47 research outputs found
Heme Oxygenase-1 Expression Affects Murine Abdominal Aortic Aneurysm Progression.
Heme oxygenase-1 (HO-1), the rate-limiting enzyme in heme degradation, is a cytoprotective enzyme upregulated in the vasculature by increased flow and inflammatory stimuli. Human genetic data suggest that a diminished HO-1 expression may predispose one to abdominal aortic aneurysm (AAA) development. In addition, heme is known to strongly induce HO-1 expression. Utilizing the porcine pancreatic elastase (PPE) model of AAA induction in HO-1 heterozygous (HO-1+/-, HO-1 Het) mice, we found that a deficiency in HO-1 leads to augmented AAA development. Peritoneal macrophages from HO-1+/- mice showed increased gene expression of pro-inflammatory cytokines, including MCP-1, TNF-alpha, IL-1-beta, and IL-6, but decreased expression of anti-inflammatory cytokines IL-10 and TGF-beta. Furthermore, treatment with heme returned AAA progression in HO-1 Het mice to a wild-type profile. Using a second murine AAA model (Ang II-ApoE-/-), we showed that low doses of the HMG-CoA reductase inhibitor rosuvastatin can induce HO-1 expression in aortic tissue and suppress AAA progression in the absence of lipid lowering. Our results support those studies that suggest that pleiotropic statin effects might be beneficial in AAA, possibly through the upregulation of HO-1. Specific targeted therapies designed to induce HO-1 could become an adjunctive therapeutic strategy for the prevention of AAA disease
Monitoring tissue oxygenation index using near-infrared spectroscopy during pre-hospital resuscitation among out-of-hospital cardiac arrest patients: a pilot study
BACKGROUND: Tissue oxygenation index (TOI) using the near infrared spectroscopy (NIRS) has been demonstrated as a useful indicator to predict return of spontaneous circulation (ROSC) among out-of-hospital cardiac arrest (OHCA) patients in hospital setting. However, it has not been widely examined based on pre-hospital setting.
METHODS: In this prospective observational study, we measured TOI in pre-hospital setting among OHCA patients receiving cardio-pulmonary resuscitation (CPR) during ambulance transportation between 2017 and 2018. Throughout the pre-hospital CPR procedure, TOI was continuously measured. The study population was divided into two subgroups: ROSC group and non-ROSC group.
RESULTS: Of the 81 patients included in the final analysis, 26 achieved ROSC and 55 did not achieve ROSC. Patients in the ROSC group were significantly younger, had higher ∆TOI (changes in TOI) (5.8 % vs. 1.3 %; p \u3c 0.01), and were more likely to have shockable rhythms and event witnessed than patients in the non-ROSC group. ∆TOI cut-off value of 5 % had highest sensitivity (65.4 %) and specificity (89.3 %) for ROSC. Patients with a cut-off value ≤-2.0 % did not achieve ROSC and while all OHCA patient with a cut-off value ≥ 8.0 % achieved ROSC. In addition, ROSC group had stronger positive correlation between mean chest compression rate and ∆TOI (r = 0.82) than non-ROSC group (r = 0.50).
CONCLUSIONS: This study suggests that ∆ TOI could be a useful indicator to predict ROSC in a pre-hospital setting
The hardest X-ray source in the ASCA Large Sky Survey: Discovery of a new type 2 Seyfert
We present results of ASCA deep exposure observations of the hardest X-ray
source discovered in the ASCA Large Sky Survey (LSS) project, designated as AX
J131501+3141. We extract its accurate X-ray spectrum, taking account of the
contamination from a nearby soft source (AX J131502+3142), separated only by
1'. AX J131501+3141 exhibits a large absorption of NH = (6 +4 -2)x 10^22 H/cm^2
with a photon index \Gamma = 1.5 +0.7 -0.6. The 2--10 keV flux was about 5 x
10^-13 erg/s/cm^2 and was time variable by a factor of 30% in 0.5 year. From
the highly absorbed X-ray spectrum and the time variability, as well as the
results of the optical follow-up observations (Akiyama et al. 1998,
astro-ph/9801173), we conclude that AX J131501+3141 is a type 2 Seyfert galaxy.
Discovery of such a low flux and highly absorbed X-ray source could have a
significant impact on the origin of the cosmic X-ray background.Comment: 16 pages, 6 figures, requires AAS Latex macro v4.0, to appear in The
Astrophysical Journal, text and figures also available at
http://www-cr.scphys.kyoto-u.ac.jp/member/sakano/work/paper/index-e.htm
The Japanese space gravitational wave antenna; DECIGO
DECi-hertz Interferometer Gravitational wave Observatory (DECIGO) is the future
Japanese space gravitational wave antenna. DECIGO is expected to open a new window of
observation for gravitational wave astronomy especially between 0.1 Hz and 10 Hz, revealing
various mysteries of the universe such as dark energy, formation mechanism of supermassive
black holes, and inflation of the universe. The pre-conceptual design of DECIGO consists of
three drag-free spacecraft, whose relative displacements are measured by a differential Fabry–
Perot Michelson interferometer. We plan to launch two missions, DECIGO pathfinder and pre-
DECIGO first and finally DECIGO in 2024
DECIGO pathfinder
DECIGO pathfinder (DPF) is a milestone satellite mission for DECIGO (DECi-hertz Interferometer Gravitational wave Observatory) which is a future space gravitational wave antenna. DECIGO is expected to provide us fruitful insights into the universe, in particular about dark energy, a formation mechanism of supermassive black holes, and the inflation of the universe. Since DECIGO will be an extremely large mission which will formed by three drag-free spacecraft with 1000m separation, it is significant to gain the technical feasibility of DECIGO before its planned launch in 2024. Thus, we are planning to launch two milestone missions: DPF and pre-DECIGO. The conceptual design and current status of the first milestone mission, DPF, are reviewed in this article
The status of DECIGO
DECIGO (DECi-hertz Interferometer Gravitational wave Observatory) is the planned Japanese space gravitational wave antenna, aiming to detect gravitational waves from astrophysically and cosmologically significant sources mainly between 0.1 Hz and 10 Hz and thus to open a new window for gravitational wave astronomy and for the universe. DECIGO will consists of three drag-free spacecraft arranged in an equilateral triangle with 1000 km arm lengths whose relative displacements are measured by a differential Fabry-Perot interferometer, and four units of triangular Fabry-Perot interferometers are arranged on heliocentric orbit around the sun. DECIGO is vary ambitious mission, we plan to launch DECIGO in era of 2030s after precursor satellite mission, B-DECIGO. B-DECIGO is essentially smaller version of DECIGO: B-DECIGO consists of three spacecraft arranged in an triangle with 100 km arm lengths orbiting 2000 km above the surface of the earth. It is hoped that the launch date will be late 2020s for the present
Three-rods test as drivers' license vision test from the viewpoint of reproducibility, eye deviation, and functional visual acuity
Background: Three-rods test is required as depth perception vision test to obtain motor vehicle license to drive taxies, buses, and trucks in Japan. Functional visual acuity is measured automatically by successive visual target presentation in a fixed period of time. This study examined three-rods test from the viewpoint of reproducibility, eye deviation, and functional visual acuity to assess the feasibility for drivers' license vision test. Methods: At three-rods test, a central rod was moved at the speed of 50 mm/sec forward and backward automatically against two fixed rods on both sides inside an illuminated box. An examinee at the distance of 2.5 m observed the rods inside the box from a small window and pushed a button to stop the central rod in alignment with the fixed rods. Erred distance of the central rod from the fixed rods as a mean of 4 measurements was used. At functional visual acuity test, an examinee moved a joystick to the same direction as Landolt-C opening as a visual target which was sequentially presented every 2 seconds for 30 times in 1 minute. Results: The mean erred distance of three-rods test was reproducible between two tests done on separate occasions (n = 44, ρ = 0.679, P < 0.0001, Spearman rank correlation). Exophoria induced by wearing 4-prism-diopter base-out prism did not significantly influence the mean erred distance while vertical diplopia induced by wearing 4-prism-diopter base-up prism disrupted the measurement (n = 9). The mean erred distance of three-rods test was better correlated with functional visual acuity tested with both eyes open than with conventional visual acuity with both eyes open (n = 17, ρ = 0.2 versus ρ = 0.179). Conclusion: In the context of the small sample size in the present study, the three-rods test was reproducible, and testable in the presence of phoria, but not testable in diplopia, indicating the feasibility as a depth perception vision test