57 research outputs found
Self-Applied Electrode Set Provides a Clinically Feasible Solution Enabling EEG Recording in Home Sleep Apnea Testing
Home sleep apnea testing (HSAT) without electroencephalography (EEG) recording is increasingly used as an alternative to in-laboratory polysomnography for the diagnosis of obstructive sleep apnea (OSA). However, without EEG, electrooculography (EOG), and chin electromyography (EMG) recordings, the OSA severity may be significantly underestimated. Although several ambulatory EEG systems have been recently introduced, no patient-applied systems including EEG, EOG, and chin EMG suitable for home polysomnography are currently in clinical use. We have recently developed and pre-clinically tested a self-applied ambulatory electrode set (AES), consisting of frontal EEG, EOG, and EMG, in subjects with possible sleep bruxism. Now, in this clinical feasibility study, we investigated the signal scorability and usability of the AES as a self-administered sleep assessment approach supplementing the conventional HSAT device. We also investigated how the diagnostic parameters and OSA severity changed when utilizing the AES. Thirty-eight patients (61 % male, 25-78 years) with a clinical suspicion of OSA conducted a single-night, self-administered HSAT with a portable polysomnography device (Nox A1, Nox Medical, Reykjavik, Iceland) supplemented with AES. Only one AES recording failed. The use of AES signals in data analysis significantly affected the median apnea-hypopnea index (AHI), increasing it from 9.4 to 12.7 events/h (p < 0.001) compared to the conventional HSAT. Also, in eight patients, the OSA severity class changed to one class worse. Perceived ease of use was well in line with that previously found among healthy volunteers. These results suggest that the AES provides an easy, clinically feasible solution to record EEG as a part of conventional HSAT.Peer reviewe
Success Rate and Technical Quality of Home Polysomnography With Self-Applicable Electrode Set in Subjects With Possible Sleep Bruxism
Using sleep laboratory polysomnography (PSG) is restricted for the diagnosis of only the most severe sleep disorders due to its low availability and high cost. Home PSG is more affordable, but applying conventional electroencephalography (EEG) electrodes increases its overall complexity and lowers the availability. Simple, self-administered single-channel EEG monitors on the other hand suffer from poor reliability. In this study, we aimed to quantify the reliability of self-administrated home PSG recordings conducted with a newly designed ambulatory electrode set (AES) that enables multichannel EEG, electrooculography, electromyography, and electrocardiography recordings. We assessed the sleep study success rate and technical quality of the recordings performed in subjects with possible sleep bruxism (SB). Thirty-two females and five males aged 39.6 +/- 11.6 years (mean +/- SD) with self-reported SB were recruited in the study. Self-administrated home PSG recordings with two AES designs were conducted (n = 19 and 21). The technical quality of the recordings was graded based on the proportion of interpretable data. Technical failure rate for AES (both designs) was 5% and SB was scorable for 96.9% of all recorded data. Only one recording failed due to mistakes in self-applying the AES. We found that the proportion of good quality self-administrated EEG recordings is significantly higher when multiple channels are used compared to using a single channel. Sleep study success rates and proportion of recordings with high quality interpretable data from EEG channels of AES were comparable to that of conventional home PSG. Self-applicable AES has potential to become a reliable tool for widely available home PSG.Peer reviewe
Deep Learning Enables Accurate Automatic Sleep Staging Based on Ambulatory Forehead EEG
We have previously developed an ambulatory electrode set (AES) for the measurement of electroencephalography (EEG), electrooculography (EOG), and electromyography (EMG). The AES has been proven to be suitable for manual sleep staging and self-application in in-home polysomnography (PSG). To further facilitate the diagnostics of various sleep disorders, this study aimed to utilize a deep learning-based automated sleep staging approach for EEG signals acquired with the AES. The present neural network architecture comprises a combination of convolutional and recurrent neural networks previously shown to achieve excellent sleep scoring accuracy with a single standard EEG channel (F4-M1). In this study, the model was re-trained and tested with 135 EEG signals recorded with AES. The recordings were conducted for subjects suspected of sleep apnea or sleep bruxism. The performance of the deep learning model was evaluated with 10-fold cross-validation using manual scoring of the AES signals as a reference. The accuracy of the neural network sleep staging was 79.7% (kappa = 0.729) for five sleep stages (W, N1, N2, N3, and R), 84.1% (kappa = 0.773) for four sleep stages (W, light sleep, deep sleep, R), and 89.1% (kappa = 0.801) for three sleep stages (W, NREM, R). The utilized neural network was able to accurately determine sleep stages based on EEG channels measured with the AES. The accuracy is comparable to the inter-scorer agreement of standard EEG scorings between international sleep centers. The automatic AES-based sleep staging could potentially improve the availability of PSG studies by facilitating the arrangement of self-administrated in-home PSGs.Peer reviewe
Towards a Deeper Understanding of Sleep Stages through their Representation in the Latent Space of Variational Autoencoders
Artificial neural networks show great success in sleep stage classification, with an accuracy comparable to human scoring. While their ability to learn from labelled electroencephalography (EEG) signals is widely researched, the underlying learning processes remain unexplored. Variational autoencoders can capture the underlying meaning of data by encoding it into a low-dimensional space. Regularizing this space furthermore enables the generation of realistic representations of data from latent space samples. We aimed to show that this model is able to generate realistic sleep EEG. In addition, the generated sequences from different areas of the latent space are shown to have inherent meaning. The current results show the potential of variational autoencoders in understanding sleep EEG data from the perspective of unsupervised machine learning
Low-Dose Doxycycline Treatment Normalizes Levels of Some Salivary Metabolites Associated with Oral Microbiota in Patients with Primary Sjögren’s Syndrome
Saliva is a complex oral fluid, and plays a major role in oral health. Primary Sjögren’s syndrome (pSS), as an autoimmune disease that typically causes hyposalivation. In the present study, salivary metabolites were studied from stimulated saliva samples (n = 15) of female patients with pSS in a group treated with low-dose doxycycline (LDD), saliva samples (n = 10) of non-treated female patients with pSS, and saliva samples (n = 14) of healthy age-matched females as controls. Saliva samples were analyzed with liquid chromatography mass spectrometry (LC-MS) based on the non-targeted metabolomics method. The saliva metabolite profile differed between pSS patients and the healthy control (HC). In the pSS patients, the LDD treatment normalized saliva levels of several metabolites, including tyrosine glutamine dipeptide, phenylalanine isoleucine dipeptide, valine leucine dipeptide, phenylalanine, pantothenic acid (vitamin B5), urocanic acid, and salivary lipid cholesteryl palmitic acid (CE 16:0), to levels seen in the saliva samples of the HC. In conclusion, the data showed that pSS is associated with an altered saliva metabolite profile compared to the HC and that the LLD treatment normalized levels of several metabolites associated with dysbiosis of oral microbiota in pSS patients. The role of the saliva metabolome in pSS pathology needs to be further studied to clarify if saliva metabolite levels can be used to predict or monitor the progress and treatment of pSS
- …