7 research outputs found

    Влияние длительного воздействия электромагнитного излучения частоты мобильного телефона на морфофункциональное состояние репродуктивной системы крыс-самцов и их потомства

    Get PDF
    The experiment established the long-term effects of low-intensity electromagnetic radiation from a mobile phone (EMR MP 1745 MHz, xpd = 7.5 ± 0.3 μW/cm2) in the offspring of male rats from parents, one of which was either subjected to a prolonged exposure of the investigated factor. A change in the sex ratio of the born offspring and a decrease in their body weight have been established. The analysis of the reproductive system of the offspring of males when they reached the age of 2 and 4 months, revealed significant impairments, with the most pronounced changes found in the offspring obtained from both the irradiated parents or when only the male was irradiated. These changes are manifested in the disruption of the normal functioning of the spermatogenic epithelium, namely, an intensification of the initial stage of spermatogenesis is noted, with a significant inhibition at the stage of spermatid transformation. A decrease in the number of mature germ cells – spermatozoa and a pronounced deterioration of their viability, as well as an increase in testosterone secretion is established. The revealed violations in the morphofunctional state of the reproductive system of the offspring suggest that the trans-generation effect of EMR exposure generated by cellular sources can be considered as a factor affecting the decline in the male fertility.В эксперименте были установлены отдаленные последствия влияния низкоинтенсивного электромагнитного излучения от мобильного телефона (ЭМИ МТ 1745 МГц, xППЭ = 7,5 ± 0,3 мкВт/см2) в потомстве крыс-самцов, рожденных от родителей, один из которых или оба были подвергнуты длительному воздействию исследуемого фактора. Установлено изменение соотношения полов у рожденного потомства и снижение их массы тела. Анализ состояния репродуктивной системы потомства самцов при достижении ими возраста 2 и 4 месяца выявил значительные нарушения, причем наиболее выраженные изменения отмечены у потомства, полученного от обоих облученных родителей или когда облучался только самец. Данные изменения проявляются в нарушении нормального функционирования сперматогенного эпителия, а именно имела место интенсификация начального этапа сперматогенеза при значительном его угнетении на стадии трансформации сперматид. Установлено снижение количества зрелых половых клеток – сперматозоидов и выраженное ухудшение их жизнеспособности, а также усиление секреции тестостерона. Выявленные нарушения в морфофункциональном состоянии репродуктивной системы потомства дают основание говорить о трансгенерационном эффекте воздействия ЭМИ, генерируемого источниками сотовой связи, что может быть фактором, влияющим на снижение мужской фертильности

    Анализ клеточного состава нативной трансплантационной аутосмеси, используемой для пластики дефектов костной ткани

    Get PDF
    The cell composition of native transplant autosmes (NTA) used for bone plastics was studied. The histological examination showed the fragments of bone beams with preserved osteoblasts, the foci of myeloid and lymphoid hematopoiesis and the fibrin deposits, which suggested the presence of MMSCs. Immunophenotyping of the NTA cell population revealed a high level of expression of the surface markers CD105, CD73, and CD90 characteristic for MMSC. DNA-flow cytometry of the bone dust confirmed almost complete preservation of graft viability on the 3rd day of culturing (97.7 % of live cells). The data of this study confirm the presence of the osteogenic, osteoinductive, and osteoconductive properties of the bone dust and emphasize the importance of a further study of this-type bone graft for use in surgical interventions.Проведено исследование клеточного состава нативной трансплантационной аутосмеси (НТА), используемой для костной пластики. Гистологическое исследование показало фрагменты костных балок с сохранившимися остеобластами, очаги миелоидного и лимфоидного кроветворения и отложения фибрина, что позволило предположить наличие мультипотентных мезенхимальных стромальных клеток (ММСК). При имммунофенотипировании популяции клеток НТА выявлен высокий уровень экспрессии поверхностных маркеров CD105, CD73 и CD90, характерных для ММСК. ДНК-проточная цитофлоурометрия костной аутосмеси подтвердила практически полное сохранение жизнеспособности трансплантата на третьи сутки культивирования (97,7 % живых клеток). Полученные данные свидетельствуют о наличии у нативной трансплантационной аутосмеси остеогенных, остеоиндуктивных, остеокондуктивных свойств и обосновывают дальнейшее ее исследование с целью использования в качестве аутотрансплантата при хирургических вмешательствах

    ЧУВСТВИТЕЛЬНОСТЬ КЛЕТОК КРОВИ И ЭПИДИДИМАЛЬНЫХ СПЕРМАТОЗОИДОВ КРЫС К ВОЗДЕЙСТВИЮ МАГНИТНОГО ПОЛЯ ПРОМЫШЛЕННОЙ ЧАСТОТЫ (50 Гц)

    Get PDF
    The article discusses the data on the long-time effect of low frequency magnetic fields (IF MF 50 Hz, 0.4 mT, 4h/day, 5 days/week, 26 days) on blood cells and spermatozoa of Wistar rats. It was determined that at different times after exposure (3th, 15th and 30th days) the changes in different quantitative and qualitative indicators of test cells were revealed, some of which are kept in 30 days after exposure. В сообщении обсуждаются данные исследований длительного воздействия магнитного поля промышленной частоты (МП ПЧ 50 Гц, 0,4 мT, 4 ч/день, 5 дней в неделю, суммарное количество 26 дней) на клетки крови и эпидидимальные сперматозоиды крыс Вистар. Установлено, что в различные сроки после воздействия (3-и, 15-е и 30-е сутки) выявляются изменения различных количественных и качественных показателей исследуемых клеток, некоторые из которых сохраняются в отдаленном периоде (30-е cутки после экспозиции).

    EFFECTS OF LONG-TERM ELECTROMAGNETIC RADIATION OF MOBILE PHONES (1745 MHZ) ON BLOOD AND REPRODUCTIVE SYSTEM OF MALE RATS

    No full text
    The article presents data of research on the long-term exposure (two or three months) effect of mobile phone EMF (1745 MHz) in the immediate (1st day) and remote (30th day) period on the number of leukocytes and leukocyte blood elements and indices of the reproductive system of male rats. It was established that on the 1st day after EMF exposure from mobile phones (1745 MHz) notes some deviations hematological parameters of control, particularly important for the number of granulocytes after 3 months of exposure, observed disturbance spermatogenesis, as well as reducing the number of epididymal spermatozoa and drop their viability. By the 30th day revealed changes in the parameters studied mostly normalized, with the exception of significant fall viability of mature germ cells at 60-day and the number of granulocytes in the 90-day exposure

    Effects of long–term electromagnetic radiation of mobile phones (1745 MHz) on blood and reproductive system of male rats

    No full text
    Приведены данные исследований о влиянии длительной экспозиции электромагнитного поля мобильного телефона (1745 МГц) в ближайшем (1-е сутки) и отдаленном (30-е сутки) периодах на число лейкоцитов и лейкоцитарных элементов крови и показатели репродуктивной системы крыс-самцов. Установлено, что на 1-е сутки после воздействия ЭМП от мобильного телефона (1745 МГц) отмечаются некоторые отклонения гематологических показателей от контроля, особенно значимые для числа гранулоцитов после 3-месячного облучения; наблюдаются нарушения процесса сперматогенеза, а также снижение количества эпидидимальных сперматозоидов и падение их жизнеспособности. К 30-м суткам выявленные изменения исследуемых показателей в основном нормализуются, за исключением достоверного падения жизнеспособности зрелых половых клеток при 60-дневной и числа гранулоцитов при 90-дневной экспозиции. The article presents data of research on the long-term exposure (two or three months) effect of mobile phone EMF (1745 MHz) in the immediate (1st day) and remote (30th day) period on the number of leukocytes and leukocyte blood elements and indices of the reproductive system of male rats. It was established that on the 1st day after EMF exposure from mobile phones (1745 MHz) notes some deviations hematological parameters of control, particularly important for the number of granulocytes after 3 months of exposure, observed disturbance spermatogenesis, as well as reducing the number of epididymal spermatozoa and drop their viability. By the 30th day revealed changes in the parameters studied mostly normalized, with the exception of significant fall viability of mature germ cells at 60-day and the number of granulocytes in the 90-day exposure

    Effects of long–term electromagnetic radiation of mobile phones (1745 MHz) on blood and reproductive system of male rats

    No full text
    Приведены данные исследований о влиянии длительной экспозиции электромагнитного поля мобильного телефона (1745 МГц) в ближайшем (1-е сутки) и отдаленном (30-е сутки) периодах на число лейкоцитов и лейкоцитарных элементов крови и показатели репродуктивной системы крыс-самцов. Установлено, что на 1-е сутки после воздействия ЭМП от мобильного телефона (1745 МГц) отмечаются некоторые отклонения гематологических показателей от контроля, особенно значимые для числа гранулоцитов после 3-месячного облучения; наблюдаются нарушения процесса сперматогенеза, а также снижение количества эпидидимальных сперматозоидов и падение их жизнеспособности. К 30-м суткам выявленные изменения исследуемых показателей в основном нормализуются, за исключением достоверного падения жизнеспособности зрелых половых клеток при 60-дневной и числа гранулоцитов при 90-дневной экспозиции. The article presents data of research on the long-term exposure (two or three months) effect of mobile phone EMF (1745 MHz) in the immediate (1st day) and remote (30th day) period on the number of leukocytes and leukocyte blood elements and indices of the reproductive system of male rats. It was established that on the 1st day after EMF exposure from mobile phones (1745 MHz) notes some deviations hematological parameters of control, particularly important for the number of granulocytes after 3 months of exposure, observed disturbance spermatogenesis, as well as reducing the number of epididymal spermatozoa and drop their viability. By the 30th day revealed changes in the parameters studied mostly normalized, with the exception of significant fall viability of mature germ cells at 60-day and the number of granulocytes in the 90-day exposure

    ЭФФЕКТЫ ДЛИТЕЛЬНОГО ЭЛЕКТРОМАГНИТНОГО ВОЗДЕЙСТВИЯ МОБИЛЬНОГО ТЕЛЕФОНА (1745 МГЦ) НА КРОВЬ И РЕПРОДУКТИВНУЮ СИСТЕМУ КРЫС-САМЦОВ

    No full text
    The article presents data of research on the long-term exposure (two or three months) effect of mobile phone EMF (1745 MHz) in the immediate (1st day) and remote (30th day) period on the number of leukocytes and leukocyte blood elements and indices of the reproductive system of male rats. It was established that on the 1st day after EMF exposure from mobile phones (1745 MHz) notes some deviations hematological parameters of control, particularly important for the number of granulocytes after 3 months of exposure, observed disturbance spermatogenesis, as well as reducing the number of epididymal spermatozoa and drop their viability. By the 30th day revealed changes in the parameters studied mostly normalized, with the exception of significant fall viability of mature germ cells at 60-day and the number of granulocytes in the 90-day exposure.Приведены данные исследований о влиянии длительной экспозиции электромагнитного поля мобильного телефона (1745 МГц) в ближайшем (1-е сутки) и отдаленном (30-е сутки) периодах на число лейкоцитов и лейкоцитарных элементов крови и показатели репродуктивной системы крыс-самцов. Установлено, что на 1-е сутки после воздействия ЭМП от мобильного телефона (1745 МГц) отмечаются некоторые отклонения гематологических показателей от контроля, особенно значимые для числа гранулоцитов после 3-месячного облучения; наблюдаются нарушения процесса сперматогенеза, а также снижение количества эпидидимальных сперматозоидов и падение их жизнеспособности. К 30-м суткам выявленные изменения исследуемых показателей в основном нормализуются, за исключением достоверного падения жизнеспособности зрелых половых клеток при 60-дневной и числа гранулоцитов при 90-дневной экспозиции
    corecore