Normal aortic diameters within the Mexican population and the impact of gender and ethnicity
Background: There is a lack of studies describing the normal size of the aorta in Mexican population. Objective: To analyze aortic measurements in Mexican patients and to compared them with patients from five different countries. Methods: Measurements of the aorta were divided in Mexicans and controls. Comparisons between ethnicities and groups were performed using Mann Whitney rank sum test. Results: The registry included 166 patients, 106 (63.8%) were enrolled in Mexico and 60 (36.1%) in the control group. Mexican patients had smaller aortic diameters compared to the control group, at the level of the right renal artery ostium, inferior mesenteric artery, and aortic bifurcation. The Hispanic population had significantly smaller aortic diameters from the level of the celiac artery to the aortic bifurcation. Conclusion: The normal aortic diameters in the Mexican population are smaller compared to other countries.</p
Recommended from our members
Results of the Galician registry in the treatment of complex aortoiliac aneurysms with GORE ® EXCLUDER ® Iliac Branch Endoprosthesis (GALIBER)
Objective
The objective of this study is to report the medium-term results of GORE
®
EXCLUDER
®
Iliac Branch Endoprosthesis (IBE, W. L. Gore & Associates, Flagstaff, Ariz) for the treatment of aortoiliac aneurysms by using the GALIBER registry.
Methods
Patients with aortoiliac or isolated common iliac/hypogastric aneurysms treated with Iliac Branch Endoprosthesis device between January 2014 and May 2019 were prospectively collected from 5 centers. Demographic, clinical, and radiologic data were extracted from electronic databases. Technical success was defined as successful implantation of the Iliac Branch Endoprosthesis device with exclusion of aortoiliac aneurysm, as well as patency of Iliac Branch Endoprosthesis in the follow-up. Iliac Branch Endoprosthesis patency was evaluated by Doppler ultrasound and/or computed tomography based on the protocol of each participant center. Follow-up was 731 days +/− 499.
Results
Between January 2014 and May 2019, 105 iliac arteries were treated with GORE
®
IBE device, in 81 patients (79 men, two women; mean age 71, range 52–91). Only seven patients (8.6%) were symptomatic. 60 patients (74%) had aortic and iliac enlargement. Thirty-three patients presented bilateral iliac aneurysms (40.7%): In twenty-four (29.6%) patients, an Iliac Branch Endoprosthesis device was implanted in both sides, and in nine patients (11.1%), one Iliac Branch Endoprosthesis was used with the embolization of the contralateral hypogastric artery. Technical success was achieved in the 99% (104/105 iliac branch device implanted). There were no procedural deaths or type I or III intraoperative endoleaks observed. During the follow-up (range 55–1789 days), 28 (34.5%) type II endoleaks were observed and one (1.2%) type Ia was observed. The patency of the hypogastric arteries treated with the iliac branch device was 98.1% during the follow-up (range 55–1789 days). In 30% of the patients with contralateral hypogastric embolization, some kind of complications was observed in the embolizated side: one developed ischemic colitis and two buttock claudication.
Conclusions
Preservation of internal iliac artery with the Iliac Branch Endoprosthesis device can be performed safely with excellent technical success and good medium-term patency rates. These results support hypogastric preservation whenever possible to prevent ischemic complications
Incidence and prognostic factors related to major adverse cerebrovascular events in patients with complex aortic diseases treated by the chimney technique
Objective: Endovascular aneurysm repair (EVAR) with the chimney technique (ch-EVAR) has been used for the treatment of aortic aneurysms as an alternative approach to fenestrated endografting or open repair. Nonetheless, the need for an upper extremity arterial access may contribute to a higher risk for periprocedural cerebrovascular events. This study reports on the perioperative cerebral and major adverse cardiac and cerebrovascular events (MACCE) after ch-EVAR. Methods: The PERICLES registry (PERformance of the chImney technique for the treatment of Complex aortic pathoLogiES) is an international, retrospective multicenter study evaluating the performance of ch-EVAR for the treatment of complex aortic pathologies. For the purpose of the current analysis, 425 patients treated by ch-EVAR between 2008 and 2014 were included. The primary outcome of this analysis was the incidence of procedure related cerebrovascular events defined as transient ischemic attack or stroke. The secondary end point was in-hospital MACCE, including acute coronary syndrome, stroke, and death of any cause. Results: The incidence of clinical relevant cerebrovascular events was 1.9% (8/425). A postoperative transient ischemic attack was observed in four patients (0.95%) and a stroke in additional four (0.95%). Three patients died during the hospital stay secondary to sequelae from postoperative stroke. A prior history of stroke/transient ischemic attack, atrial fibrillation, previous carotid revascularization, or known carotid artery disease did not significantly increase the risk for adverse neurologic events. The overall MACCE rate amounted to 8.5% (36/425). Logistic regression analysis revealed that the use of bilateral upper extremity access (odds ratio [OR], 2.79; 95% confidence interval [CI], 1.04-7.45]), aneurysm rupture (OR, 5.33; 95% CI, 1.74-16.33), and a prolonged operation time (>290 minutes; OR, 1.005; 95% CI, 1.001-1.008) were associated with a significantly increased risk for MACCE. Conclusions: This analysis demonstrates that ch-EVAR is associated with a relatively low rate of cerebrovascular events. However, a postoperative stroke is associated with increased mortality. Ruptured aneurysms, bilateral upper extremity access as in case of multiple chimney graft placement, and longer operative times were identified as independent risk factors for MACCE