility used to test bolometers for the CUORE experiment at the Laboratori
Nazionali del Gran Sasso in Italy. An analysis of 43.65 kg d of data was made
using a newly developed low energy trigger which was optimized to reduce the
detectors energy threshold. An upper limit of 0.63 c kg-1 d-1 was established
at 95% C.L.. From this value, a lower bound at 95% C.L. was placed on the
Peccei-Quinn energy scale of fa >= 0.76 10**6 GeV for a value of S=0.55 for the
flavor-singlet axial vector matrix element. Bounds are given for the interval
0.15 < S < 0.55.Comment: 14 pages, 6 figures, submitted to JCA
CUORE-0 results and prospects for the CUORE experiment
With 741 kg of TeO2 crystals and an excellent energy resolution of 5 keV
(0.2%) at the region of interest, the CUORE (Cryogenic Underground Observatory
for Rare Events) experiment aims at searching for neutrinoless double beta
decay of 130Te with unprecedented sensitivity. Expected to start data taking in
2015, CUORE is currently in an advanced construction phase at LNGS. CUORE
projected neutrinoless double beta decay half-life sensitivity is 1.6E26 y at 1
sigma (9.5E25 y at the 90% confidence level), in five years of live time,
corresponding to an upper limit on the effective Majorana mass in the range
40-100 meV (50-130 meV). Further background rejection with auxiliary bolometric
detectors could improve CUORE sensitivity and competitiveness of bolometric
detectors towards a full analysis of the inverted neutrino mass hierarchy.
CUORE-0 was built to test and demonstrate the performance of the upcoming CUORE
experiment. It consists of a single CUORE tower (52 TeO2 bolometers of 750 g
each, arranged in a 13 floor structure) constructed strictly following CUORE
recipes both for materials and assembly procedures. An experiment its own,
CUORE-0 is expected to reach a sensitivity to the neutrinoless double beta
decay half-life of 130Te around 3E24 y in one year of live time. We present an
update of the data, corresponding to an exposure of 18.1 kg y. An analysis of
the background indicates that the CUORE performance goal is satisfied while the
sensitivity goal is within reach.Comment: 10 pages, 3 figures, to appear in the proceedings of NEUTRINO 2014,
26th International Conference on Neutrino Physics and Astrophysics, 2-7 June
2014, held at Boston, Massachusetts, US
- …