Novel Single Photon Detectors for UV Imaging
There are several applications which require high position resolution UV
imaging. For these applications we have developed and successfully tested a new
version of a 2D UV single photon imaging detector based on a microgap RPC. The
main features of such a detectors is the high position resolution - 30 micron
in digital form and the high quantum efficiency (1-8% in the spectral interval
of 220-140 nm). Additionally, they are spark- protected and can operate without
any feedback problems at high gains, close to a streamer mode. In attempts to
extend the sensitivity of RPCs to longer wavelengths we have successfully
tested the operation of the first sealed parallel-plate gaseous detectors with
CsTe photocathodes. Finally, the comparison with other types of photosensitive
detectors is given and possible fields of applications are identified.Comment: Presented at the 5th International Workshop on RICH detectors Playa
del Carmen, Mexico, November 200
Heat balance model for long-term prediction of the thermal regime of a subway tunnel and surrounding soil
For a long-term forecast of the average air temperature in a metro tunnel and
surrounding soil, heat balance conditions are modeled in a system that includes
two parallel tunnels, a near-tunnels underground space, the earth's surface and
atmospheric air with seasonal temperature variation. It is assumed that the air
in the tunnels is well mixed, and the thermal effect of ventilation is taken
into account by replacing the air in the tunnels with atmospheric air. The
system of heat balance equations is solved numerically by the finite element
method. A numerical analysis of the influences of the model parameters on the
average temperature in the tunnels and surrounding soil is carried out. The
dimensions of the soil region with an elevated temperature, located between the
tunnels, are estimated.Comment: 28 pages, 9 figure
First observation of Cherenkov rings with a large area CsI-TGEM-based RICH prototype
We have built a RICH detector prototype consisting of a liquid C6F14 radiator
and six triple Thick Gaseous Electron Multipliers (TGEMs), each of them having
an active area of 10x10 cm2. One triple TGEM has been placed behind the liquid
radiator in order to detect the beam particles, whereas the other five have
been positioned around the central one at a distance to collect the Cherenkov
photons. The upstream electrode of each of the TGEM stacks has been coated with
a 0.4 micron thick CsI layer.
In this paper, we will present the results from a series of laboratory tests
with this prototype carried out using UV light, 6 keV photons from 55Fe and
electrons from 90Sr as well as recent results of tests with a beam of charged
pions where for the first time Cherenkov Ring images have been successfully
recorded with TGEM photodetectors. The achieved results prove the feasibility
of building a large area Cherenkov detector consisting of a matrix of TGEMs.Comment: Presented at the International Conference NDIP-11, Lyon,July201
The development of gaseous detectors with solid photocathodes for low temperature
There are several applications and fundamental research areas which require
the detection of VUV light at cryogenic temperatures. For these applications we
have developed and successfully tested special designs of gaseous detectors
with solid photocathodes able to operate at low temperatures: sealed gaseous
detectors with MgF2 windows and windowless detectors. We have experimentally
demonstrated, that both primary and secondary (due to the avalanche
multiplication inside liquids) scintillation lights could be recorded by
photosensitive gaseous detectors. The results of this work may allow one to
significantly improve the operation of some noble liquid gas TPCs.Comment: Presented at the X Vienna Conference on Instumentation, Vienna,
February 200
DBSolve Optimum: a software package for kinetic modeling which allows dynamic visualization of simulation results
<p>Abstract</p> <p>Background</p> <p>Systems biology research and applications require creation, validation, extensive usage of mathematical models and visualization of simulation results by end-users. Our goal is to develop novel method for visualization of simulation results and implement it in simulation software package equipped with the sophisticated mathematical and computational techniques for model development, verification and parameter fitting.</p> <p>Results</p> <p>We present mathematical simulation workbench DBSolve Optimum which is significantly improved and extended successor of well known simulation software DBSolve5. Concept of "dynamic visualization" of simulation results has been developed and implemented in DBSolve Optimum. In framework of the concept graphical objects representing metabolite concentrations and reactions change their volume and shape in accordance to simulation results. This technique is applied to visualize both kinetic response of the model and dependence of its steady state on parameter. The use of the dynamic visualization is illustrated with kinetic model of the Krebs cycle.</p> <p>Conclusion</p> <p>DBSolve Optimum is a user friendly simulation software package that enables to simplify the construction, verification, analysis and visualization of kinetic models. Dynamic visualization tool implemented in the software allows user to animate simulation results and, thereby, present them in more comprehensible mode. DBSolve Optimum and built-in dynamic visualization module is free for both academic and commercial use. It can be downloaded directly from <url>http://www.insysbio.ru</url>.</p
- âŠ